Honeywell VISTA-40 manual Zone List Programming, Start Partn ANY Partition, Unit Code

Page 24

PROMPTEXPLANATION

02 START: PARTN

 

ANY PARTITION

0

If the starting event will be limited to occurring on a specific partition, enter the partition number (1-2) in which the start event will occur. Enter 0 for any partition.

Press [] to continue.

Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de- activate the relay.

PROMPTEXPLANATION

 

02

STOP: ZN LIST

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

 

02

STOP: ZN TYPE

 

 

NO RESPONSE

00

 

 

 

 

 

 

 

 

 

 

02

STOP: PARTN

 

 

ANY PARTITION

0

 

 

 

 

 

 

 

 

 

 

02

RESTRICTION

 

 

1=YES 0=NO

0

 

 

 

 

 

 

 

 

 

 

02

RELAY TYPE

 

 

V-PLEX

0

 

 

 

 

 

 

 

 

 

 

02

ECP ADDRESS

 

 

 

 

00

 

 

 

 

 

 

 

 

 

 

 

02 MODULE RELAY#

 

 

0

 

 

 

 

 

 

 

02 HOUSE CODE

 

 

A

00

 

If a zone list is being used to stop this relay action, enter the zone list number, 1-4. The restore of a zone on the zone list stops the relay. If a zone list is not being used, enter 0.

Press [] to continue.

If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the Choices for Start/Stop System Operation chart.

Press [] to continue.

This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-2for specific partition number.

Press [] to continue.

The system may have some devices that are not intended to be under end user control, such as relays activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay. Press [] to continue.

Enter 1 for (ECP) relay modules (4204). Enter 2 for X-10 devices.

Press [] to continue.

If you selected 1 (4204), enter the actual module’s address (01-15)as set by its DIP switches. Up to 2 modules can be installed in a system.

Press [] to continue.

For 4204 Relay Outputs, enter the specific relay number on that module (1-4).

Press [] to continue.

The keypad will display the Start and Stop summary screens again.

Press [] to continue.

If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as follows:

A=00

D=03

G=06

J=09

M=12

P=15

B=01

E=04

H=07

K=10

N=13

 

C=02

F=05

I=08

L=11

O=14

 

 

 

 

 

 

 

02 UNIT CODE

00

Enter the numerical unit code of the X-10 device (00-15). Press [] to continue.

The keypad displays the Start and Stop summary screens again. Press [] to continue.

When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.

If you are defining a zone list, continue to the next section. If not, enter 00 + [] at the next two prompts. You will then be asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter []99 to exit programming completely.

Zone List Programming

After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:

PROMPTEXPLANATION

ENTER Zn LIST ?

00=QUIT00

Enter the zone list number 01-04. Enter 00 to quit.

– 24 –

Image 24
Contents $0&29,67$ N7001PRV5 5/04 Rev aTable of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-40 Programming Form Enable OPEN/CLOSE Report for OPEN/CLOSE Report for Keyswitch54 *57 Alarm Report Codes & ID Digits for Zones 59 *62 Alarm Report Codes & ID Digits for ZonesFields 1*28 1*31 are not applicable for UL installations 2nd Page Programming Fields press *943rd Page Programming Fields press *94 Partition-Specific Fields Partition # Program Fields1st Page Fields 2nd Page FieldsProgramming With #93 Menu Mode Zone Programming SET to CONFIRM? = YESEnter Zone no = Quit Zone Type PERIMETER03Input Type Input S/N AXXX-XXXXInput S/N Series Transmitters Loop Designations Xmit to Confirm Press to SkipExpert Mode Zone Programming Program field 200 Number of PartitionsEnter Zone no SET to CONFIRM?Input S/N XXX-XXXX From TemplateWireless Key Default Templates 5804 5804BDTemplate Loop Function Zone Type Template Loop FunctionZone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP? Zone Descriptors Select Zone Descriptor modeAlpha Descriptors Programming Exit Edit MODE?Select Default Screen mode Select Custom Word ModeAccept the word Select the next wordType the word using one of two methods as follows Follow the same procedure as for custom wordsEnter the custom word number 01-20 you want to create Save the word by pressingCharacter Ascii Chart Alpha Descriptor VocabularyDevice Programming Alpha KeypadRF Expander VIP ModuleAlarm FaultRelay Programming TroubleRelay Output Devices Programming Choices for Start/Stop Zone Types and System OperationsEnter Relay # Relay Action No Response Start Event Not UsedZone List Programming Start Partn ANY PartitionRelay Type Plex ECP Address Module RELAY# House Code Unit CodeRelay Voice Descriptors Custom Word Substitutes for VIP Module Annunciation Custom Word no =QUIT Enter Index #System Layout Worksheets Descriptor Prim Partition # Char max Sub. #Access Codes & User Definitions for Partitions 1 DefaultsZone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for Keypad Panic Zones 95, 96 Zone Definitions for System Zones 70, 88 89, 90, 91Zone Types Input TypesRelay Outputs Worksheets Choices for System Operation arePage Ademco VISTA-40 Summary of Connections GroundEileen Way, Syosset, New York