Honeywell 2-Partitioned Security System Partition-Specific Fields, Partition # Program Fields

Page 9

Partition-Specific Fields

(Duplicate this page for each partition in the installation.) To program these fields,

1.Press *91 to select a partition.

2.Enter a partition-specific field number (ex. *09).

3.Make the required entry.

4.Repeat steps 1-3 for the other partition in the system.

PARTITION #____ PROGRAM FIELDS

1st Page Fields

 

*09

ENTRY DELAY #1

[02]

 

00, 02-15 times 15 seconds.

 

 

Maximum 03 for UL Listed installations.

 

*10

EXIT DELAY #1

[04]

*88 BURG. ALARM COMM. DELAY

[0]

1=16 seconds; 0=no delay. Must be "0" for UL installations.

*90 SEC. SUBS. ACCT #

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15 15]

 

 

 

 

2nd Page Fields

00, 03-15 times 15 seconds.

Maximum 04 for UL Listed installations.

*11

ENTRY DELAY #2

[06]

 

 

 

00, 02-15 times 15 seconds.

 

 

 

 

 

 

 

 

Maximum 03 for UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*12

EXIT DELAY #2

[08]

 

 

 

00, 03-15 times 15 seconds.

 

 

 

 

 

 

 

 

Maximum 04 for UL installations.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*13

ALARM SOUNDER DURATION

[04]

 

 

 

01-15 times 2 minutes.

 

 

 

 

 

 

 

 

Must be minimum 16 minutes for UL installations.

 

*16

CONFIRMATION OF ARMING DING

[0]

 

 

 

1=enable; 0=disable.

 

 

 

 

 

 

 

 

Must be "1" for UL installations.

 

 

 

 

 

 

 

*22

KEYPAD PANIC ENABLES [001]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

995 996

 

999

*23

MULTIPLE ALARMS

[1]

 

 

1=yes; 0=no. Must be 1 for UL installations.

1*43 PERM. KEYPAD BACKLIGHT

[0]

 

1=enable; 0=disable When disabled, display lights when

any key is pressed, and turns off after period of keypad

inactivity.

 

 

1*45

EXIT DELAY SOUNDING

[0]

 

 

 

1=enable; 0=disable. Produces quick beeping during exit

 

 

delay if enabled.

 

 

 

 

1*47

CHIME ON BELL 1

[0]

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

1*52

SEND CANCEL IF ALARM + OFF

[0]

 

 

 

 

 

1=no restriction; 0=within Bell Timeout period only

 

 

 

 

 

 

 

 

1*76

ACCESS CONTROL RELAY FOR PART.[00]

 

Relay will be pulsed for 2 seconds whenever code + [0] is pressed. Enter 00-08; 00=none. Must be "00" for UL installs.

3rd Page Fields

2*18 ENABLE GOTO FOR THIS PARTITION

[0]

1=Allow log-on from other partitions; 0=disable

*29 QUICK ARM

[1]

1=yes; 0=no

2*20 ENABLE J7 TRIGGERS BY PARTITION

[1]

0=disable; 1=enable for

*32

PRIM. SUBS. ACCT #

 

 

 

 

 

 

 

 

Enter 00-09; B-F (11-15)

[15 15 15

15]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*38

PREVENT ZONE XX BYPASS

 

[00]

 

 

 

001-64; 000 if all zones can be bypassed

 

 

 

 

 

 

 

*39

ENABLE OPEN/CLOSE REPORT

 

 

[1]

 

 

 

 

 

 

 

FOR INSTALLER CODE

 

 

 

 

 

 

 

 

 

1=enable; 0=disable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*84

SWINGER SUPPRESSION

 

[03]

 

 

01-15 alarms; Must be "00" (disabled) for UL installations.

*85 ENABLE DIALER REPORTS FOR PANICS & DURESS

1=enable; [0=disable]

995 996 999 Duress

*87 ENTRY WARNING

[1]

1=continuous; 0=3 beeps

SUMMARY OF PROGRAMMING COMMANDS

To enter program mode, enter installer code + [8] + [0] + [0]

To set standard defaults, press *97

To change to next page of program fields, press *94

To return to previous set of fields, press *99

To erase account and phone number field entries, press [*] + field number + [*]

To assign zone descriptors, press #93 + follow menu prompts

To add custom words, press #93 + follow menu prompts

To enter Installer's Message, press #93 + follow menu prompts

To exit program mode, enter *99 OR *98: *99 allows re- access to programming mode by installer code. *98 prevents re-access to programming mode by installer code.

– 9 –

Image 9
Contents N7001PRV5 5/04 Rev a $0&29,67$Table of Contents Recommended Programming Procedure Program Field Index Field GroupField Group VISTA-40 Programming Form OPEN/CLOSE Report for Keyswitch Enable OPEN/CLOSE Report for54 *57 Alarm Report Codes & ID Digits for Zones 59 *62 Alarm Report Codes & ID Digits for Zones2nd Page Programming Fields press *94 Fields 1*28 1*31 are not applicable for UL installations3rd Page Programming Fields press *94 Partition # Program Fields Partition-Specific Fields1st Page Fields 2nd Page FieldsProgramming With #93 Menu Mode SET to CONFIRM? = YES Zone ProgrammingEnter Zone no = Quit Zone Type PERIMETER03Input Type Input S/N AXXX-XXXXInput S/N Xmit to Confirm Press to Skip Series Transmitters Loop DesignationsProgram field 200 Number of Partitions Expert Mode Zone ProgrammingEnter Zone no SET to CONFIRM?From Template Input S/N XXX-XXXX5804BD Wireless Key Default Templates 5804Template Loop Function Zone Type Template Loop FunctionZone Descriptors Select Zone Descriptor mode Zone DESCRIP? Default SCREEN? Custom WORD? Part DESCRIP?Alpha Descriptors Programming Exit Edit MODE?Select Custom Word Mode Select Default Screen modeAccept the word Select the next wordFollow the same procedure as for custom words Type the word using one of two methods as followsEnter the custom word number 01-20 you want to create Save the word by pressingAlpha Descriptor Vocabulary Character Ascii ChartAlpha Keypad Device ProgrammingRF Expander VIP ModuleFault AlarmRelay Programming TroubleChoices for Start/Stop Zone Types and System Operations Relay Output Devices ProgrammingEnter Relay # Relay Action No Response Start Event Not UsedStart Partn ANY Partition Zone List ProgrammingRelay Type Plex ECP Address Module RELAY# House Code Unit CodeRelay Voice Descriptors Custom Word no =QUIT Enter Index # Custom Word Substitutes for VIP Module AnnunciationDescriptor Prim Partition # Char max Sub. # System Layout WorksheetsDefaults Access Codes & User Definitions for Partitions 1Zone Definition for Zones Zone Definition for Zones Zone Definition for Zones Zone Definitions for System Zones 70, 88 89, 90, 91 Zone Definitions for Keypad Panic Zones 95, 96Zone Types Input TypesChoices for System Operation are Relay Outputs WorksheetsPage Ground Ademco VISTA-40 Summary of ConnectionsEileen Way, Syosset, New York