Honeywell HCM-310T Scale Removal, Changing the UV Bulb CONT’D, Cleaning, Turn off and unplug

Page 7

HCM-300T_HCM-310T_OM.qxd 5/22/06 5:56 PM Page 7

CHANGING THE UV BULB (CONTD.)

Step 4

 

 

Step 5

 

 

 

 

 

 

Step 6

Place your replacement UV bulb in the unit by pressing the UV bulb firmly into the opening. Be certain the prongs locate on the back of the bulb are lined up with the receptacle in the UV holder.

Place filter basket and replace the water tank in the humidifier.

NOTE: Discard the old UV bulb cartridge at a household hazardous waste collection site. Bulb and bulb housing are not intended for use with any other product or purpose.

Lamp contains mercury. Manage in accordance with disposal laws.

See www.lamprecycle.org or call 1-800-895-8842.

CLEANING

Cleaning involves two steps, SCALE REMOVAL and DISINFECTING. Be sure to perform these in the proper order to avoid harmful chemical interactions.

NOTE: REMOVE FILTER BEFORE CLEANING.

Failure to remove filter during cleaning will destroy the filter.

SCALE REMOVAL

Step 1

Step 2

Step 3

Step 4

Turn off and unplug

Remove the water tank

Remove filter basket.

your humidifier.

and carefully set aside.

 

 

 

 

 

 

 

 

 

 

 

Step 5

 

 

Step 6

 

 

Step 7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Place basket in sink or

Let stand for 20

With vinegar in the

tub and fill the bottom

minutes.

basket, wipe surface

of the basket with

 

with a soft cloth or

undiluted vinegar.

 

brush.

Remove filter from basket. Failure to do so will destroy the filter.

Step 8

Rinse the filter basket thoroughly with water to remove scale and cleaning solution.

7

7

Image 7
Contents Important Safety Instructions HOW IT Works Your humidifier is made up of these parts Setting UP Your HumidifierHCM-310T / HCM-315T Soak Filter Setting UP Your Humidifier CONT’DPlacement Some flooringModel # Operating Your HumidifierSet Humidity HCM-300T Changing the UV Bulb Changing Your FilterTurn off and unplug CleaningScale Removal Changing the UV Bulb CONT’DConsumer Relations Cleaning CONT’DDisinfecting END-OF-SEASON Care and StorageElectrical Ratings TroubleshootingHoneywell QuietCare Series models are rated at 120V, 60 Hz U.S.A Year Limited WarrantyCanada Placer lhumidificateur hors de la portée des enfants Importantes Instructions DE SécuritéTechnologie de purification d’air Fonctionnement DE L’HUMIDIFICATEURTechnologie de QuietCare Filtre traité antimicrobien ProtecMC’humidificateur est composé des pièces suivantes Installation DE L’HUMIDIFICATEURTrempage Installation DE L’HUMIDIFICATEUR SuiteEmplacement Causés par des déversements d’eauFaible Modèle Réglage de humiditéVitesse du ventilateur HCM-300T ÉlevéeChangement DE L’AMPOULE UV Changement DU FiltreNe pas l’essorer Replacer le réservoirDébrancher Précaution Remplacement DE Ampoule Ultraviolette UV SuiteEnlèvement DE L’INCRUSTATION NettoyageEntretien DE FIN DE Saison ET Entreposage Service À LA ClientèleDésinfection Nettoyage SuiteDépannage Caractéristiques Électriques AssignéesAu Canada Garantie Limitée DE 3 ANSNo use el humidificador al aire libre Instrucciones Importantes DE SeguridadTecnología de QuietCareMC Funcionamiento DEL HumidificadorTecnología de purificación de aire Partes del humidificador Instalación DEL HumidificadorInstalación DEL Humidificador Continuación Interruptor Modelo Control de la humedad yBaja Humidificador y vuelva a prenderloPara Cambiar LA LUZ UV Para Cambiar EL FiltroLimpieza Para Cambiar LA LUZ UV ContinuaciónCuidado AL Final DE LA Temporada Y Almacenamiento DesinfecciónLimpieza Continuación CuidadoCaracterísticas Eléctricas Nominales ProblemasAgujas de un reloj y el aparato se pondrá en marcha En Canada Garantía Limitada DE 3 AñosHCM-300THCM-310TOM.qxd 5/22/06 556 PM HCM-300THCM-310TOM.qxd 5/22/06 556 PM