182 Configurable Zone Type 90

(0-9, #+10=10, #+11=11, #+12=12, #+13=13, #+14=14, #+15=15).

1

2

3

4

5

6

7

8

9

10

Enter the appropriate value for each entry, 1-10, based on the charts provided in the Configurable Zone Type Worksheet section. Each entry is the sum of the values of its selected options

To calculate the value for each entry, add the values of the selected options in each of the entry’s columns shown in the respective chart (one option per column). For example, to program entry 2 for “alarm response to short,” “auto restore on,” but not a “vent zone,” enter 5 (“1” for alarm short + “4” for auto restore-yes + “0” for vent zone-no).

UL: Do not configure zones as a fire alarm or UL burglar alarm zone.

183 Zone Type 90 Report Codes

90 ALARM ID: XXX TROUBLE ID: XXX

Press [] when done to continue.

Enter the desired 3-digit Contact ID® report codes for alarms and troubles occurring on zones assigned to this zone type. Enter the codes sequentially (all 6 digits). When entering digits, [#] moves cursor back, [] moves forward.

NOTE: Zone alarm report codes and trouble report code (60) and relevant restore codes must be enabled in order to report configurable zone type codes.

Important Notice on Report Codes: To avoid confusion at the central station, it is recommended that existing Contact ID® codes be used with configurable zone types whenever possible. Check with the central station for a complete list of Contact ID® report codes. If none of the codes are suitable, choose a code in the reserved range of 750-789 and make sure to define the code with your central station.

 

184

Configurable Zone Type 91

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(0-9, #+10=10, #+11=11, #+12=12,

1

2

3

4

5

6

7

8

9

10

 

 

 

 

#+13=13, #+14=14, #+15=15)

 

 

 

 

See 182 for entries.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UL: Do not configure zones as a fire alarm or UL burglar alarm zone.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Zone Type 91 Report Codes

 

See 183 for entries.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

185

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

91 ALARM ID: XXX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLE ID: XXX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

189 AUI Device Enables

(for Touch Screen Style Keypads) FA168CPS: Enter each touch screen keypad’s home partition

0 = disable

1 = partition 1

2 = partition 2

3 = partition 3 (common)

FA148CP: 0 = disable 1 = enable

[1, 1, 0, 0]

AUI 1

AUI 2 AUI 3 AUI 4

System supports touch screen style keypads (e.g., Symphony Advanced User Interface, and 6270 Touch Screen Keypad; FA168CPS = up to 4; FA148CP = up to 2).

NOTE: Use of touch screen style keypads does not affect the number of standard keypads supported.

AUI Compatibility Note: To ensure proper AUI device operation, use

AUI devices with the following rev levels: FA700KP series use version 1.0.9 or higher; 8132/8142 (Symphony) series use version 1.1.175 or higher.

Touch Screen (AUI) device 1: Must set device address to 1

Touch Screen (AUI) device 2: Must set device address to 2 Touch Screen (AUI) device 3: Must set device address to 5 Touch Screen (AUI) device 4: Must set device address to 6

– 15 –

Image 15
Contents K5305-5PRV5 11/08 Rev. B FA168CPS / FA168CPSSIA FA148CP / FA148CPSIATable of Contents RF transmitters Programming Mode CommandsInstaller code + # + 03 enable AVS operation Special MessagesData Field Programming Form ∗34 ∗31∗32 ∗33∗45 ∗46 ∗39∗40 ∗41 ∗42∗55 ∗50∗53 ∗54∗62 ∗59∗60 ∗61∗69 ∗66∗67 ∗68∗85 ∗77∗78 ∗84∗88 ∗90∗91 ∗95 ∗93∗167 ∗163∗164 ∗166∗171 ∗177∗181 ∗185 ∗184∗194 ∗191∗192 ∗193Field *182 Configurable Zone Types WorksheetsEntries for Fields *182 and *184 Entry Zone Type∗56 Zone Programming Menu Mode Input Device type Hardwire TypeReport Code RC Response Time RT∗58 Expert Zone Program Mode Wireless KEY Programming Templates Not Confirmed Wireless Key Transmitter5804BD 2-Way Wireless Key Transmitter ConfirmFA168CPS ∗57 Function KEY Programming Menu ModeFunction Key Partition NumberOutput Normally Low Programming Output DevicesOutput Identification Device Output Number∗80 Output Function Menu Mode Zone Type Menu Mode Output Function NoActivated By Zone ListOutput Number ∗81 Zone List Menu ModeMenu Mode Zone List Number Output Action∗82 Alpha Descriptor Menu Mode ZN 01 Back Door Descriptor ExampleZN 01 Back D OOR Example Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Repeat Option Setting the REAL-TIME ClockQuick Program Command Results Pre-Programmed #03 Command #04 CommandProgramming ∗29 IP/GSM Program ModeEnable IP/GSM? Diagnostics SelectZone Type Definitions SIA Quick Reference Guide UL NoticesReserved Zones Worksheet for ∗56 Zone ProgrammingOption Function Comments Worksheet for ∗57 Function KEY ProgrammingWorksheet for ∗81 Zone List Programming List No Used For… Contains These Zones…FA168CPS Worksheet for ∗80 Output Function ProgrammingDays Reports as†† Enabled By…Worksheet for Schedules Table of Device Addresses5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN Series Transmitter Input Loop Identification

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.