First Alert FA148CPSSIA manual ∗39, ∗40, ∗41 ∗42, ∗45 ∗46, ∗48

Page 6

39

 

 

Power Up In Previous State

 

 

 

0 = no, always power up disarmed;

 

 

 

1 = yes, power up in previous state

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA-Compliant Controls:

Feature

 

 

 

 

 

always enabled; field does

not exist.

 

 

 

 

 

 

 

 

DIALER PROGRAMMING (40 – 42)

When the system powers up armed, an alarm will occur 1 minute after arming if a zone is faulted. Note that if the previous state was armed Away or Stay, the system ignores sensor changes for 1 minute, which allows sensors such as PIRs to stabilize.

UL: must be 1

SIA Guidelines: must be 1

40

 

 

PABX Access Code or Call

 

 

 

Waiting Disable

 

 

 

Enter up to 6 digits.

 

 

 

To clear entries, press 40.

 

 

 

If call waiting is used, enter call waiting

 

 

 

disable digits “(#+11) 70” plus “# +

 

 

 

13” (pause).

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA-Compliant Controls:

If call

 

 

 

 

 

waiting is used, enter call

waiting

 

 

 

 

 

disable digits as described above,

 

 

 

 

 

and also set Call Waiting Disable

 

 

 

 

 

option in field *91.

 

Call Waiting: If the subscriber’s phone service has “call waiting” (and is not using PABX), enter “*70” (“# + 11”) plus “# + 13” (pause) as the PABX entry to disable “call waiting” during control panel calls. If the subscriber does not have “call waiting” and is not using PABX, make no entry in this field.

NOTES:

1.The call waiting disable feature cannot be used on a PABX line.

2.Using Call Waiting Disable on a non-call waiting line will prevent successful communication to the central station.

41

42

Primary Phone No. Secondary Phone No.

Do not fill unused spaces. 0–9

#+11 for '' #+12 for '#'

#+13 for a 2-second pause

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Enter up to 20 digits. To clear entries, press 41or 42respectively. Enter the respective phone numbers. If fewer than the maximum digits entered, exit the field by pressing []. The next data field number is displayed.

43 44

45

46

Partition 1 Primary Acct. No.

Part. 1 Secondary Acct. No.

Partition 2 Primary Acct. No.

Partition 2 Secondary Acct. No.

Enter 4 or 10 digits, as chosen in *48 Report Format. Enter digits 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E; #+15 for F.

/

 

 

[FFFFFFFFFF]

 

 

 

 

 

 

 

 

 

 

 

 

/

 

 

[FFFFFFFFFF]

/

 

[FFFFFFFFFF]

/

 

[FFFFFFFFFF]

Enter [] as the fourth digit if a 3-digit account number (for 3+1 dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account number for 0000-0999. E.g., For Acct. B234, enter: #+11 + 2 + 3 + 4 To clear entries in a given field, press *43*, *44*, *45*, or *46* based on the field being programmed

47 Phone System Select

If Cent. Sta. is not on a WATS line: 0=Pulse Dial; 1=Tone Dial

If Cent. Sta. is on a WATS line: 2 = Pulse Dial ; 3 = Tone Dial

[1]

Select the type of phone service for the installation.

 

48

Report F ormat

 

[77]

 

 

0

= 3+1, 4+1 ADEMCO L/S STANDARD

primary

secondary

 

 

1

= 3+1, 4+1 RADIONICS STANDARD;

 

 

Select the format for primary/secondary phone numbers

 

 

2

= 4+2 ADEMCO L/S STAND.

 

 

 

 

 

 

3

= 4+2 RADIONICS STANDARD

 

 

 

 

5

= 10-digit ADEMCO CONTACT ID®

 

 

 

 

 

REPORTING

 

 

 

 

6

= 4+2 ADEMCO EXPRESS

 

 

 

 

7

= 4-digit ADEMCO CONTACT ID®

 

 

 

 

 

REPORTING

 

 

 

 

8

= 3+1, 4+1 ADEMCO L/S EXP.;

 

 

 

 

9

= 3+1, 4+1 RADIONICS EXP

 

 

49 Split/Dual Reporting

0 = Standard/backup reporting only (all to primary)

1-5 = see table at right

[0]

Backup Reporting: All reports are sent only to the primary number unless unsuccessful after 8 attempts. If unsuccessful, the system will make up to 8 attempts to send all reports to the secondary number. If still unsuccessful after the 16 attempts, the system displays the “COMM. FAILURE” message (FC for fixed-word displays).

Primary Phone No.

2nd Phone No.

 

1

= Alarms, Restore, Cancel

Others

2

= All except Open/Close, Test

Open/Close, Test

3

= Alarms, Restore, Cancel

All

4

= All except Open/Close, Test

All

5

= All

 

 

– 6 –

Image 6
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Special Messages Programming Mode CommandsInstaller code + # + 03 enable AVS operation RF transmittersData Field Programming Form ∗33 ∗31∗32 ∗34∗41 ∗42 ∗39∗40 ∗45 ∗46∗54 ∗50∗53 ∗55∗61 ∗59∗60 ∗62∗68 ∗66∗67 ∗69∗84 ∗77∗78 ∗85∗88 ∗90∗91 ∗93 ∗95∗166 ∗163∗164 ∗167∗171 ∗177∗181 ∗184 ∗185∗193 ∗191∗192 ∗194Entry Zone Type Configurable Zone Types WorksheetsEntries for Fields *182 and *184 Field *182∗56 Zone Programming Menu Mode Response Time RT Hardwire TypeReport Code RC Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Confirm Wireless Key Transmitter5804BD 2-Way Wireless Key Transmitter Not ConfirmedPartition Number ∗57 Function KEY Programming Menu ModeFunction Key FA168CPSDevice Output Number Programming Output DevicesOutput Identification Output Normally Low∗80 Output Function Menu Mode Zone List Menu Mode Output Function NoActivated By Zone TypeOutput Action ∗81 Zone List Menu ModeMenu Mode Zone List Number Output Number∗82 Alpha Descriptor Menu Mode Example Back Door Descriptor ExampleZN 01 Back D OOR ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Pre-Programmed #03 Command #04 Command Setting the REAL-TIME ClockQuick Program Command Results Repeat OptionDiagnostics Select ∗29 IP/GSM Program ModeEnable IP/GSM? ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesList No Used For… Contains These Zones… Worksheet for ∗57 Function KEY ProgrammingWorksheet for ∗81 Zone List Programming Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSTable of Device Addresses Reports as†† Enabled By…Worksheet for Schedules DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.