Single Alarm Sounding Per Zone

 

0

= unlimited sounding

 

1

= one alarm sounding per zone

SIA-Compliant Controls: If “0” selected, “alarm sounding per zone” will be the same as the “number of reports in armed period” set in field *93 (1 if one report, 2 if 2 reports, unlimited for zones in zone list 7).

[0]

If enabled, limits alarm sounding on the bell output to once per zone per armed period.

32

Fire Alarm Sounder Timeout

 

0

= sound stops at timeout selected in

 

 

field 33

 

1

= no timeout; sounds until manually

 

 

turned off

[0]

This control complies with NFPA requirements for temporal pulse sounding of fire notification appliances. Temporal pulse sounding for a fire alarm consists of the following: 3 pulses – pause – 3 pulses – pause – 3

pulses.

UL: must be 1 for fire installations

33

Alarm Sounder (Bell) Timeout

 

0

= none

3 =12 min

 

1

= 4 min

4 = 16 min

 

2

= 8 min

 

[1]

This field determines whether the external sounder will shut off after time allotted, or continue until manually turned off.

UL: For residential fire alarm installation, must be set for a minimum of 4 min (option 1); for UL Commercial Burglary installations, must be minimum 16 min (option 4)

34

Exit Delay

 

00

- 96 = 0 - 96 secs

 

97

= 120 secs

SIA-Compliant Controls:

45 - 96 = 45 - 96 secs; 97 = 120 secs NOTE: Entries less than 45 will result in a 45-second delay.

[60,60]

Part. 1

Part. 2

 

The system waits the time entered before arming entry/exit zones. If the entry/exit door is left open after this time expires, an alarm will occur. Common zones use same delay as partition 1.

SIA Guidelines: minimum exit delay is 45 seconds Common zones use part. 1 delay.

UL installations: For UL Commercial Burglar Alarm and UL Residential Burglar Alarm installations with line security, total exit time must not exceed 60 seconds.

 

35

 

Entry Delay #1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[30,30]

 

 

 

 

00 - 96 = 0 - 96 seconds

 

Part. 1

Part. 2

 

 

 

 

 

97 = 120 secs

 

 

 

 

 

 

 

Upon entering, the system must be disarmed before the time entered

 

 

 

 

98 = 180 secs

 

 

 

 

 

 

expires, otherwise it sounds an alarm.

 

 

 

 

99 = 240 secs

 

 

 

 

 

 

Common zones use same delay as part 1.

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA-Compliant Controls:

 

 

SIA Guidelines: minimum entry delay is 30 seconds

 

 

 

 

 

30-96 = 30 - 96 secs; 97 = 120 secs;

 

 

For UL Residential Burglary Alarm installations, must be set for a maximum of

 

 

 

 

 

 

 

30 seconds; entry delay plus dial delay should not exceed 1 min. For UL

 

 

 

 

 

98 = 180 secs; 99 = 240 secs

 

 

 

 

 

 

 

 

 

Commercial Burglar Alarm, total entry delay may not exceed 45 seconds.

 

 

 

 

 

NOTE: Entries less than 30 will result

 

 

 

 

 

 

 

 

 

Upon entering, the system must be disarmed before the time entered expires,

 

 

 

 

 

in a 30-second delay.

 

 

 

 

 

 

 

 

 

otherwise it sounds an alarm.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Entry Delay #2

 

 

 

 

 

 

 

36

 

 

 

 

 

 

 

 

 

 

 

[30,30]

 

 

 

 

See *35 Entry Delay 1 for entries.

 

 

 

 

 

 

 

 

 

 

 

 

Part. 1

Part. 2

 

 

 

 

 

 

 

 

 

 

 

37

 

 

Audible Exit Warning

 

 

 

0 = no; 1 = yes

 

 

 

 

 

 

 

 

 

 

 

SIA-Compliant Controls:

Feature

 

 

 

 

 

always enabled; field does

not exist.

 

 

 

 

 

 

 

 

[1,1]

Part. 1

Part. 2

Warning sound consists of slow continuous beeps until the last 10 seconds, and then it changes to fast beeps. Sound ends when exit time expires.

SIA Guidelines: must be enabled

38

Confirmation Of Arming Ding

 

0

= no

 

1

= yes (wired keypads and RF)

 

2

= yes, RF only (except 5827,

 

 

5827BD)

[0,0]

Part. 1

Part. 2

Confirmation of arming is 1/2-sec external sounder “ding.”

If 1 selected, ding occurs when closing report is sent if open/close reporting is enabled, or at the end of Exit Delay. If 2 selected, ding occurs upon reception of the wireless arming command.

UL: must be 1 for UL Commercial Burglar Alarm inst.

– 5 –

Image 5
Contents K5305-5PRV5 11/08 Rev. B FA168CPS / FA168CPSSIA FA148CP / FA148CPSIATable of Contents Installer code + # + 03 enable AVS operation Programming Mode CommandsSpecial Messages RF transmittersData Field Programming Form ∗32 ∗31∗33 ∗34∗40 ∗39∗41 ∗42 ∗45 ∗46∗53 ∗50∗54 ∗55∗60 ∗59∗61 ∗62∗67 ∗66∗68 ∗69∗78 ∗77∗84 ∗85∗91 ∗88∗90 ∗95 ∗93∗164 ∗163∗166 ∗167∗181 ∗171∗177 ∗185 ∗184∗192 ∗191∗193 ∗194Entries for Fields *182 and *184 Configurable Zone Types WorksheetsEntry Zone Type Field *182∗56 Zone Programming Menu Mode Report Code RC Hardwire TypeResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates 5804BD 2-Way Wireless Key Transmitter Wireless Key TransmitterConfirm Not ConfirmedFunction Key ∗57 Function KEY Programming Menu ModePartition Number FA168CPSOutput Identification Programming Output DevicesDevice Output Number Output Normally Low∗80 Output Function Menu Mode Activated By Menu Mode Output Function NoZone List Zone TypeMenu Mode Zone List Number ∗81 Zone List Menu ModeOutput Action Output Number∗82 Alpha Descriptor Menu Mode ZN 01 Back D OOR Descriptor ExampleExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Quick Program Command Results Setting the REAL-TIME ClockPre-Programmed #03 Command #04 Command Repeat OptionEnable IP/GSM? ∗29 IP/GSM Program ModeDiagnostics Select ProgrammingZone Type Definitions SIA Quick Reference Guide UL NoticesReserved Zones Worksheet for ∗56 Zone ProgrammingWorksheet for ∗81 Zone List Programming Worksheet for ∗57 Function KEY ProgrammingList No Used For… Contains These Zones… Option Function CommentsFA168CPS Worksheet for ∗80 Output Function ProgrammingWorksheet for Schedules Reports as†† Enabled By…Table of Device Addresses Days5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN Series Transmitter Input Loop Identification

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.