80 Menu Mode

 

 

 

 

 

 

Output Function No.

Enter the output function number to be defined (or 00 to exit)

 

Output Funct. #

 

(FA168CPS: 01-48

 

 

 

(00 = Quit)

 

01

 

 

 

 

(FA148CP: 01-24)

 

 

 

 

 

 

 

 

[] to continue; 00 to quit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary Screen

This screen displays a summary of the current output

 

01

A

E

P

Trig

 

[] to continue

programming (for this example, Zone List has been selected-this

 

?00

0

0

ZL=00

 

 

is the default screen).

 

 

 

 

 

 

 

A = Output Action; E = Triggering event; P = Partition;

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Trig = Trigger type

 

 

 

 

 

 

 

NOTE: A question mark in the summary screen indicates that the

 

 

 

 

 

 

 

device number shown has not been mapped. Use *79 Menu

 

 

 

 

 

 

 

mode to map the device.

 

 

 

 

 

 

Activated By

Select where the initiating event for this output definition is to

 

01 Activated By:

 

0 = delete

occur as follows:

 

Zone List

 

 

 

 

 

1 = zone list (go to “A”)

If you enter “0,” the following prompt appears:

 

 

 

 

 

 

2 = zone type (go to “B”)

Delete?

 

 

 

 

 

 

 

3 = zone number (go to “C”)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

[] to continue

0 = NO, 1 = YES

 

 

 

 

 

 

 

 

 

 

Press 1 to delete this output definition. The system deletes the output function and any previous programming.

A

01 Zn List

1

Zone List

01-08 = zone list [] to continue

(prompt appears if zone list was selected)

Enter the desired zone list number associated with this output number. At the ENTER EVENT prompt, enter the zone list event that will activate this output

NOTE: Do not use pager zone lists 09-12 in output definitions.

Enter Event

Alarm 1

0 = restore; 1 = alarm;

2 = fault; 3= trouble

 

 

 

 

NOTE: For alarm, fault, and trouble, an event on ANY zone in the

 

 

 

 

list activates the output, but ALL zones in the list must be

 

 

 

 

restored before the output is restored.

 

 

 

 

 

 

Press [] to continue and skip to the “Output Action” prompt.

 

B

 

Zone Type

(prompt appears if zone type was selected)

 

 

 

 

See list at right for available

Enter the desired zone type associated with this output number.

 

01 Enter Zn type

 

 

 

zone types.

At the PARTITION prompt, enter the partition in which this zone

 

Perimeter

03

 

 

type will occur.

 

 

 

 

 

 

 

 

 

 

CHOICES FOR ZONE TYPES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00

= Not Used

05

= Day/Night

12

= Monitor Zone

 

 

 

 

01

= Ent/Exit #1

06

= 24 Hr Silent

14

= Carbon Monoxide††

 

 

 

 

02

= Ent/Exit #2

07

= 24 Hr Audible

16

= Fire w/verification

 

 

 

 

03

= Perimeter

08

= 24 Hr Aux

23

= No Alarm Response

 

 

 

 

04

= Interior Follower

09

= Fire

24

= Silent Burglary

 

 

 

 

 

 

10

= Interior w/Delay

77

= Keyswitch Zone

 

 

 

 

 

 

 

 

 

81

= AAV Monitor Zone

 

 

 

 

 

 

 

 

 

90-91 = Configurable

 

 

 

 

CHOICES FOR SYSTEM OPERATION:

 

 

 

 

 

20

= Arming–Stay

36

= **At Bell Timeout***

58

= Duress

 

 

 

 

21 = Arming–Away

38 = Chime

 

60

= AAV

 

 

 

 

22

= Disarming

39

= Any Fire Alarm

 

61

= AVS/GSMV session begin§

 

 

 

 

31

= End of Exit Time

40

= Bypassing

 

62

= AVS/GSMV session end §

 

 

 

 

32

= Start of Entry Time

41

= **AC Power Failure

66

= Function Key†

 

 

 

 

33

= Any Burglary Alarm

42

= **System Battery Low 67

= Bell Fail

 

 

 

 

 

 

43

= Comm. Failure

 

68

= Telco Line Cut

 

 

 

 

 

 

52

= Kissoff

 

78

= Keyswitch Red LED

 

 

 

 

 

 

54

= Fire Zone Reset

 

79

= Keyswitch Green LED

**Use 0 (Any) for Partition No. (P) entry.

***Or at Disarming, whichever occurs earlier.

† Use *57 Menu Mode to assign the function key (function “07”).

††when used with an output function, the carbon monoxide zone type activates upon CO alarms only. Does not activate for trouble conditions. § automatically set when appropriate AVS Quick Command performed.

Note: In normal operation mode:

Code + # + 7 + NN Key Entry starts Device NN.

Code + # + 8 + NN Key Entry stops Device NN.

Enter the partition in which this zone type will occur.

 

01 Partition

0

= any partition; 1 = partition 1;

 

 

 

 

 

 

 

 

 

 

Any partition 0

2

= partition 2; 3 = common

Press [] to continue and skip to the “Output Action” prompt.

– 26 –

Image 26
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Special Messages Programming Mode CommandsInstaller code + # + 03 enable AVS operation RF transmittersData Field Programming Form ∗33 ∗31∗32 ∗34∗41 ∗42 ∗39∗40 ∗45 ∗46∗54 ∗50∗53 ∗55∗61 ∗59∗60 ∗62∗68 ∗66∗67 ∗69∗84 ∗77∗78 ∗85∗91 ∗88∗90 ∗93 ∗95∗166 ∗163∗164 ∗167∗181 ∗171∗177 ∗184 ∗185∗193 ∗191∗192 ∗194Entry Zone Type Configurable Zone Types WorksheetsEntries for Fields *182 and *184 Field *182∗56 Zone Programming Menu Mode Response Time RT Hardwire TypeReport Code RC Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Confirm Wireless Key Transmitter5804BD 2-Way Wireless Key Transmitter Not ConfirmedPartition Number ∗57 Function KEY Programming Menu ModeFunction Key FA168CPSDevice Output Number Programming Output DevicesOutput Identification Output Normally Low∗80 Output Function Menu Mode Zone List Menu Mode Output Function NoActivated By Zone TypeOutput Action ∗81 Zone List Menu ModeMenu Mode Zone List Number Output Number∗82 Alpha Descriptor Menu Mode Example Back Door Descriptor ExampleZN 01 Back D OOR ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Pre-Programmed #03 Command #04 Command Setting the REAL-TIME ClockQuick Program Command Results Repeat OptionDiagnostics Select ∗29 IP/GSM Program ModeEnable IP/GSM? ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesList No Used For… Contains These Zones… Worksheet for ∗57 Function KEY ProgrammingWorksheet for ∗81 Zone List Programming Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSTable of Device Addresses Reports as†† Enabled By…Worksheet for Schedules DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.