First Alert FA148CPSSIA ∗57 Function KEY Programming Menu Mode, Function Key, Partition Number

Page 23
For the Function key selected, the functions are predefined as follows:
If A selected = Zone 95 (emergency key, same as [1] [] pair) If B selected = Zone 99 (emergency key, same as [] [#] pair) If C selected = Zone 96 (emergency key, same as [3] [#] pair) If D selected = Single-button paging
Single-button paging (sends a 999-9999 message to pager) Display time
Arm AWAY (reports as User 00 if closing reports are enabled) Arm STAY (reports as User 00 if closing reports are enabled) Arm NIGHT-STAY (reports as User 00 if closing reports enabled)
Step Arming (arms STAY, then NIGHT-STAY†††, then AWAY) Output Device Command (for device programmed as system operation type 66–function key in *80 Menu Mode) Communication Test (sends Contact ID code 601)
Macro Key 1 (define macro by user code + [#] [6] [6] command) Macro Key 2 (define macro by user code + [#] [6] [6] command)

57 FUNCTION KEY PROGRAMMING MENU MODE

(press 57 while in Data Programming mode).

The system provides the ability to program each of the four keypad function keys to perform one of 12 system operations. The end user can then activate the function by simply pressing and holding the programmed key for 2 seconds. Typical functions (listed below) include single-button arming, turning lights on/off, or single-button paging.

To assign emergency key functions (function key option “00”), first program the respective emergency zone number (95 for “A” key, 96 for “C” key, 99 for “B” key) with the desired zone type using 56 (or 58) Zone Programming mode, then use 57 Function Key menu mode to assign the desired key.

To use a function key to activate a relay action (57 Menu mode key function 07), use 79 Menu mode to map the output, and use 80 Menu mode to define the output’s action; select system operation type “66.”

To use a function key for a user macro, use 57 menu mode to activate the desired key, then define the actual macro functions using the user code + [#] + [6] [6] command.

Press Key to Pgm

 

0 = Quit

0

Function Key

Press the desired function key, A-D.

[] to continue

0 = Exit this mode

Press the desired function key (A-D) you want to program. NOTE: A key programmed as a function key is no longer available to be used as an end-user macro key or panic key.

A

1

OFF

2

AWAY

3

STAY

 

B

4

MAX

5

TEST

6

BYPASS

-00-001-V0

C

7

INSTANT

8

CODE

9

CHECK

D

* READY

0

 

#

 

keypad keys

Partition

1

Partition Number

Enter the partition in which the function key is active.

(FA168CPS)

 

1

= partition 1

 

2

= partition 2

 

3

= common partition

 

[] to continue

Key "A" Func

 

Zone 95

00

Define Key Function

00-12 = see list at right

[] to continue; returns to key number prompt with the next function key letter displayed

Enter the desired function for this key, 00 to 12, from the options listed. (00 selected for example display shown at left). Press [] to returns to key number prompt with the next function key letter displayed.

00=

01 =

02 =

03 =

04 =

05 =

06 =

07 =

08 =

09 =

10 =

11†† = Macro Key 3 (define macro by user code + [#] [6] [6] command) 12†† = Macro Key 4 (define macro by user code + [#] [6] [6] command)

† System defaults to these function key settings.

††Macros 11-12 apply to FA168CPS only.

††† If Night-Stay zones are listed in zone list 5

– 23 –

Image 23
Contents K5305-5PRV5 11/08 Rev. B FA168CPS / FA168CPSSIA FA148CP / FA148CPSIATable of Contents RF transmitters Programming Mode CommandsInstaller code + # + 03 enable AVS operation Special MessagesData Field Programming Form ∗34 ∗31∗32 ∗33∗45 ∗46 ∗39∗40 ∗41 ∗42∗55 ∗50∗53 ∗54∗62 ∗59∗60 ∗61∗69 ∗66∗67 ∗68∗85 ∗77∗78 ∗84∗91 ∗88∗90 ∗95 ∗93∗167 ∗163∗164 ∗166∗181 ∗171∗177 ∗185 ∗184∗194 ∗191∗192 ∗193Field *182 Configurable Zone Types WorksheetsEntries for Fields *182 and *184 Entry Zone Type∗56 Zone Programming Menu Mode Input Device type Hardwire TypeReport Code RC Response Time RT∗58 Expert Zone Program Mode Wireless KEY Programming Templates Not Confirmed Wireless Key Transmitter5804BD 2-Way Wireless Key Transmitter ConfirmFA168CPS ∗57 Function KEY Programming Menu ModeFunction Key Partition NumberOutput Normally Low Programming Output DevicesOutput Identification Device Output Number∗80 Output Function Menu Mode Zone Type Menu Mode Output Function NoActivated By Zone ListOutput Number ∗81 Zone List Menu ModeMenu Mode Zone List Number Output Action∗82 Alpha Descriptor Menu Mode ZN 01 Back Door Descriptor ExampleZN 01 Back D OOR Example Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Repeat Option Setting the REAL-TIME ClockQuick Program Command Results Pre-Programmed #03 Command #04 CommandProgramming ∗29 IP/GSM Program ModeEnable IP/GSM? Diagnostics SelectZone Type Definitions SIA Quick Reference Guide UL NoticesReserved Zones Worksheet for ∗56 Zone ProgrammingOption Function Comments Worksheet for ∗57 Function KEY ProgrammingWorksheet for ∗81 Zone List Programming List No Used For… Contains These Zones…FA168CPS Worksheet for ∗80 Output Function ProgrammingDays Reports as†† Enabled By…Worksheet for Schedules Table of Device Addresses5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN Series Transmitter Input Loop Identification

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.