First Alert FA148CPSSIA Programming Output Devices, Output Identification, Device Output Number

Page 24

OUTPUT DEVICE PROGRAMMING GENERAL INFORMATION (*79/*80 Menu Mode)

Output Devices: The FA168CPS system supports up to 16 relays and/or Powerline Carrier devices (X-10 devices) plus 2 built-in trigger outputs in any combination. These 18 “outputs” are assigned to system-wide output numbers (01-18). Use *79 Menu Mode to assign output numbers and map them to device addresses.

The FA148CP supports 8 relays and 2 built-in trigger outputs (total 10 outputs).

Output Functions: The system also provides installer-defined output functions, which can be assigned to any of the physical outputs. Therefore, the action of any one of the outputs can be based on as many of these defined functions as desired. This lets a single relay or X-10 device perform many functions.

The control supports: FA168CPS = up to 48 defined functions; FA148CP = up to 24 functions Use *80 Menu Mode to define output functions.

WARNING: Relays and output devices are not recommended for life safety applications.

NOTE: When navigating the *79 and *80 menus: The [] key is used to accept an entry and advance to the next prompt. The [#] key is used to revert back to the last question to check or change an entry. Press [] to go forward again.

Programming Output Devices

1.Use *79 Menu Mode to assign module and output numbers and map them to device addresses. NOTE: You must map output devices using *79 Menu Mode before you can use *80 menu Mode.

2.Use *80 Menu Mode to create output definitions, which control the output devices, if desired.

3.Use *81 Zone List Menu mode to define zone lists for use with output devices if the device action is based on more than one zone.

To program a device for manual activation (user code + [#] [7] / [#] [8] + 2-digit device number) or for scheduled automatic activation, simply map the device using *79 Menu mode.

To program a device to automatically activate upon a system event (or function key), use *79 Menu mode to map the device, then use *80 Menu mode to define the automated device action.

79 RELAY/POWERLINE CARRRIER DEVICE (X-10) PROGRAMMING MENU MODE

(press 79 while in Programming mode) The *79 Device Mapping Worksheet is on page Error! Bookmark not defined.. Use this menu to assign Relay Module device addresses and specific relay numbers, and Powerline Carrier unit numbers. The system is based on predefined module addresses for 4204 and 4229 modules. Refer to the table shown at the “Module Address” prompt on the next page and set the modules’ addresses (via module DIP switches) accordingly.

The following table shows how these outputs are identified.

Output Identification

 

This output…

is identified by…

 

Relays

the Relay Module’s device address and the relay position on that module (i.e. the physical relay

 

 

number, 1-4, on that module).

 

X-10 Device

a house ID (entered in data field *27) and the unit number of the device.

 

Built-in Outputs

the output number assigned, 17 for Trigger 1 and/or 18 for Trigger 2.

 

 

 

 

 

 

Device Output Number

This is the logical (or reference) relay number as used in the

 

ENTER OUTPUT NO.

 

FA168CPS:

system. Relays and X-10 devices are numbered 01-16; the on-

 

00 = QUIT

xx

 

01-16 = relays/X-10

board triggers are numbered 17 and 18 and can be programmed

 

 

 

 

 

 

17, 18 = on-board triggers

for inverted output, if required.

 

 

 

FA148CP:

 

 

 

 

01-08 = relays/X-10

 

 

 

 

17, 18 = on-board triggers

 

 

 

 

[] to continue

 

 

 

 

00 to quit

 

 

 

 

Output Normally Low

(prompt appears only for Triggers 17 and 18)

 

17 OUT NORM LOW

 

0 = no (standard default)

Selecting 0 (no) sets the output level normally high (default

 

0 = NO 1 = YES

0

 

1 = yes

setting).

 

 

 

 

 

 

[] to continue

Selecting 1 (yes) sets the output normally low.

Output Trigger 17 can be used for resetting 4-wire smoke detectors by connecting it to the negative power terminal of the smoke detector, selecting 1 at this prompt, and setting as zone type 54, fire zone reset, in *80 Menu mode.

After entry, display returns to Output Number prompt. Use *80 Menu mode to program the function of the trigger.

– 24 –

Image 24
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Programming Mode Commands Installer code + # + 03 enable AVS operationSpecial Messages RF transmittersData Field Programming Form ∗31 ∗32∗33 ∗34∗39 ∗40∗41 ∗42 ∗45 ∗46∗50 ∗53∗54 ∗55∗59 ∗60∗61 ∗62∗66 ∗67∗68 ∗69∗77 ∗78∗84 ∗85∗88 ∗90∗91 ∗93 ∗95∗163 ∗164∗166 ∗167∗171 ∗177∗181 ∗184 ∗185∗191 ∗192∗193 ∗194Configurable Zone Types Worksheets Entries for Fields *182 and *184Entry Zone Type Field *182∗56 Zone Programming Menu Mode Hardwire Type Report Code RCResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Wireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterConfirm Not Confirmed∗57 Function KEY Programming Menu Mode Function KeyPartition Number FA168CPSProgramming Output Devices Output IdentificationDevice Output Number Output Normally Low∗80 Output Function Menu Mode Menu Mode Output Function No Activated ByZone List Zone Type∗81 Zone List Menu Mode Menu Mode Zone List NumberOutput Action Output Number∗82 Alpha Descriptor Menu Mode Descriptor Example ZN 01 Back D OORExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Setting the REAL-TIME Clock Quick Program Command ResultsPre-Programmed #03 Command #04 Command Repeat Option∗29 IP/GSM Program Mode Enable IP/GSM?Diagnostics Select ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesWorksheet for ∗57 Function KEY Programming Worksheet for ∗81 Zone List ProgrammingList No Used For… Contains These Zones… Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSReports as†† Enabled By… Worksheet for SchedulesTable of Device Addresses DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.