First Alert FA148CPSSIA manual Worksheet for ∗56 Zone Programming, Reserved Zones

Page 36

WORKSHEET FOR 56 ZONE PROGRAMMING

(FA148CP supports up to 32 zones: 1-6, 9-34, 49-56) [default shown in brackets]

Zone

Zn Type

Part.

Report

Hardwire

 

Rsp. Time

Location

 

 

 

 

Type

 

 

 

1

[09]

[1]

 

[EOL]

 

[1]

 

2

[01]

[1]

 

[EOL]

 

[1]

 

3

[03]

[1]

 

[EOL]

 

[1]

 

4

[03]

[1]

 

[EOL]

 

[1]

 

5

[03]

[1]

 

[EOL]

 

[1]

 

6

[03]

[1]

 

[EOL]

 

[1]

 

7

[03]

[1]

 

[EOL]

[1]

 

8

[03]

[1]

 

[EOL]

[1]

 

NOTES:

Zone Type: see chart in 56 Zone Programming Menu mode section.

Report Code: enabled if any digit entered as 1st digit;

Hardwire Type (zns 2-8):

0

= EOL

3 = ZD

1

= NC

4 = DB

2

= NO

 

Input Type:

2 = AW (zones 9-48)

3 = RF (zones 9-48)

4 = UR (zones 9-48)

5 = BR (zones 49-64) NOTE: Zones 9-16 not available if zone doubling enabled.

Response Time: 0 = 10msec

1 = 350msec

2 = 700msec

3 = 1.2 sec

Reserved Zones

91 = addressable device report enable/disable default zone type = [05].

92 = Duress report enable/disable

Zone

Zn Type

Part.

Report

Input Type

Loop

Serial No.

Location

9

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

33

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

36

 

 

 

 

 

 

 

37

 

 

 

 

 

 

 

38

 

 

 

 

 

 

 

39

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

41

 

 

 

 

 

 

 

42

 

 

 

 

 

 

 

43

 

 

 

 

 

 

 

44

 

 

 

 

 

 

 

45

 

 

 

 

 

 

 

46

 

 

 

 

 

 

 

47

 

 

 

 

 

 

 

48

 

 

 

 

 

 

 

49

 

[1]

 

[BR]

 

 

 

50

 

[1]

 

[BR]

 

 

 

51

 

[1]

 

[BR]

 

 

 

52

 

[1]

 

[BR]

 

 

 

53

 

[1]

 

[BR]

 

 

 

54

 

[1]

 

[BR]

 

 

 

55

 

[1]

 

[BR]

 

 

 

56

 

[1]

 

[BR]

 

 

 

57

 

[1]

 

[BR]

 

 

 

58

 

[1]

 

[BR]

 

 

 

59

 

[1]

 

[BR]

 

 

 

60

 

[1]

 

[BR]

 

 

 

61

 

[1]

 

[BR]

 

 

 

62

 

[1]

 

[BR]

 

 

 

63

 

[1]

 

[BR]

 

 

 

64

 

[1]

 

[BR]

 

 

 

95

[00]

N/A**

 

N/A

N/A

N/A

keypad [1]

/ []

96

[00]

N/A**

 

N/A

N/A

N/A

keypad [3]

/ [#]

99

[06]

N/A**

 

N/A

N/A

N/A

keypad [] / [#]

** Emergency key zones 95, 96, and 99 report the partition of the keypad used to activate the emergency zones.

– 36 –

Image 36
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Programming Mode Commands Installer code + # + 03 enable AVS operationSpecial Messages RF transmittersData Field Programming Form ∗31 ∗32∗33 ∗34∗39 ∗40∗41 ∗42 ∗45 ∗46∗50 ∗53∗54 ∗55∗59 ∗60∗61 ∗62∗66 ∗67∗68 ∗69∗77 ∗78∗84 ∗85∗88 ∗90∗91 ∗93 ∗95∗163 ∗164∗166 ∗167∗171 ∗177∗181 ∗184 ∗185∗191 ∗192∗193 ∗194Configurable Zone Types Worksheets Entries for Fields *182 and *184Entry Zone Type Field *182∗56 Zone Programming Menu Mode Hardwire Type Report Code RCResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Wireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterConfirm Not Confirmed∗57 Function KEY Programming Menu Mode Function KeyPartition Number FA168CPSProgramming Output Devices Output IdentificationDevice Output Number Output Normally Low∗80 Output Function Menu Mode Menu Mode Output Function No Activated ByZone List Zone Type∗81 Zone List Menu Mode Menu Mode Zone List NumberOutput Action Output Number∗82 Alpha Descriptor Menu Mode Descriptor Example ZN 01 Back D OORExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Setting the REAL-TIME Clock Quick Program Command ResultsPre-Programmed #03 Command #04 Command Repeat Option∗29 IP/GSM Program Mode Enable IP/GSM?Diagnostics Select ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesWorksheet for ∗57 Function KEY Programming Worksheet for ∗81 Zone List ProgrammingList No Used For… Contains These Zones… Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSReports as†† Enabled By… Worksheet for SchedulesTable of Device Addresses DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.