First Alert FA148CPSSIA Worksheet for ∗57 Function KEY Programming, Option Function Comments

Page 37

WORKSHEET FOR 57 FUNCTION KEY PROGRAMMING

Option

Function

A

B

C

D

Comments

01

Paging

 

 

 

 

 

02

Time Display

 

 

 

 

 

03

Arm AWAY

 

 

 

 

 

04

Arm STAY

 

 

 

 

 

05

Arm NIGHT-STAY

 

 

 

 

 

06

Step Arming

 

 

 

 

 

07

Device Activation

 

 

 

 

Device:

08

Comm. Test

 

 

 

 

 

09

Macro Key 1

 

 

 

 

 

10

Macro Key 2

 

 

 

 

 

11

Macro Key 3

 

 

 

 

 

12

Macro Key 4

 

 

 

 

 

00

Emergency Keys:

zone 95

zone 99

zone 96

paging

 

 

Personal Emergency

 

 

 

n/a

 

 

Silent Alarm

 

 

 

n/a

 

 

Audible Alarm

 

 

 

n/a

 

 

Fire

 

 

 

n/a

 

Emergency Keys: A = paired keys [1] / [] (zone 95); B = paired keys [] / [#] (zone 99); C = paired keys [3] / [#] (zone 96)

WORKSHEET FOR 79 RELAY/POWERLINE CARRIER (X-10) DEVICE MAPPING

Applicable only if Relays and/or Powerline Carrier Devices are to be used.

Must program before using *80.

 

OUTPUT TYPE

 

 

 

Relay

X10

 

Output

Module

Pos

Unit

Description

No.

Addr.

(1-4)

No.

01

 

 

 

 

02

 

 

 

 

03

 

 

 

 

 

 

 

 

 

04

 

 

 

 

05

 

 

 

 

06

 

 

 

 

 

 

 

 

 

07

 

 

 

 

 

 

 

 

 

08

 

 

 

 

 

OUTPUT TYPE (09-16 apply to FA168CPS only)

 

Relay

X10

 

Output

Module

Pos

Unit

Description

No.

Addr.

(1-4)

No.

09

 

 

 

 

10

11

12

13

14

15

16

17

On-Board Trigger 1

norm output =

18

On-Board Trigger 2

norm output =

 

 

 

WORKSHEET FOR 81 ZONE LIST PROGRAMMING

Fill in the required data on the worksheet below and follow the procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence.

NOTE: Record desired zone numbers below, noting that a list may include any or all of system's zone numbers.

List No.

Used For…

 

Contains These Zones…

 

 

 

 

 

01

General Purpose (GP)

 

 

 

02

General Purpose

 

 

 

03

Chime-by-Zone or GP

 

(see field *26 for Chime-by-Zone option)

04

Cross Zones

 

(see field *85 for Cross Zone Timer option)

05

Night-Stay Zones or GP

 

 

 

06

Dial Delay Disable or GP

 

SIA-Compliant Controls:

see field *50 for Dial Delay Disable option

 

 

 

 

07

Unlimited Reports or GP

 

SIA-Compliant Controls:

see field *93 for Unlimited Reports option

 

 

 

 

 

08

General Purpose

 

 

 

09

Zones activating pager 1

 

 

 

10

Zones activating pager 2

 

 

 

11

Zones activating pager 3

 

(FA168CPS)

12

Zones activating pager 4

 

(FA168CPS)

– 37 –

Image 37
Contents K5305-5PRV5 11/08 Rev. B FA168CPS / FA168CPSSIA FA148CP / FA148CPSIATable of Contents Installer code + # + 03 enable AVS operation Programming Mode CommandsSpecial Messages RF transmittersData Field Programming Form ∗32 ∗31∗33 ∗34∗40 ∗39∗41 ∗42 ∗45 ∗46∗53 ∗50∗54 ∗55∗60 ∗59∗61 ∗62∗67 ∗66∗68 ∗69∗78 ∗77∗84 ∗85∗90 ∗88∗91 ∗95 ∗93∗164 ∗163∗166 ∗167∗177 ∗171∗181 ∗185 ∗184∗192 ∗191∗193 ∗194Entries for Fields *182 and *184 Configurable Zone Types WorksheetsEntry Zone Type Field *182∗56 Zone Programming Menu Mode Report Code RC Hardwire TypeResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates 5804BD 2-Way Wireless Key Transmitter Wireless Key TransmitterConfirm Not ConfirmedFunction Key ∗57 Function KEY Programming Menu ModePartition Number FA168CPSOutput Identification Programming Output DevicesDevice Output Number Output Normally Low∗80 Output Function Menu Mode Activated By Menu Mode Output Function NoZone List Zone TypeMenu Mode Zone List Number ∗81 Zone List Menu ModeOutput Action Output Number∗82 Alpha Descriptor Menu Mode ZN 01 Back D OOR Descriptor ExampleExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Quick Program Command Results Setting the REAL-TIME ClockPre-Programmed #03 Command #04 Command Repeat OptionEnable IP/GSM? ∗29 IP/GSM Program ModeDiagnostics Select ProgrammingZone Type Definitions SIA Quick Reference Guide UL NoticesReserved Zones Worksheet for ∗56 Zone ProgrammingWorksheet for ∗81 Zone List Programming Worksheet for ∗57 Function KEY ProgrammingList No Used For… Contains These Zones… Option Function CommentsFA168CPS Worksheet for ∗80 Output Function ProgrammingWorksheet for Schedules Reports as†† Enabled By…Table of Device Addresses Days5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN Series Transmitter Input Loop Identification

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.