TO PROGRAM SYSTEM STATUS, & RESTORE REPORT CODES (59 thru 68, *70 thru 76, and 89): For 3+1 or 4+1 Standard Format: Enter a code in the first box:

1–9, #+10 for 0, #+11 for B, #+12 for C, #+13 for D, #+14 for E, #+15 for F.

A 0 (not #+10) in the first box disables a report. A 0 (not #+10) in the second box results in advance to the next field. For Expanded or 4+2 Format: Enter codes in both boxes (1st and 2nd digits) for 1–9, 0, or B–F, as described above.

A 0 (not #+10) in the second box will eliminate the expanded message for that report. A 0 (not #+10) in both boxes will disable the report.

For Ademco Contact ID® Reporting: Enter any digit (other than 0) in the first box, to enable zone to report (entries in the second boxes are ignored).A 0 (not #+10) in the first box disables the report.

UL: Report codes are required in fields *61, *65, *71, *72, for UL Commercial Burglar Alarm installations.

Report codes are required in fields *60, *62, *63, *64, *70, *73, *74, *75, *76, for UL Commercial Burglar Alarm installations and required for Residential Fire Alarm installations

SYSTEM STATUS REPORT CODES (59–68)

59

 

 

Exit Error Alarm Report Code

 

 

 

See above for entries.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SIA-Compliant Controls:

 

 

 

 

[1] Always enabled.

 

 

[0]

After arming the system, entry/exit and interior zones remaining open after exit delay expires cause an alarm sound at the keypad and external sounder (keypad also displays “EXIT ALARM”), and entry delay begins. Disarming before the end of the entry delay stops the alarm sounding and no message is sent to the central station. The keypad will display “CA” (fixed-word) or “ALARM CANCELED” (alpha display).

If the system is not disarmed before entry delay expires, an “EXIT ALARM” message (SIA-Compliant Controls: also zone alarm message) will be sent to the central station. The keypad will display “EA” (fixed-word ) or “EXIT ALARM” (alpha display), and alarm sounding continues until the system is disarmed (or timeout occurs).

An Exit Alarm condition will also result if a fault occurs in an exit or interior zone within 2 minutes following the end of the exit delay, and an “EXIT ALARM” message will be sent to the central station (except for SIA-Compliant Controls, see field *69 Recent Closing report). With Contact ID format, the message will contain the zone number and error code 374 (“ALARM–EXIT ERROR”).

60

Trouble Report Code

 

 

[10]

See above for entries.

Sent if a zone has a trouble condition.

See UL System Reporting Note above *59.

61

Bypass Report Code

 

 

[00]

See above for entries.

Sent when a zone is manually bypassed.

See UL System Reporting Note above *59.

62

AC Loss Report Code

 

See above for entries.

[10]

Timing of this report is random with up to a 4-hour delay. If AC restores before the report goes out, there is no “AC LOSS” report.

See UL System Reporting Note above *59.

63

Low Bat Report Code

 

[10]

See above for entries.

Sent when the system’s backup battery has a low-battery condition.

See UL System Reporting Note above *59

64 Test Report Code

See above for entries.

Periodic Test Report Scheduling Commands:

installer code +[#] + [0] + 0 = report every 24 hrs

installer code +[#] + [0] + 1 = report once per week

installer code +[#] + [0] + 2 = report every 28 days

[00]

Sent periodically to test that the communicator and phone lines are operational.

Frequency of report is set in Scheduling mode (event 11) or by the key commands listed at left:

Each mode sets schedule 32 (FA168CPS) or schedule 08 (FA148CP) to the stated repeat option; first test report sent 12 hours after command.

See System Reporting UL Note above *59.

NOTE: Make sure the Real-Time Clock is set to the proper time before entering the test report schedule command to ensure that test reports are sent when expected. (see Setting the Real-Time Clock section)

65

Open Report Code

 

 

[0,0,0]

 

 

 

See above for entries.

 

 

Common

 

 

 

Part. 1 Part. 2

Sent upon disarming the system in the selected partitions.

See UL System Reporting Note above *59.

– 8 –

Image 8
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Programming Mode Commands Installer code + # + 03 enable AVS operationSpecial Messages RF transmittersData Field Programming Form ∗31 ∗32∗33 ∗34∗39 ∗40∗41 ∗42 ∗45 ∗46∗50 ∗53∗54 ∗55∗59 ∗60∗61 ∗62∗66 ∗67∗68 ∗69∗77 ∗78∗84 ∗85∗91 ∗88∗90 ∗93 ∗95∗163 ∗164∗166 ∗167∗181 ∗171∗177 ∗184 ∗185∗191 ∗192∗193 ∗194Configurable Zone Types Worksheets Entries for Fields *182 and *184Entry Zone Type Field *182∗56 Zone Programming Menu Mode Hardwire Type Report Code RCResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Wireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterConfirm Not Confirmed∗57 Function KEY Programming Menu Mode Function KeyPartition Number FA168CPSProgramming Output Devices Output IdentificationDevice Output Number Output Normally Low∗80 Output Function Menu Mode Menu Mode Output Function No Activated ByZone List Zone Type∗81 Zone List Menu Mode Menu Mode Zone List NumberOutput Action Output Number∗82 Alpha Descriptor Menu Mode Descriptor Example ZN 01 Back D OORExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Setting the REAL-TIME Clock Quick Program Command ResultsPre-Programmed #03 Command #04 Command Repeat Option∗29 IP/GSM Program Mode Enable IP/GSM?Diagnostics Select ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesWorksheet for ∗57 Function KEY Programming Worksheet for ∗81 Zone List ProgrammingList No Used For… Contains These Zones… Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSReports as†† Enabled By… Worksheet for SchedulesTable of Device Addresses DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.