Page 22

XMIT TO CONFIRM PRESS TO SKIP

Confirm

If “Yes” was entered at the SET TO CONFIRM? prompt

[] to continue

previously (see first prompt following entry into the 58

 

Expert Programming Mode), the display on the left will

 

appear. Confirm serial and loop numbers by activating the

 

wireless key.

 

 

 

 

IMPORTANT:

 

 

 

 

When confirmed, the key is not active for arming/disarming until

 

 

 

 

it is assigned to a user number (using the assigning attributes

 

 

 

 

command, attribute “4”). See System Operation section for

 

 

 

 

procedure.

 

 

 

Not Confirmed

If the serial number transmitted does not match the serial

 

Entd

A022-4063

 

[] to continue

number entered, a display similar to the one shown will appear.

 

Rcvd

A022-4064

 

 

If the loop number does not match, it will also be displayed.

 

 

 

 

 

If so, activate the button on the wireless key once again. If a match is not obtained (i.e., summary display does not appear), press the [#] key and then enter the correct serial number.

If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and will return you to the Zone Number prompt to enter the starting zone for the next wireless key.

Or you can return to *58 Menu mode by pressing 00 at the Zone Number prompt.

NOTE: Following the successful enrollment of each wireless device, remove ONE of the serial number labels from the device and affix it in the appropriate column on the ZONE PROGRAMMING worksheet of the Programming Form; then enter the other information (zone number, zone type, loop number, etc.) relevant to that device.

Wireless Key Predefined Default Templates

 

 

LOOP 3

YOU MUST

OFF

LOOP 2

PROGRAM

ON

 

THIS BUTTON

 

LOOP 1

LOOP 4

 

ENROLL AS "BR"

5 8 0 4 - 0 0 1 - V 1

5804 Wireless Key Transmitter

Note:

These transmitters are not intended for use in UL installations.

GREEN/YELLOW

 

 

 

LED

 

 

LOOP 2

RED/YELLOW

 

 

LOOP 4

LED

 

 

 

 

(YOU MUST

 

 

 

 

 

 

PROGRAM

 

 

 

THIS BUTTON)

LOOP 3

 

 

 

 

 

 

LOOP 1

• •

•••

••

ENROLL AS "BR"

••

 

 

 

5 8 0 4 B D - 0 0 7 - V 0

5804BD 2-Way Wireless Key

Transmitter

 

For 5804

 

 

 

For 5804BD

 

TEMPLATE 1

Loop

Function

Zone Type

 

TEMPLATE 4

Loop

Function

Zone Type

 

1

No Response

23

 

 

1

No Response

23

 

2

Disarm

22

 

 

2

No Response

23

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

No Response

23

 

 

4

Disarm

22

TEMPLATE 2

Loop

Function

Zone Type

 

TEMPLATE 5

Loop

Function

Zone Type

 

1

No Response

23

 

 

1

No Response

23

 

2

Disarm

22

 

 

2

Arm Stay

20

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

Arm Stay

20

 

 

4

Disarm

22

TEMPLATE 3

Loop

Function

Zone Type

 

TEMPLATE 6

Loop

Function

Zone Type

 

1

24-hour audible

7

 

 

1

24-hour audible

7

 

2

Disarm

22

 

 

2

Arm Stay

20

 

3

Arm Away

21

 

 

3

Arm Away

21

 

4

Arm Stay

20

 

 

4

Disarm

22

– 22 –

Image 22
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Special Messages Programming Mode CommandsInstaller code + # + 03 enable AVS operation RF transmittersData Field Programming Form ∗33 ∗31∗32 ∗34∗41 ∗42 ∗39∗40 ∗45 ∗46∗54 ∗50∗53 ∗55∗61 ∗59∗60 ∗62∗68 ∗66∗67 ∗69∗84 ∗77∗78 ∗85∗90 ∗88∗91 ∗93 ∗95∗166 ∗163∗164 ∗167∗177 ∗171∗181 ∗184 ∗185∗193 ∗191∗192 ∗194Entry Zone Type Configurable Zone Types WorksheetsEntries for Fields *182 and *184 Field *182∗56 Zone Programming Menu Mode Response Time RT Hardwire Type Report Code RC Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Confirm Wireless Key Transmitter5804BD 2-Way Wireless Key Transmitter Not ConfirmedPartition Number ∗57 Function KEY Programming Menu ModeFunction Key FA168CPSDevice Output Number Programming Output DevicesOutput Identification Output Normally Low∗80 Output Function Menu Mode Zone List Menu Mode Output Function NoActivated By Zone TypeOutput Action ∗81 Zone List Menu ModeMenu Mode Zone List Number Output Number∗82 Alpha Descriptor Menu Mode Example Back Door Descriptor ExampleZN 01 Back D OOR ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Pre-Programmed #03 Command #04 Command Setting the REAL-TIME ClockQuick Program Command Results Repeat OptionDiagnostics Select ∗29 IP/GSM Program ModeEnable IP/GSM? ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesList No Used For… Contains These Zones… Worksheet for ∗57 Function KEY ProgrammingWorksheet for ∗81 Zone List Programming Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSTable of Device Addresses Reports as†† Enabled By…Worksheet for Schedules DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN