CONFIGURABLE ZONE TYPES WORKSHEETS

Configurable zone types 90 and 91 can be programmed via downloader software or from a keypad using data fields*182-*185. Configurable zone types 92 and 93 (FA168CPS only) can only be programmed using the downloader software.

Programming Configurable Zone Type options involves making 10 entries in data field *182 for zone type 90 and field *184 for zone type 91, where each entry represents the sum of the values of the various options shown in the tables below. Use fields *183 and *185 to program Contact ID report codes for these zone types.

ENTRY 1 (See note 5 for RF zones) ENTRY 2 (See note 5 for RF zones)

Response when system disarmed and zone is:

 

 

Auto

 

 

 

 

 

Intact EOL

 

 

Open

 

 

Shorted

 

 

Restore

 

 

Vent Zone

 

RF zone normal

 

 

RF zone N/A

 

RF zn off-normal

 

 

 

 

 

 

 

0

= normal

 

0

= normal

 

0

= normal

 

0

= no

 

0

= no

 

1

= alarm

 

4

= alarm

 

1

= alarm

 

4

= yes

 

8

= yes

 

2

= trouble

 

8

= trouble

 

2

= trouble

 

 

 

 

 

 

 

3

= fault

 

12 = fault

 

3

= fault

 

 

 

 

 

 

 

Entry 1 = EOL +

 

Open

 

Entry 2 = Short + auto restore + vent zone

 

 

 

 

 

 

 

 

ENTRY 3 (See note 5 for RF zones)

 

ENTRY 4 (See note 5 for RF zones)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Response when armed STAY and zone is:

 

 

Byp. when

 

 

Byp. when

 

 

Intact EOL

 

 

Open

 

 

Shorted

 

 

disarmed

 

 

armed

 

RF zone normal

 

 

RF zone N/A

 

RF zn off-normal

 

 

 

 

 

 

 

0

= normal

 

0

= normal

 

0

= normal

 

0

= no

 

0

= no

 

1

= alarm

 

4

= alarm

 

1

= alarm

 

4

= yes

 

8

= yes

 

2

= trouble

 

8

= trouble

 

2

= trouble

 

 

 

 

 

 

 

3

= fault

 

12 = fault

 

3

= fault

 

 

 

 

 

 

 

Entry 3 = EOL +

 

Open

 

Entry 4 = Short + byp. disarmed + byp. armed

 

ENTRY 5 (See note 5 for RF zones) ENTRY 6 (See note 5 for RF zones)

Response when armed AWAY and zone is:

 

 

Dial Delay

 

 

Fault Delay

 

Intact EOL

 

 

Open

 

 

Shorted

 

(see field *50)

 

(see field *87)

RF zone normal

 

 

RF zone N/A

 

RF zn off-normal

 

 

 

 

 

 

0

= normal

 

0

= normal

 

0

= normal

 

0

= no

 

0

= no

1

= alarm

 

4

= alarm

 

1

= alarm

 

4

= use delay

 

8

= use delay

2

= trouble

 

8

= trouble

 

2

= trouble

 

 

 

 

 

 

3

= fault

 

12 = fault

 

3

= fault

 

 

 

 

see note 1

Entry 5 = EOL +

 

Open

 

Entry 6 = Short + dial delay + fault delay

 

ENTRY 7

 

 

 

ENTRY 8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Display Faults

 

Power Reset/

 

Use Entry

 

Use Exit

 

Respond as

 

 

 

Verification

 

Delay 1/2

 

Delay

 

Interior Type

 

0 = show alarms

 

0 = no

 

0 = no

 

0 = no

 

0 = no

 

when armed

 

4 = power reset

 

1 = delay 1

 

4 = use exit

 

8 = yes

 

& disarmed

 

after fault

 

2 = delay 2

 

delay

 

see note 2

 

1 = don’t show

 

(by code + OFF)

 

 

 

 

 

 

alarms when

 

12 = verification

 

 

 

 

 

 

 

armed (show

 

(see zone

 

 

 

 

 

 

 

alarms, trbles,

 

type 16)

 

 

 

 

 

 

 

faults when

 

 

 

 

 

 

 

 

 

disarmed)

 

 

 

 

 

 

 

 

 

3 = never show

 

 

 

 

 

 

 

 

 

any alarms,

 

 

 

 

 

 

 

 

 

trbles, faults

 

 

 

 

 

 

 

 

 

Entry 7 = fault display + power

 

Entry 8 = entry delay 1/entry delay 2 + exit delay +

 

reset/verification

 

 

 

interior zone type

 

 

 

 

 

ENTRY 9

 

 

 

 

 

ENTRY 10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Alarm Sounds

 

Use Bell

 

Respond as

 

 

Trouble

 

Chime when

 

 

 

 

Timeout

 

Fire Zone

 

 

Sounds

 

Chime Mode On

0

= none

 

0 = no

 

0 = no

 

0

= none

 

0 = no

1

= steady

 

4 = yes

 

8 = yes

 

1

= periodic

 

4 = yes

 

 

keypad

 

 

 

 

 

 

beep

 

 

2

= steady bell

 

see fields *32,

 

see zone type

 

2

= trouble

 

 

 

 

and keypad

 

*33

 

09; see note 4

 

 

beeps

 

 

3

= pulsing bell

 

 

 

 

 

 

 

 

 

 

 

and keypad

 

 

 

 

 

 

 

 

 

 

Entry 9 = alarm

 

sounds + bell timeout + fire zone

 

Entry 10 = trouble sounds + chime

Entries for Fields *182 and *184

Entry Zone Type 90

Zone Type 91

(field *182)

(field *184)

1

2

3

4

5

6

7

8

9

10

To calculate the value for each entry: Simply add the values of the selected options in each of the entry’s columns (one option per column). For example, to program Entry 2 for “alarm response to short,” “auto restore on,” but not a “vent zone,” enter 5 (“1” for alarm short + “4” for auto restore yes + “0” for vent zone no).

INTACT

OPEN

SHORTED

EOL

 

 

 

 

ZONE-003-V0

Zone Conditions Represented

in Entries 1-6

NOTES:

1.Do not use the “fault delay” option with a configurable zone type if it is set for an entry or exit delay, otherwise unpredictable results may occur.

2.To create an interior type zone, select “respond as interior zone type” (entry 8, interior type = yes), and set zone response to “fault” in entries 3-4 to ensure fault displays; do not set as “normal,” “alarm,” or “trouble.”

3.Do not set fire zones to respond as a

“fault” (entries 1-6), otherwise faults will not display unless the [] key is pressed.

4.4219/4229 modules must use EOLRs or unpredictable results may occur.

5.RF Zones: The “open” option in entries 1, 3, and 5 is not applicable for RF zones. Use the “intact EOL” option for normal RF zone conditions and “shorted” for off- normal RF zone conditions.

6.a. Zone-Doubling/Double-Balanced: A short on either zone of a zone-doubled pair or on a double-balanced zone causes a tamper condition.

b.For double-balanced zones, this entry must be “0.”

c.For zone-doubled zones, both zones of the doubled pair must be assigned the same response to a short.

– 17 –

Image 17
Contents K5305-5PRV5 11/08 Rev. B FA168CPS / FA168CPSSIA FA148CP / FA148CPSIATable of Contents Installer code + # + 03 enable AVS operation Programming Mode CommandsSpecial Messages RF transmittersData Field Programming Form ∗32 ∗31∗33 ∗34∗40 ∗39∗41 ∗42 ∗45 ∗46∗53 ∗50∗54 ∗55∗60 ∗59∗61 ∗62∗67 ∗66∗68 ∗69∗78 ∗77∗84 ∗85∗91 ∗88∗90 ∗95 ∗93∗164 ∗163∗166 ∗167∗181 ∗171∗177 ∗185 ∗184∗192 ∗191∗193 ∗194Entries for Fields *182 and *184 Configurable Zone Types WorksheetsEntry Zone Type Field *182∗56 Zone Programming Menu Mode Report Code RC Hardwire TypeResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates 5804BD 2-Way Wireless Key Transmitter Wireless Key TransmitterConfirm Not ConfirmedFunction Key ∗57 Function KEY Programming Menu ModePartition Number FA168CPSOutput Identification Programming Output DevicesDevice Output Number Output Normally Low∗80 Output Function Menu Mode Activated By Menu Mode Output Function NoZone List Zone TypeMenu Mode Zone List Number ∗81 Zone List Menu ModeOutput Action Output Number∗82 Alpha Descriptor Menu Mode ZN 01 Back D OOR Descriptor ExampleExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Quick Program Command Results Setting the REAL-TIME ClockPre-Programmed #03 Command #04 Command Repeat OptionEnable IP/GSM? ∗29 IP/GSM Program ModeDiagnostics Select ProgrammingZone Type Definitions SIA Quick Reference Guide UL NoticesReserved Zones Worksheet for ∗56 Zone ProgrammingWorksheet for ∗81 Zone List Programming Worksheet for ∗57 Function KEY ProgrammingList No Used For… Contains These Zones… Option Function CommentsFA168CPS Worksheet for ∗80 Output Function ProgrammingWorksheet for Schedules Reports as†† Enabled By…Table of Device Addresses Days5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN Series Transmitter Input Loop Identification

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.