First Alert FA148CPSSIA manual Setting the REAL-TIME Clock, Repeat Option, Randomize

Page 32

REPEAT OPTION

0 - 4X

Repeat Option

0 = do not repeat

1 = repeat weekly

2 = repeat biweekly (every other week)

3 = repeat every third week

4 = repeat every fourth week Press [] to continue.

Enter the desired repeat option for this schedule.

e.g., To make a schedule that happens everyday you would select all days with a repeat count of 1. To make a schedule that runs for one week then stops, select everyday with a repeat count of 0.

RANDOMIZE

0 = N O 1 = YE S X

Randomize

0 = no

1 = yes

Press [] to continue and return to ENTER SCHED NO. prompt to program the next schedule.

(For events 01 and 11)

If selected, the scheduled start and stop times will vary within 60 minutes of the “hour” time. For example, if a schedule is set to start at 6:15pm, it will do so the first time 6:15pm arrives, but on subsequent days it will start anytime between 6:00 and 6:59 p.m.

NOTE: Do not use the random option if the start and stop times are within the same “hour” setting, otherwise unpredictable results may occur (e.g., the randomized stop time may occur before the start time).

AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS

Applies to an AVS system using an ECP connection to the control.

1.Install the AVS module according to its instructions.

2.Use one of the control’s AVS Quick Program commands as follows (see Quick Program Command Results below for results of each command):

installer code + [#] + 0 + 3: enable AVS operation without panel sounds on the AVST speaker

installer code + [#] + 0 + 4: enable AVS operation and enable panel sounds on the AVST speaker

3.Use data field 55 Dynamic Signaling Priority to select the desired reporting paths (phone line and/or GSMV) and path for AAV communication.

4.To undo the Quick Command programming, use the following commands:

installer code + [#] + 0 + 5: remove all options that were set if [#] + 03 quick command was performed

installer code + [#] + 0 + 6: remove all options that were set if [#] + 04 quick command was performed

Quick Program Command Results

When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer available for other control panel purposes.

Pre-Programmed

#03 Command

 

#04 Command

Output Function No.

FA148CP

FA168CPS

FA148CP

FA168CPS

(80 mode)

22 (zone type 60, relay 07)

46 (zone type 60, relay 15)

Same as #03 plus:

Same as #03 plus:

 

23 (zone type 61, relay 08)

47 (zone type 61, relay 16)

17

(zone type 14, relay 05)

41

(zone type 14, relay 13)

 

24 (zone type 62, relay 08)

48 (zone type 62, relay 16)

18

(zone type 22, relay 05)

42

(zone type 22, relay 13)

 

 

 

19

(zone type 39, relay 06)

43

(zone type 39, relay 14)

 

 

 

20

(zone type 33, relay 06)

44

(zone type 33, relay 14)

 

 

 

21

(zone type 22, relay 06)

45

(zone type 22, relay 14

Output Relay No.

07 (addr 08, relay pos 2)

15 (addr 11, relay pos 2)

Same as #03 plus:

Same as #03 plus:

(79 mode)

08 (addr 08, relay pos 1)

16 (addr 11, relay pos 1)

05

(addr 08, relay pos 4)

13

(addr 11, relay pos 4)

 

 

 

06

(addr 08, relay pos 3)

14

(addr 11, relay pos 3)

Protection Zone

4229 zn 24 (zt 81, addr 08)

4229 zn 48 (zt 81, addr 11)

Same as #03 command

Same as #03 command

(56/58 mode)

 

 

 

 

 

 

Device Address

address 08 (AVS module)

address 11 (AVS module)

Same as #03 command

Same as #03 command

Data Field 91

AAV enabled

AAV enabled

 

AAV enabled

 

AAV enabled

SETTING THE REAL-TIME CLOCK

IMPORTANT: The Real-Time Clock must be set before the end of the installation.

NOTE: All partitions must be disarmed before the date/time can be set.

1.Master Code + [#] + [6] [3]

2.Press [] when the time/date is displayed.

A cursor appears under the first digit of the hour.

To move cursor ahead, press []. To go back, press [#].

Enter the 2-digit hour setting.

Enter the 2-digit minute setting.

Press [1] for PM or [2] for AM.

Enter the last two digits of the current year.

Enter the 2-digit month setting.

Enter the 2-digit day setting.

3.To exit, press [] when cursor is at the last digit, or wait 30 seconds.

32 –

Image 32
Contents FA168CPS / FA168CPSSIA FA148CP / FA148CPSIA K5305-5PRV5 11/08 Rev. BTable of Contents Programming Mode Commands Installer code + # + 03 enable AVS operationSpecial Messages RF transmittersData Field Programming Form ∗31 ∗32∗33 ∗34∗39 ∗40∗41 ∗42 ∗45 ∗46∗50 ∗53∗54 ∗55∗59 ∗60∗61 ∗62∗66 ∗67∗68 ∗69∗77 ∗78∗84 ∗85∗91 ∗88∗90 ∗93 ∗95∗163 ∗164∗166 ∗167∗181 ∗171∗177 ∗184 ∗185∗191 ∗192∗193 ∗194Configurable Zone Types Worksheets Entries for Fields *182 and *184Entry Zone Type Field *182∗56 Zone Programming Menu Mode Hardwire Type Report Code RCResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates Wireless Key Transmitter 5804BD 2-Way Wireless Key TransmitterConfirm Not Confirmed∗57 Function KEY Programming Menu Mode Function KeyPartition Number FA168CPSProgramming Output Devices Output IdentificationDevice Output Number Output Normally Low∗80 Output Function Menu Mode Menu Mode Output Function No Activated ByZone List Zone Type∗81 Zone List Menu Mode Menu Mode Zone List NumberOutput Action Output Number∗82 Alpha Descriptor Menu Mode Descriptor Example ZN 01 Back D OOR Example Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Setting the REAL-TIME Clock Quick Program Command ResultsPre-Programmed #03 Command #04 Command Repeat Option∗29 IP/GSM Program Mode Enable IP/GSM?Diagnostics Select ProgrammingZone Type Definitions UL Notices SIA Quick Reference GuideWorksheet for ∗56 Zone Programming Reserved ZonesWorksheet for ∗57 Function KEY Programming Worksheet for ∗81 Zone List ProgrammingList No Used For… Contains These Zones… Option Function CommentsWorksheet for ∗80 Output Function Programming FA168CPSReports as†† Enabled By… Worksheet for SchedulesTable of Device Addresses DaysSeries Transmitter Input Loop Identification 5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN