REPEAT OPTION
0 - 4X
Repeat Option
0 = do not repeat
1 = repeat weekly
2 = repeat biweekly (every other week)
3 = repeat every third week
4 = repeat every fourth week Press [∗] to continue.
Enter the desired repeat option for this schedule.
e.g., To make a schedule that happens everyday you would select all days with a repeat count of 1. To make a schedule that runs for one week then stops, select everyday with a repeat count of 0.
RANDOMIZE
0 = N O 1 = YE S X
Randomize
0 = no
1 = yes
Press [∗] to continue and return to ENTER SCHED NO. prompt to program the next schedule.
(For events 01 and 11)
If selected, the scheduled start and stop times will vary within 60 minutes of the “hour” time. For example, if a schedule is set to start at 6:15pm, it will do so the first time 6:15pm arrives, but on subsequent days it will start anytime between 6:00 and 6:59 p.m.
NOTE: Do not use the random option if the start and stop times are within the same “hour” setting, otherwise unpredictable results may occur (e.g., the randomized stop time may occur before the start time).
AVS SYSTEM ENABLE and QUICK PROGRAMMING COMMANDS
Applies to an AVS system using an ECP connection to the control.
1.Install the AVS module according to its instructions.
2.Use one of the control’s AVS Quick Program commands as follows (see Quick Program Command Results below for results of each command):
•installer code + [#] + 0 + 3: enable AVS operation without panel sounds on the AVST speaker
•installer code + [#] + 0 + 4: enable AVS operation and enable panel sounds on the AVST speaker
3.Use data field ∗55 Dynamic Signaling Priority to select the desired reporting paths (phone line and/or GSMV) and path for AAV communication.
4.To undo the Quick Command programming, use the following commands:
•installer code + [#] + 0 + 5: remove all options that were set if [#] + 03 quick command was performed
•installer code + [#] + 0 + 6: remove all options that were set if [#] + 04 quick command was performed
Quick Program Command Results
When either the #03 or #04 Quick Program command is used, the following are automatically programmed and no longer available for other control panel purposes.
| #03 Command |
| #04 Command | |||
Output Function No. | FA148CP | FA168CPS | FA148CP | FA168CPS | ||
(∗80 mode) | 22 (zone type 60, relay 07) | 46 (zone type 60, relay 15) | Same as #03 plus: | Same as #03 plus: | ||
| 23 (zone type 61, relay 08) | 47 (zone type 61, relay 16) | 17 | (zone type 14, relay 05) | 41 | (zone type 14, relay 13) |
| 24 (zone type 62, relay 08) | 48 (zone type 62, relay 16) | 18 | (zone type 22, relay 05) | 42 | (zone type 22, relay 13) |
|
|
| 19 | (zone type 39, relay 06) | 43 | (zone type 39, relay 14) |
|
|
| 20 | (zone type 33, relay 06) | 44 | (zone type 33, relay 14) |
|
|
| 21 | (zone type 22, relay 06) | 45 | (zone type 22, relay 14 |
Output Relay No. | 07 (addr 08, relay pos 2) | 15 (addr 11, relay pos 2) | Same as #03 plus: | Same as #03 plus: | ||
(∗79 mode) | 08 (addr 08, relay pos 1) | 16 (addr 11, relay pos 1) | 05 | (addr 08, relay pos 4) | 13 | (addr 11, relay pos 4) |
|
|
| 06 | (addr 08, relay pos 3) | 14 | (addr 11, relay pos 3) |
Protection Zone | 4229 zn 24 (zt 81, addr 08) | 4229 zn 48 (zt 81, addr 11) | Same as #03 command | Same as #03 command | ||
(∗56/∗58 mode) |
|
|
|
|
|
|
Device Address | address 08 (AVS module) | address 11 (AVS module) | Same as #03 command | Same as #03 command | ||
Data Field ∗91 | AAV enabled | AAV enabled |
| AAV enabled |
| AAV enabled |
SETTING THE REAL-TIME CLOCK
IMPORTANT: The
NOTE: All partitions must be disarmed before the date/time can be set.
1.Master Code + [#] + [6] [3]
2.Press [∗] when the time/date is displayed.
A cursor appears under the first digit of the hour.
To move cursor ahead, press [∗]. To go back, press [#].
•Enter the
•Enter the
•Press [1] for PM or [2] for AM.
•Enter the last two digits of the current year.
•Enter the
•Enter the
3.To exit, press [∗] when cursor is at the last digit, or wait 30 seconds.