First Alert FA148CPSSIA ∗29 IP/GSM Program Mode, Enable IP/GSM?, Programming, Diagnostics Select

Page 33

29 COMMUNICATION DEVICE MENU MODE (Pass-Through Programming)

This mode is for programming an IP, GSM, or IP/GSM Communicator Module using an alpha keypad. Alternatively, these options can be programmed via the AlarmNet Direct website. After programming is complete, the module must be registered with AlarmNet before reporting via the communication device can occur. Refer to the device’s instructions for registration procedures.

NOTE: The module must be set to device address 3.

IMPORTANT: The use of an IP/GSM Communicator Module requires an AlarmNet–I account. Please obtain the account information from the central station prior to programming this module.

Using an Alpha Keypad as a 7720P Programming Tool

When programming with 29 menu mode, the alpha keypad mimics the functions of the 7720P Programming Tool. See figure to right and table below for 7720P key functions. Each key has two possible functions: a normal function and a SHIFT function.

Normal functions: The numeric values labeled directly on the keys and the left-hand functions shown in diagram on the ABC keys. To perform a normal key function, simply press the desired key.

SHIFT functions: Those functions shown in diagram above the numerical keys and the right-hand functions shown on the ABC keys. To perform a SHIFT key function, press SHIFT key (D key), then press the desired function key (shift function is indicated by the lit READY LED).

ARMED READY

SHIFT

FUNCTION

WHEN LIT

 

 

4 MAX

R

6BYPASS

(B)

/

5 TEST

(A)

 

 

B

C

BS/ESC

1OFF

2 AWAY

3 STAY

(C)

N / Y

7INSTANT

8 CODE

9 CHIME

 

 

D

E

F

 

 

SPACEREADY

T

X

(D)

SHIFT

0

ENTER#

FA 5 6 0

FA560KP-005-V0

7720P Emulation Template for Alpha Keypads

29 IP/GSM Program Mode

Press 29 while in Data Field Programming mode. The following prompts appear.

ENABLE IP/GSM? 0=No, 1=Yes

Enable IP/GSM?

0 = no, not using IP or GSM;

1 = yes using IP and/or GSM module

[] to continue

If using a communication device, enter 1 at this prompt and enter 1-Prog at the next prompt to program and register the device. Use the communication device’s Installation Guide for details of the device’s programming prompts and instructions for registration.

[Default = 0 (no IP and/or GSM)]

 

 

 

Programming /

Select whether you want to program the communication device

1=PROG 2=DIAG

Diagnostics Select

or enter the device’s diagnostic mode.

0=QUIT

1= Prog (program the

 

 

 

 

 

 

Diagnostic Mode Note: Diagnostic mode option available only

 

 

 

 

 

 

IP/GSM options)

 

 

 

for communicators with firmware version 2.4.16 or higher.

 

 

 

2 = Diag (enter diagnostic

 

 

 

mode)

 

 

 

 

 

 

0 = Quit; returns to data field

 

 

 

 

 

 

programming mode

 

 

 

 

Normal and SHIFT key Functions While in 29 Menu Mode

 

 

 

Key

 

Normal Key Function

 

SHIFT Key Function

 

 

(A) = BS/ESC

 

[BS]: Press to delete entry

 

[ESC]: Press to quit Program Mode

 

 

 

 

Also, can reset EEPROM defaults †

 

 

 

(B) = /

 

[]: Scroll down programming

 

[]: Scroll up programming

 

 

(C) = N/Y

 

[N]: Press for "NO" answer

 

[Y]: Press SHIFT-Y for "YES" answer

 

 

(D) = SHIFT

 

Press before pressing a SHIFT key function. Will light READY LED. LED goes out once a

 

 

 

 

key is pressed. Press again for each SHIFT function desired.

 

 

1/A

 

[1]: For entering the number 1

 

[A]: Used for entering C.S. ID number

 

 

2/B

 

[2]: For entering the number 2

 

[B]: Used for entering C.S. ID number

 

 

3/C

 

[3]: For entering the number 3

 

[C]: Used for entering C.S. ID number

 

 

4/D

 

[4]: For entering the number 4

 

[D]: Used for entering C.S. ID number

 

 

5/E

 

[5]: For entering the number 5

 

[E]: Used for entering C.S. ID number

 

 

6/F

 

[6]: For entering the number 6

 

[F]: Used for entering C.S. ID number

 

 

7/S

 

[7]: For entering the number 7

 

[S]: Press to display diagnostic status

 

 

8/T

 

[8]: For entering the number 8

 

[T]: Press to send TEST messages

 

 

9/X

 

[9]: For entering the number 9

 

[X]: Press to reset the IP/GSM

 

 

[] / SPACE

 

[]: Used to select programming options

[SPACE]: Not used

 

 

0

 

[0]: For entering the number 0

 

 

 

 

[#] / ENTER

 

[#] / ENTER: Press to accept entries

No SHIFT function

 

Active only when the "REVIEW?" prompt is displayed

33 –

Image 33
Contents K5305-5PRV5 11/08 Rev. B FA168CPS / FA168CPSSIA FA148CP / FA148CPSIATable of Contents Installer code + # + 03 enable AVS operation Programming Mode CommandsSpecial Messages RF transmittersData Field Programming Form ∗32 ∗31∗33 ∗34∗40 ∗39∗41 ∗42 ∗45 ∗46∗53 ∗50∗54 ∗55∗60 ∗59∗61 ∗62∗67 ∗66∗68 ∗69∗78 ∗77∗84 ∗85∗88 ∗90∗91 ∗95 ∗93∗164 ∗163∗166 ∗167∗171 ∗177∗181 ∗185 ∗184∗192 ∗191∗193 ∗194Entries for Fields *182 and *184 Configurable Zone Types WorksheetsEntry Zone Type Field *182∗56 Zone Programming Menu Mode Report Code RC Hardwire TypeResponse Time RT Input Device type∗58 Expert Zone Program Mode Wireless KEY Programming Templates 5804BD 2-Way Wireless Key Transmitter Wireless Key TransmitterConfirm Not ConfirmedFunction Key ∗57 Function KEY Programming Menu ModePartition Number FA168CPSOutput Identification Programming Output DevicesDevice Output Number Output Normally Low∗80 Output Function Menu Mode Activated By Menu Mode Output Function NoZone List Zone TypeMenu Mode Zone List Number ∗81 Zone List Menu ModeOutput Action Output Number∗82 Alpha Descriptor Menu Mode ZN 01 Back D OOR Descriptor ExampleExample Back Door ZN 01 Back DoorCharacter Ascii Chart For Adding Custom Words Setting Schedules Quick Program Command Results Setting the REAL-TIME ClockPre-Programmed #03 Command #04 Command Repeat OptionEnable IP/GSM? ∗29 IP/GSM Program ModeDiagnostics Select ProgrammingZone Type Definitions SIA Quick Reference Guide UL NoticesReserved Zones Worksheet for ∗56 Zone ProgrammingWorksheet for ∗81 Zone List Programming Worksheet for ∗57 Function KEY ProgrammingList No Used For… Contains These Zones… Option Function CommentsFA168CPS Worksheet for ∗80 Output Function ProgrammingWorksheet for Schedules Reports as†† Enabled By…Table of Device Addresses Days5800CO 5800Micra 5800SS1 5800WAVE 5801 5802 MN Series Transmitter Input Loop Identification

FA148CPSSIA specifications

First Alert FA148CPSSIA is a premium smoke and carbon monoxide detector that stands out for its advanced features and technologies, designed to enhance home safety. This innovative device provides dual protection against two of the most dangerous threats faced in homes: smoke from potential fires and carbon monoxide, a silent killer that is odorless and colorless.

One of the main features of the FA148CPSSIA is its voice alert system. This device does not just sound an alarm; it provides an intelligible voice alert that appraises homeowners on the specific type of danger. This feature allows users to quickly identify whether they are facing a smoke or carbon monoxide event, enabling them to respond more effectively.

Furthermore, the FA148CPSSIA is equipped with a 10-year lithium battery, which means that homeowners do not have to worry about battery replacements for over a decade. This feature not only makes the device more convenient but also ensures continual protection without frequent maintenance. The unit is designed with a low battery chirp alert, reminding users when it is time to replace or recharge the entire unit.

Another remarkable aspect of the FA148CPSSIA is its SmartHome compatibility. The unit can connect with various smart home systems, allowing users to monitor the device and receive alerts on their mobile devices. This integration makes for a holistic approach to home safety, as homeowners can receive real-time notifications whether they are at home or away.

The First Alert FA148CPSSIA features a sleek and modern design that allows it to blend seamlessly into any home décor. Its compact form factor allows for easy installation in various places around the house, including bedrooms, hallways, and kitchens.

In terms of technology, the FA148CPSSIA employs photoelectric smoke sensing technology, which is effective in detecting smoldering fires while reducing the likelihood of false alarms. This advanced sensing capability ensures that users are alerted to real dangers without unnecessary interruptions.

Overall, the First Alert FA148CPSSIA is a feature-rich, reliable, and user-friendly smoke and carbon monoxide detector. Its combination of voice alerts, long-lasting battery, smart connectivity, and advanced sensing technology makes it an ideal choice for enhancing home safety and ensuring peace of mind for families.