New Buck Corporation MODEL 85 INSTALLATION OF CLOSE CLEARANCE SHIELDS, Optional

Page 25
MODEL 85 INSTALLATION OF CLOSE CLEARANCE SHIELDS

MODEL 85 INSTALLATION OF CLOSE CLEARANCE SHIELDS

(Optional)

1.Loosen the three (3) phillips head screws that secure the front cover plates to the front sides of the stove.

2.Take rear close clearance shield and center with back and flushing with the bottom of the stove using the self-tapping screws provided.

2.Remove self-tapping screws from rear of stove. Align holes in side shield with holes in rear shield and attach to stove. NOTE: The rear of the side shields must go over the lip of the rear shield.

3.You must measure one inch (1”) out from the side of the stove to the inside of the shield and main- tain approximately one inch (1”) clearance while securing the shield to the back of the stove with the 10-16x1/2” self tapping screws provided.

4.Before tightening the screws, insert the front end (Lip) of the side shield under the front cover plate on the front side of the stove. Use the same step to install side shield on the op- posite side of the stove.

5.Tighten all screws.

6.Place pipe shield on the back of the rear shield and align the two (2) holes on the parts and secure with the phillips head screws provided.

THREE (3) PHIL-

LIPS HEAD SCREWS (FRONT COVER PLATES)

SIDE SHIELDS

PIPE SHIELD

LIP (Optional)

TWO (2) PILLIPS HEAD SCREWS

REAR SHIELD

FOUR (4) 10-16X1/2” SELF DRILLING SCREWS

NOTE: Use the figure above to install the Close Clearance Shields. Do not use page 23 in the Model 85 In- stallation/Operation Owners Manual.

23

Image 25
Contents Page Page TABLE OF CONTENTS Page MAINTENANCE INSTRUCTIONS MODEL INSTALLATION, OPERATION, ANDREAD THIS FIRST IMPORTANT INSTRUCTIONSINTRODUCTION SECTIONMODEL SECTION MASONRY INSERT INSTALLATIONK* FACTORS OF ALTERNATE MATERIALS MINIMUM CLEARANCESMaterial Required ThicknessINSTALLATION PREPARATION FIREPLACE POSSIBLE TOOLS NEEDED FOR INSTALLATIONMounting the Trim Panels Installation Procedure Positioning the HeaterFinal Check Final Check 5.Check for smoke leaks around the doors SECTION PRE-FABINSERT INSTALLATION PREPARING THE STOVE FOR INSTALLATION SECTION RESIDENTIAL FREE-STANDINGINSTALLATIONMINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL K* FACTORS OF ALTERNATE MATERIALS ALTERNATE FLOOR PROTECTORS MATERIALMaterial Required ThicknessDETERMINING THE CHIMNEY LOCATION ChimneyB.Wall Exit Into Metal Tee-Box C. Wall Exit Into Masonry Using Single Wall Pipe D. Ceiling Exit-CloseClearance ALCOVE INSTALLATION CLEARANCES FINAL CHECK MINIMUM CLEARANCES TO COMBUSTIBLES FREE-STANDING CLEARANCES FOR MODELCLEARANCES FOR MODEL Optional MODEL 85 INSTALLATION OF CLOSE CLEARANCE SHIELDSFOR MINIMUM CLEARANCES SEE PAGE FLOOR PROTECTION FREE-STANDINGMOBILE HOME INSTALLATIONCHIMNEY SECTIONPREPARING THE HEATER FOR INSTALLATION TOOLS FOR INSTALLATIONWARNING DO NOT INSTALL IN A SLEEPING ROOM PREPARING THE ROOM HEATER LOCATION5.Next, remove the four 4 screws holding the heater to the stand. Position heater out of the way of the installation area Ceiling Exit Using Close Clearance Listed Chimney FINAL CHECK SECTION WOOD HEATER SAFETY SECTION OPERATION BUILDING A FIRE ROOM AIR BLOWER OPERATION PROBLEM TROUBLESHOOTINGSOLUTION POSSIBLE CAUSEMODEL WOOD STOVE EPA COMPLIANCE STATUSREPLACEMENT PARTS FOR THE MODEL PROCEDURE WARRANTY TIME PERIODSPRODUCTS COVERED PRODUCTS NOT COVEREDOTHER RIGHTS CONDITIONS AND EXCLUSIONS