SECTION II
MASONRY INSERT INSTALLATION
The Model 81 may be installed using an all masonry fireplace built in accordance with the Uniform Building Code and National Fire Protection Association (NFPA). The first step in this type of installation is to determine the acceptability of the fireplace and chimney for use with a woodstove. Both the construction and condition of the fireplace are important consid- erations when installing a woodstove. It is not necessary to direct connect this unit unless installed in improper drawing fireplace or oversized flue. The chimney should extend at least 3' above the roof and at least 2' above any point of the roof within 10'.
E | F |
| D |
C | B |
|
A
Figure 1
MODEL 85
A. Unit to adjust to Side Wall | 12" |
B. Front Floor Protector | 16" |
C. Side Floor Protector | 8" |
D. Side Wood Trim | 7" |
E. Top Wood Trim | 10" |
F. Mantel or Brackets | 21" |