Heat & Glo LifeStyle ESCAPE-I35-C owner manual What to do if you smell gas

Page 1

Models: ESCAPE-I35-C ESCAPE-I35LP-C ESCAPE-I30-C ESCAPE-I30LP-C

Owner’s Manual

Installation and Operation

NOTICE

DO NOT DISCARD THIS MANUAL

• Important operating

• Read, understand and follow

• Leave this manual with

and maintenance

these instructions for safe

party responsible for use

instructions included.

installation and operation.

and operation.

DO DISCARDNOT

WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury, or death.

DO NOT store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.

What to do if you smell gas

-DO NOT try to light any appliance.

-DO NOT touch any electrical switch. DO NOT use any phone in your building.

-Immediately call your gas supplier from a neighbor’s phone. Follow the gas suppli- er’s instructions.

-If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency, or the gas supplier.

This appliance may be installed as an OEM installation in manufactured home (USA only) or mobile home and must be installed in accordance with the manufacturer’s instructions and the manufactured home construction and safety standard, Title 24 CFR, Part 3280 or Standard for Installation in Mobile Homes, CAN/CSA Z240MH, in Canada.

This appliance is only for use with the type(s) of gas indicated on the rating plate.

WARNING

HOT SURFACES!

Glass and other surfaces are hot during operation AND cool down.

Hot glass will cause burns.

DO NOT touch glass until it is cooled

NEVER allow children to touch glass

Keep children away

CAREFULLY SUPERVISE children in same room as fireplace.

Alert children and adults to hazards of high temperatures.

High temperatures may ignite clothing or other flammable materials.

Keep clothing, furniture, draperies and other flammable materials away.

This appliance has been supplied with an integral barrier to prevent direct contact with the fixed glass panel. DO NOT operate the appliance with the barrier removed.

Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one.

In the Commonwealth of Massachusetts installation must be performed by a licensed plumber or gas fitter.

A CO detector shall be installed in the room where the appliance in installed.

Installation and service of this appliance should be performed by qualified personnel. Hearth & Home Technologies suggests NFI certified or factory trained professionals, or technicians supervised by an NFI certified professional.

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

1

Image 1
Contents Do not Discard this Manual What to do if you smell gasHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Operating Instructions User Guide Gas Fireplace SafetyYour Fireplace Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceControl Module Operation IPI Battery Tray/Battery InstallationNine Hour Safety Shutdown Feature Module Reset SwitchBefore Lighting Fireplace Final inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel Clearance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Vent Limits Installing Vent Pipe and ApplianceVenting Components Connecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Installing Adaptor and Termination CapFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire PlusTM Ignition System Wiring Wiring RequirementsElectrical Information Code CSA C22.1Installation for Fan Optional Optional AccessoriesOrange to Valve Ground to Valve Bracket Green to Valve Programming the RC300 to the Control ModuleFinishing Appliance Setup Placement of Embers Escape-I30-C Ember PlacementLog Set Installed Install the Log AssemblyLOG Hangs Over Onto Burner TOP LOG #6Glass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine Place LOG On Flat Spot LOG #4Air Shutter Settings Air Shutter SettingSymptom Possible Cause Corrective Action TroubleshootingIntelliFire Plus Ignition System Troubleshooting Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsAt Depot FireBrick InsertStocked ESCAPE-I35-C#15 Valve Assembly Service Parts ESCAPE-I30-C, ESCAPE-I35-CESCAPE-I35-C Conversion Kits ESCAPE-I30-C Conversion KitsContact Information