Heat & Glo LifeStyle ESCAPE-I35-C owner manual Lighting Instructions IPI, Final inspection by

Page 11

K. Lighting Instructions (IPI)

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

LIGHTING

INSTRUCTIONS (IPI)

1. This appliance is equipped with an ignition

device which automatically lights the burner.

DO NOT try to light the burner by hand.

A. This appliance is equipped with an intermittent pilot ignition (IPI) device which automatically lights the burn- er. DO NOT try to light the burner by hand.

B.BEFORE LIGHTING, smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

DO NOT try to light any appliance.

DO NOT touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C. DO NOT use this appliance if any part has been under water. Imme- diately call a qualified service tech- nician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

GAS

VALVE

2.

Wait five (5) minutes to clear out any gas.

 

Then smell for gas, including near the floor. If

 

you smell gas, STOP! Follow “B” in the Safety

 

Information located on the left side of this la-

 

bel. If you do not smell gas, go to next step.

3.

To light the burner:

 

Equipped with wall switch: Turn ON/OFF switch

 

to ON.

WARNING:

DO NOT CONNECT LINE VOLT- AGE (110/120 VAC OR 220/240

VAC) TO THE CONTROL VALVE.

Improper installation, adjustment, al- teration, service or maintenance can cause injury or property damage. Re- fer to the owner’s information manual provided with this appliance.

This appliance needs fresh air for safe operation and must be installed so there are provisions for adequate combustion and ventilation air.

If not installed, operated, and main- tained in accordance with the manufac- turer’s instructions, this product could expose you to substances in fuel or fuel combustion which are known to the State of California to cause can- cer, birth defects, or other reproductive harm.

Keep burner and control compartment clean. See installation and operating instructions accompanying appliance.

CAUTION:

Hot while in operation. DO NOT touch. Keep children, clothing, furniture, gaso- line and other liquids having flammable vapors away.

DO NOT operate the appliance with fixed glass assembly removed, cracked or broken. Replacement of the fixed glass assembly should be done by a licensed or qualified service person.

NOT FOR USE

WITH SOLID FUEL

For use with natural gas and propane. A conversion kit, as supplied by the manufacturer, shall be used to convert this appliance to the alternate fuel.

Also Certified for Installation in a Bedroom or a Bedsitting Room.

For assistance or additional informa- tion, consult a qualified installer, ser- vice agency or the gas supplier.

Equipped with remote or wall control: Press

ON or FLAME button.

Equipped with thermostat: Set temperature to

desired setting.

4. If the appliance does not light after three tries,

call your service technician or gas supplier.

TO TURN OFF

GAS TO APPLIANCE

1.Equipped with wall switch: Turn ON/OFF switch to OFF.

Equipped with remote or wall control: Press OFF button.

Equipped with thermostat: Set temperature to lowest setting.

2.Service technician should turn off electric power to the control when performing service.

593-913G

For additional information on operating your

Hearth & Home Technologies fireplace, please refer to www.fireplaces.com.

Final inspection by

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

11

Image 11
Contents Do not Discard this Manual What to do if you smell gasHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalControl Module Operation IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module Reset SwitchNine Hour Safety Shutdown Feature Final inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel Clearance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceVent Limits Connecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Installing Adaptor and Termination CapGas Connection Gas InformationFuel Conversion Gas PressureCode CSA C22.1 Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Electrical InformationInstallation for Fan Optional Optional AccessoriesOrange to Valve Ground to Valve Bracket Green to Valve Programming the RC300 to the Control ModuleFinishing Appliance Setup Placement of Embers Escape-I30-C Ember PlacementLog Set Installed Install the Log AssemblyLOG Hangs Over Onto Burner TOP LOG #6Glass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine Place LOG On Flat Spot LOG #4Air Shutter Settings Air Shutter SettingIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsFireBrick Insert Service PartsLog Set Assembly At DepotStocked ESCAPE-I35-C#15 Valve Assembly Service Parts ESCAPE-I30-C, ESCAPE-I35-CESCAPE-I35-C Conversion Kits ESCAPE-I30-C Conversion KitsContact Information