Heat & Glo LifeStyle ESCAPE-I35-C Fireplace Size Requirements, Minimum Fireplace Opening

Page 18

5 Fireplace Size Requirements

A. Minimum Fireplace Opening

Minimum fireplace opening requirements are shown in Figure 5.2.

WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access.

Due to high temperatures, the appliance should be locat- ed out of traffic and away from furniture and draperies.

The firebrick (refractory), glass doors, screen rails, screen mesh and log grates can be removed from a factory built firebox in order to gain minimum gas insert opening requirements.

Any smoke shelves, shields and baffles may be removed from the factory built firebox if attached with mechanical fasteners.

The metal floor of the solid fuel firebox may be removed to facilitate the installation of the insert.

Cutting of any sheet metal parts of the fireplace in which the gas fireplace insert is to be installed is prohibited, except the floor as tested for and as noted above and in Figure 5.1.

A minimum 1/2 inch gap from the bottom of the appliance to the metal floor of the solid fuel firebox is RECOMMENDED for optimal fan performance. See side view in Figure 5.1.

SIDE VIEW

 

 

TOP VIEW

 

11-1/4

METAL FLOOR OF EXISTING

 

IN.

 

 

 

SOLID FUEL FIREBOX

 

 

 

5 IN.

 

REMOVE THIS

6 IN.

 

SECTION OF

12 IN.

 

METAL FLOOR

 

 

 

 

 

EXISTING FACTORY BUILT FIREBOX

1/2 IN. MINIMUM LEVELING HEIGHT

 

 

 

(RECOMMENDED)

11-1/4

 

ESCAPE-I35-C

1/4 IN. REQUIRED

 

IN.

 

ESCAPE-I30-C

METAL FLOOR OF EXISTING SOLID FUEL FIREBOX

 

 

 

 

 

 

5 IN.

 

REMOVE THIS

 

6 IN.

 

SECTION OF

 

12 IN.

 

METAL FLOOR

 

Figure 5.1-A

Figure 5.1-B

 

 

The appliance may not be placed directly on the base of the outer wrap, a 1/4 inch airspace MUST be provided between the insert and the floor of the outer wrap. Use the levelling legs to raise the insert a minimum of 1/4 inch. The original fireplace may never be returned to solid fuel in this condition. The sidewalls and top structure of the firebox may not be altered with the exception of removable baffles and dampers.

If the recommended 1/2 inch leveling leg height can not be achieved, a section of the factory-built metal floor may be removed. See Figure 5.1-B.

18

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

Image 18
Contents What to do if you smell gas Do not Discard this ManualCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceIPI Battery Tray/Battery Installation Control Module OperationModule Reset Switch Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Lighting Instructions IPI Final inspection byFrequently Asked Questions After Appliance is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel and Wall Projections Mantel ClearanceTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Installing Vent Pipe and Appliance Vent LimitsVenting Components Connecting Vent Pipe Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory BuiltGas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Code CSA C22.1Optional Accessories Installation for Fan OptionalProgramming the RC300 to the Control Module Orange to Valve Ground to Valve Bracket Green to ValveFinishing Appliance Setup Ember Placement Placement of Embers Escape-I30-CInstall the Log Assembly Log Set InstalledLOG #6 LOG Hangs Over Onto Burner TOPGlass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine LOG #4 Place LOG On Flat SpotAir Shutter Setting Air Shutter SettingsTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System Troubleshooting Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsAt Depot Service PartsLog Set Assembly FireBrick InsertESCAPE-I35-C StockedService Parts ESCAPE-I30-C, ESCAPE-I35-C #15 Valve AssemblyESCAPE-I30-C Conversion Kits ESCAPE-I35-C Conversion KitsContact Information