8 Installing Vent Pipe and Appliance
A. Vent Limits
The abbreviations listed in this vent table key are used in the vent diagrams.
Description
Minimum Vertical Run Length 10 ft.
Maximum Vertical Run Length 50 ft.
Horizontal venting is NOT allowed.
Vertical terminations are measured to top of chimney.
This appliance is listed for use with
WARNING! Risk of Fire/Explosion/Asphyxiation! Do NOT connect this gas appliance to a chimney flue serving a separate solid fuel or gas burning appliance.
•May impair safe operation of this appliance or other appliances connected to the flue.
•Vent this appliance directly outside.
•Use separate vent system for this appliance.
CAUTION! ALL vent specifications MUST be followed.
This product is tested and listed to these specifications. Appliance performance will suffer if specifications are not followed.
B. Venting Components
CAUTION! Risk of Cuts/Abrasions/Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.
The vertical vent termination system installed on this model includes:
•One
•Flexible vent pipe for exhaust air (included with vent kit).
•One length of
•One
•One vertical termination cap (included with vent kit).
ADAPTER
V = 10 FT. MINIMUM 50 FT. MAXIMUM
HANDLE
TERMINATION
CAP
INLET
COLLAR
EXHAUST
COLLAR
EXHAUST
AIR
VENT PIPE
INLET AIR
VENT PIPE
INLET AIR STARTING COLLAR
INLET AIR
STARTING
COLLAR
LOCKING TAB
STARTING
COLLAR
BRACKET
EXHAUST
STARTING
COLLAR
NOTE: TO ACHIEVE OPTIMUM PERFORMANCE,
MINIMIZE OR AVOID BENDS IN EXHAUST VENT
PIPE.
STARTING COLLAR BRACKET
EXHAUST STARTING COLLAR
Figure 8.1
Heat & Glo • | 23 |