Heat & Glo LifeStyle ESCAPE-I35-C owner manual Listing and Code Approvals

Page 6

1 Listing and Code Approvals

A. Appliance Certification

MODELS: ESCAPE-I30-C, ESCAPE-I30LP-C, ESCAPE-I35-C, ESCAPE-I35LP-C

LABORATORY: Underwriters Laboratories, Inc. (UL)

TYPE: Vented Gas Appliance Heaters

STANDARD: ANSI Z21.88-2009 • CSA 2.33-2009

This product is listed to ANSI standards for “Vented Gas Appliance Heaters” and applicable sections of “Gas Burn- ing Heating Appliances for Manufactured Homes and Recreational Vehicles”, and “Gas Fired Appliances for Use at High Altitudes”.

Heat & Glo gas inserts are designed for installations into solid fuel masonry or factory built fireplaces that have been installed in accordance with the National, Provincial, State and local building codes. Fireplaces are to be constructed of non-combustible materials and, in the absence of local or regional codes, meet criteria of NFPA 211. No additional outside air source is required.

NOTICE: This installation must conform with local codes. In the absence of local codes you must comply with the National Fuel Gas Code, ANSI Z223.1-latest edition in the U.S.A. and the CAN/CGA B149 Installation Codes in Canada.

NOT INTENDED FOR USE AS A PRIMARY HEAT SOURCE.

This appliance is tested and approved as either supplemen- tal room heat or as a decorative appliance. It should not be factored as primary heat in residential heating calculations.

B. Glass Specifications

This appliance is equipped with 5 mm ceramic glass. Re- place glass only with 5 mm ceramic glass. Please contact your dealer for replacement glass.

D. High Altitude Installations

NOTICE: If the heating value of the gas has been reduced, these rules do not apply. Check with your local gas utility or authorities having jurisdiction.

When installing above 2000 feet elevation:

In the USA: Reduce input rate 4% for each 1000 feet above 2000 feet.

In CANADA: Reduce input rate 10% for elevations between 2000 feet and 4500 feet. Above 4500 feet, consult local gas utility.

Check with your local gas utility to determine proper orifice size.

E. Non-Combustible Materials Specification

Material which will not ignite and burn. Such materials are those consisting entirely of steel, iron, brick, tile, concrete, slate, glass or plasters, or any combination thereof.

Materials that are reported as passing ASTM E 136,

Standard Test Method for Behavior of Materials in a Vertical Tube Furnace at 750 ºC and UL763 shall be considered non-combustible materials.

F. Combustible Materials Specification

Materials made of or surfaced with wood, compressed pa- per, plant fibers, plastics, or other material that can ignite and burn, whether flame proofed or not, or plastered or unplastered shall be considered combustible materials.

G. Electrical Codes

NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code CSA

C22.1.

C. BTU Specifications

Models

 

Maximum

Minimum

Orifice

 

Input

Input

Size

(U.S. or Canada)

 

BTU/h

BTU/h

(DMS)

ESCAPE-I30-C

 

US

36,000

17,000

33

 

(0-2000 FT)

 

 

 

 

(NG)

 

CANADA

33,250

16,750

34

 

(2000-4500 FT)

ESCAPE-I30LP-C

 

US

36,000

19,000

50

 

(0-2000 FT)

 

 

 

 

(LP)

 

CANADA

31,000

15,500

51

 

(2000-4500 FT)

Escape-I35-C

 

US

40,000

20,000

31

 

(0-2000 FT)

 

 

 

 

(NG)

 

CANADA

37,000

19,250

32

 

(2000-4500 FT)

ESCAPE-I35LP-C

 

US

38,000

19,000

49

 

(0-2000 FT)

 

 

 

 

(LP)

 

CANADA

35,000

17,000

50

 

(2000-4500 FT)

A 120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks.

6

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

Image 6
Contents What to do if you smell gas Do not Discard this ManualCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Gas Fireplace Safety Operating Instructions User GuideYour Fireplace Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceIPI Battery Tray/Battery Installation Control Module OperationModule Reset Switch Nine Hour Safety Shutdown FeatureBefore Lighting Fireplace Lighting Instructions IPI Final inspection byFrequently Asked Questions After Appliance is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemDesign and Installation Considerations Tools and Supplies NeededInspect Appliance and Components Fireplace Size Requirements Minimum Fireplace OpeningMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel and Wall Projections Mantel ClearanceTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Installing Vent Pipe and Appliance Vent LimitsVenting Components Connecting Vent Pipe Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory BuiltGas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Code CSA C22.1Optional Accessories Installation for Fan OptionalProgramming the RC300 to the Control Module Orange to Valve Ground to Valve Bracket Green to ValveFinishing Appliance Setup Ember Placement Placement of Embers Escape-I30-CInstall the Log Assembly Log Set InstalledLOG #6 LOG Hangs Over Onto Burner TOPGlass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine LOG #4 Place LOG On Flat SpotAir Shutter Setting Air Shutter SettingsTroubleshooting Symptom Possible Cause Corrective ActionIntelliFire Plus Ignition System Troubleshooting Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsAt Depot Service PartsLog Set Assembly FireBrick InsertESCAPE-I35-C StockedService Parts ESCAPE-I30-C, ESCAPE-I35-C #15 Valve AssemblyESCAPE-I30-C Conversion Kits ESCAPE-I35-C Conversion KitsContact Information