C. IPI Battery Tray/Battery Installation
The IntelliFire PlusTM system has a battery backup option. Batteries should only be placed in the battery pack when 120VAC is not available. See Section 2.H.
D. Control Module Operation
See Section 2.I for control module operation instructions.
E. Optional Accessories
To connect optional accessories, the supplied cord as- sembly should be used. See Figures 10.2 and 10.3 for optional accessories.
WARNING! Risk of Shock! Label all wires prior to dis- connection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with type 105° C rated wire. Wire must have high temperature insulation.
F. Installation for Fan (Optional)
On appliances already installed, removal of decorative front surround and gas insert is required.
1.Remove appliance from wall.
2.Disconnect power by shutting off circuit breaker or unplugging appliance power cord from its receptacle.
3.Remove access panel from lower rear of the fireplace insert. See Figure 10.2.
4.Secure to support base with two screws.
5.Connect black, white, and green wires from blower wire assembly to each blower. See Figure 10.3.
6.Insert plug from blower cable assembly into AUX300 receptacle. See Figure 10.3.
7.Bundle and zip tie loose wires to keep them from con- tacting blower impeller blades
8.Position the right and left blower assembly into the rear opening. Take care to ensure that blower housing or its motor is clear of any adjacent metal. This will ensure that no undue noise occurs during blower operation. See Figure 10.3.
FAN |
ACCESS PANEL |
POWER CORD |
Figure 10.2 |
Heat & Glo • | 29 |