7 Installation Preparation
Prepare the existing solid fuel masonry or factory built
A. Inspection and Cleaning
Prior to installing the gas insert:
•Have the chimney and adjacent structure inspected and cleaned by qualified professionals. Hearth & Home Technologies recommends that NFI or CSIA certified professionals, or technicians under the direction of certi- fied professionals, conduct a minimum of a NFPA 211 Level 2 inspection of the chimney.
•Replace component parts of the chimney and fireplace as specified by the professionals.
•Ensure all joints are properly engaged and the chimney is properly secured.
•Ensure combustible mantel and surround clearances comply with applicable codes and regulations for solid- fuel fireplaces. In the absence of local or regional codes, refer to NFPA 211.
•Ensure chimney is constructed of
•Ensure chimney is clean and in good working order.
•Ensure that all chimney cleanouts fit properly to prevent air leakage into chimney.
B. Flue Damper
Fully lock the solid fuel fireplace’s flue damper in the open position, OR completely remove it.
C. Gas Line
Note: If the factory built fireplace has no gas access hole provided, an access hole of 1 inch (25 mm) diameter or less may be drilled through the lower sides or bottom of the firebox in a proper workmanship - like manner. This access hole must be plugged with
•Install gas line into firebox cavity.
•Check local codes and gas line sizing requirements following NFPA51. See Section 9.
D. Fireplace Conversion Notice
Permanently attach the label with the following warning to the inside lower back of the fireplace firebox into which the insert is being installed. Silicone or mechanical fasteners may be required to properly secure the label.
WARNING! Risk of Fire! This fireplace has been con- verted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all original parts have been replaced, and the fireplace
E. Electrical Outlet Box
An outlet box may be installed in a bottom back corner of the existing solid fuel masonry or factory built fireplace to permit blowers or other optional accessories to be used. Alternatively, the supplied power cord may be routed out onto the hearth to a nearby outlet.
F. Remote Control Configuration
The Intellifire PlusTM should be programmed to the RC300 remote control prior to the installation of the insert into the existing solid fuel masonry or factory built fireplace.
The control is accessed by removing the lower access panel on the left side of the insert. See Section 10.E for details.
22 | Heat & Glo • |