Heat & Glo LifeStyle ESCAPE-I35-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine

Page 38

FLAT SPOT FOR LOG#6

1

LOG MATES WITH CORNER OF BURNER

2

LOG HANGS OVER

ONTO BURNER TOP

Figure 4. Log #2

Log #2 (SRV2202-701): See Figure 2 for additional references. Position Log #2 as shown in Figure 4. Mate Log #2 with the right corner of the burner as shown. Pull the log forward and to the left until it locks into position.

LOG CONTACTS LEFT GRATE TINE

3

LOG CONTACTS RIGHT GRATE TINE

4

Figure 5. Log #3

Figure 6. Log #4

Log #3 (SRV2202-704): See Figure 2 for additional reference details. Locate the log slot on the bottom right end of Log #3. Mate the log slot with the left log pin. Rotate the left end of the log counterclockwise, until it contacts the grate tine. Log #4 (SRV2202-703): See Figure 2 for additional reference details. Locate the log slot on the bottom left end of log #4. Mate the log slot with the right log pin. Rotate the right end of the log clockwise, until it contacts the grate tine.

GLASS ROCK

Figure 7. Glass Rock in Place

Glass Rock (2201-853):Once Log #3 and Log #4 are installed, fill each light tray with the glass rock.

WARNING! Risk of Explosion! DO NOT place glass rock on the burner surface. DO NOT place glass rock directly over burner ports. Improperly placed glass rock interferes with proper burner operation.

38

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

Image 38
Contents What to do if you smell gas Do not Discard this ManualCongratulations Homeowner Reference InformationTable of Contents User GuideLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Fan Kit optional Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Clear SpaceIPI Battery Tray/Battery Installation Control Module OperationBefore Lighting Fireplace Module Reset SwitchNine Hour Safety Shutdown Feature Lighting Instructions IPI Final inspection byFrequently Asked Questions After Appliance is LitGlass Cleaning Maintenance and ServiceMaintenance Tasks-Homeowner Remote ControlVenting Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Fireplace Size Requirements Minimum Fireplace OpeningMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel and Wall Projections Mantel ClearanceTermination Locations Vent Termination Minimum ClearancesInstallation Preparation Venting Components Installing Vent Pipe and ApplianceVent Limits Connecting Vent Pipe Placing, Securing and Leveling the Appliance Installing Adaptor and Termination Cap Factory BuiltGas Pressure Gas InformationFuel Conversion Gas ConnectionElectrical Information Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Code CSA C22.1Optional Accessories Installation for Fan OptionalProgramming the RC300 to the Control Module Orange to Valve Ground to Valve Bracket Green to ValveFinishing Appliance Setup Ember Placement Placement of Embers Escape-I30-CInstall the Log Assembly Log Set InstalledLOG #6 LOG Hangs Over Onto Burner TOPGlass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine LOG #4 Place LOG On Flat SpotAir Shutter Setting Air Shutter SettingsIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Appliance Dimension Diagram Reference MaterialsVent Kits Components Direct Vent Flex Liner KitsAt Depot Service PartsLog Set Assembly FireBrick InsertESCAPE-I35-C StockedService Parts ESCAPE-I30-C, ESCAPE-I35-C #15 Valve AssemblyESCAPE-I30-C Conversion Kits ESCAPE-I35-C Conversion KitsContact Information