Heat & Glo LifeStyle ESCAPE-I35-C owner manual LOG #6, LOG Hangs Over Onto Burner TOP

Page 35

FLAT SPOT FOR

LOG #6

1 2

LOG HANGS OVER

ONTO BURNER TOP

Figure 4. Log #2

Log #2 (SRV2201-701): See Figure 2 for additional references. Position Log #2 as shown in Figure 4. Mate Log #2 with the right corner of the burner as shown. Pull the log forward and to the left until it locks into position.

LOG CONTACTS LEFT GRATE TINE

3

Figure 5. Log #3

LOG CONTACTS RIGHT

GRATE TINE

LOG CONTACTS4 RIGHT

4 GRATE TINE

Figure 6. Log #4

Log #3 (SRV2201-704): See Figure 2 for additional details. Locate the log slot on the bottom right end of Log #3. Mate the log slot with the left log pin. Rotate the left end of the log counterclockwise, until it contacts the grate tine.

Log #4 (SRV2201-705): See Figure 2 for additional details. Locate the log slot on the bottom left end of log #4. Mate the log slot with the right log pin. Rotate the right end of the log clockwise, until it contacts the grate tine.

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

35

Image 35
Contents Do not Discard this Manual What to do if you smell gasHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyRemote Controls, Wall Controls and Wall Switches Fan Kit optionalControl Module Operation IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module Reset SwitchNine Hour Safety Shutdown Feature Final inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsRemote Control Maintenance and ServiceMaintenance Tasks-Homeowner Glass CleaningLogs Maintenance Tasks-Service TechnicianGasket Seal and Glass Assembly Inspection VentingIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel Clearance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceVent Limits Connecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Installing Adaptor and Termination CapGas Connection Gas InformationFuel Conversion Gas PressureCode CSA C22.1 Wiring RequirementsIntelliFire PlusTM Ignition System Wiring Electrical InformationInstallation for Fan Optional Optional AccessoriesOrange to Valve Ground to Valve Bracket Green to Valve Programming the RC300 to the Control ModuleFinishing Appliance Setup Placement of Embers Escape-I30-C Ember PlacementLog Set Installed Install the Log AssemblyLOG Hangs Over Onto Burner TOP LOG #6Glass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine Place LOG On Flat Spot LOG #4Air Shutter Settings Air Shutter SettingIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsFireBrick Insert Service PartsLog Set Assembly At DepotStocked ESCAPE-I35-C#15 Valve Assembly Service Parts ESCAPE-I30-C, ESCAPE-I35-CESCAPE-I35-C Conversion Kits ESCAPE-I30-C Conversion KitsContact Information