13 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified technician in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified technician. Contact your dealer to arrange a service call by a qualified technician.

A. IntelliFire Plus™ Ignition System

Symptom

Possible Cause

Corrective Action

 

 

 

1. Pilot won’t light.

A. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor are

The ignitor/module

 

connected to correct terminals on module and pilot assembly.

makes noise, but no

 

 

B. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from mod-

spark.

 

shorts in the wiring.

ule to pilot assembly. Verify connections underneath pilot assembly

 

 

are tight; also verify igniter and flame sense wires are not grounding

 

 

out to metal chassis, pilot burner, pilot enclosure, mesh screen if

 

 

present, or any other metal object.

 

 

 

 

C. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 in. or 1/8 in. (3 mm).

 

 

 

2. Pilot won’t light,

A. No power, transformer installed

Verify that transformer is installed and plugged into module. Check

there is no noise or

incorrectly, or depleted batteries.

voltage of transformer at connection to module. Acceptable read-

spark.

 

ings of a good transformer are between 6.4 and 6.6 volts AC. Bat-

 

 

tery power supply voltage must be at least 4 volts. If below 4 volts,

 

 

replace batteries.

 

 

 

 

B. A shorted or loose connection in

Remove and reinstall the wiring harness that plugs into module.

 

wiring configuration or wiring har-

Verify there is a tight fit. Verify pilot assembly wiring to module. Re-

 

ness.

move and verify continuity of each wire in wiring harness. Replace

 

 

any damaged components.

 

 

 

 

C. Improper wall switch wiring.

Verify that 120/VAC power is “ON” to junction box.

 

 

 

 

D. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

 

 

3. Pilot sparks, but

A. Gas supply.

Verify that incoming gas line ball valve is “open”. Verify that inlet

Pilot will not light.

 

pressure reading is within acceptable limits.

 

 

 

 

B. Ignitor gap is too large.

Verify gap of igniter to right side of pilot hood. The gap should be

 

 

approximately .17 in. or 1/8 in. (3 mm).

 

 

 

 

C. Module is not grounded.

Verify module is securely grounded to metal chassis of appliance.

 

 

 

 

D. Pilot valve solenoid

Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module.

 

 

If below 1.5 volts, replace module. If 1.5 volts or greater, replace

 

 

valve.

 

 

 

Heat & Glo • Escape-I35-C, Escape-I30-C2201-901 Rev. H • 5/12

41

Image 41
Contents Do not Discard this Manual What to do if you smell gasHomeowner Reference Information CongratulationsUser Guide Table of ContentsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Your Fireplace Gas Fireplace SafetyOperating Instructions User Guide Remote Controls, Wall Controls and Wall Switches Fixed Glass AssemblyFan Kit optional Clear SpaceControl Module Operation IPI Battery Tray/Battery InstallationBefore Lighting Fireplace Module Reset SwitchNine Hour Safety Shutdown Feature Final inspection by Lighting Instructions IPIAfter Appliance is Lit Frequently Asked QuestionsMaintenance Tasks-Homeowner Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection Maintenance Tasks-Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Minimum Fireplace Opening Fireplace Size RequirementsMinimum Fireplace Size ESCAPE-I35-C ESCAPE-I30-C Mantel Clearance Mantel and Wall ProjectionsVent Termination Minimum Clearances Termination LocationsInstallation Preparation Venting Components Installing Vent Pipe and ApplianceVent Limits Connecting Vent Pipe Placing, Securing and Leveling the Appliance Factory Built Installing Adaptor and Termination CapFuel Conversion Gas InformationGas Pressure Gas ConnectionIntelliFire PlusTM Ignition System Wiring Wiring RequirementsElectrical Information Code CSA C22.1Installation for Fan Optional Optional AccessoriesOrange to Valve Ground to Valve Bracket Green to Valve Programming the RC300 to the Control ModuleFinishing Appliance Setup Placement of Embers Escape-I30-C Ember PlacementLog Set Installed Install the Log AssemblyLOG Hangs Over Onto Burner TOP LOG #6Glass Rock ESCAPE-I35-C, ESCAPE-I35LP-C LOG Contacts Left Grate Tine LOG Contacts Right Grate Tine Place LOG On Flat Spot LOG #4Air Shutter Settings Air Shutter SettingIntelliFire Plus Ignition System TroubleshootingSymptom Possible Cause Corrective Action Troubleshooting Reference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLog Set Assembly Service PartsAt Depot FireBrick InsertStocked ESCAPE-I35-C#15 Valve Assembly Service Parts ESCAPE-I30-C, ESCAPE-I35-CESCAPE-I35-C Conversion Kits ESCAPE-I30-C Conversion KitsContact Information