B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear- ances to combustibles as specified. Framing closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc.) Failure to comply could cause fire.
Note: For
Mantels (Combustible/Non-Combustible)
3/8 in. (10 mm) |
|
Thick Wall |
|
Sheathing | |
| MAX. |
MEASUREMENT
14 in. FROM TOP OF
(360 mm) FIREPLACE MIN. OPENING
Figure 13.7 Clearances To Combustible Mantels Or Other
Combustibles Above Appliance
Note: For
Mantel Leg (Combustible/Non-Combustible)
TOP VIEW |
|
3 in. | UNLIMITED |
(80 mm) | |
MIN. |
|
7 in. |
|
(180 mm) |
|
Figure 13.8 | |
Projections |
|
(Acceptable on both sides of opening) |
Front Side Finishing Detail
| |
| FRAMING |
| |
| 3/8 in. (10 mm) BUILDING MATERIAL |
Figure 13.9 | Front Side Finishing Detail |
Heat & Glo • | 49 |