Heat & Glo LifeStyle SLR-C (COSMO) A. Congratulations, Homeowner Reference Information

Page 2
A. Congratulations
NATURAL GAS

Read this manual before installing or operating this appliance.

Please retain this owner’s manual for future reference.

A. Congratulations

Congratulations on selecting a Heat & Glo gas fireplace, an elegant and clean alternative to wood burning fireplaces. The Heat & Glo gas fireplace you have selected is designed to provide the utmost in safety, reliability, and efficiency.

As the owner of a new fireplace, you’ll want to read and carefully follow all of the instructions contained in this owner’s manual. Pay special attention to all cautions and warnings.

This owner’s manual should be retained for future reference. We suggest that you keep it with your other important documents and product manuals.

The information contained in this owner’s manual, unless noted otherwise, applies to all models and gas control systems.

Your new Heat & Glo gas fireplace will give you years of durable use and trouble-free enjoyment. Welcome to the Heat & Glo family of fireplace products!

Homeowner Reference Information

We recommend that you record the following pertinent information about your fireplace.

Model Name: ___________________________________________ Date purchased/installed:__________________

Serial Number:__________________________________________ Location on fireplace: _____________________

Dealership purchased from: _______________________________ Dealer Phone: __________________________

Notes: _______________________________________________________________________________________

_____________________________________________________________________________________________

Listing Label Information/Location The model information regarding your specific fireplace can be found on the rating plate usually located in the control area of the fireplace.

Type of Gas

Gas and Electric Information

Heat & Glo, a brand of Hearth & Home Technologies, Inc. 7571 215th Street West, Lakeville, MN 55044

Not for use with solid fuel.

(Ne doit pas entre utilise avec un combustible solide).

Type of Gas (Sorte De Gaz): This appliance must be installed in accordance with local codes, if any; if not, follow ANSI Z223.1 in the USA or CAN/CGA B149 installation codes. (Installer l’appareil selon les codes ou reglements locaux ou, en l’absence de tels reglements, selon les codes d’installation CAN/CGA-B149.)

ANSI Z21XX-XXXX · CSA 2.XX-MXX · UL307B

Minimum Permissible Gas Supply for Purposes of Input Adjustment.

 

 

 

Approved Minimum (De Gaz) Acceptable

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Maximum Pressure (Pression)

 

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Maximum Manifold Pressure (Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Minimum Manifold Pressure (Pression)

0.0 in w.c.

(Po. Col. d’eau)

 

 

 

Total Electrical Requirements: 000Vac, 00Hz., less than 00 Amperes

MADE IN USA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IN CANADA

 

Model:

XXXXXXXX

 

ALTITUDE:

0-0000 FT.

0000-0000FT.

 

(Modele):

 

MAX. INPUT BTUH:

00,000

00,000

 

 

 

 

 

 

 

MIN. INPUT BTUH:

00,000

00,000

 

Serial

XXXXXXXX

 

ORIFICE SIZE:

#XXXXX

#XXXXX

 

 

 

(Serie):

 

Model Number

Serial Number

2

Heat & Glo • SLR-C2292-900 Rev. D • 8/12

Image 2
Contents •What to do if you smell gas NOTICEModel SLR-CCOSMO Owner’s ManualA. Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsSafety Alert Key User Guide = Contains updated information 14 Appliance Setup15 Troubleshooting 13 FinishingWARRANTY COVERAGE B. Limited Lifetime WarrantyLIMITED LIFETIME WARRANTY WARRANTY PERIODWARRANTY EXCLUSIONS B. Limited Lifetime Warranty continuedWARRANTY CONDITIONS This warranty is void ifA. Appliance Certification D. High Altitude Installations1 Listing and Code Approvals B. Tempered Glass SpecificationsInstallation of Carbon Monoxide Detectors B. Your Fireplace A. Gas Fireplace Safety2 Operating Instructions User Guide WARNING! Choking Hazard! Keep glass rock mediaD. Decorative Doors and Fronts E. Fixed Glass AssemblyC. Clear Space G. Before Lighting FireplaceFOR YOUR SAFETY READ BEFORE LIGHTING H. Lighting Instructions IPIFinal inspection by LIGHTING INSTRUCTIONS IPIInitial Break-inProcedure J. Frequently Asked QuestionsI. After Fireplace is Lit •Some people may be sensitive to smoke and odorsGlass Cleaning 3 Maintenance and ServiceA. Maintenance Tasks-Homeowner Remote ControlFirebox B.Maintenance Tasks-QualifiedService TechnicianGasket Seal and Glass Assembly Inspection Control Compartment and Firebox TopInstaller Guide Getting StartedA. Typical Appliance System WALL SWITCHD. Inspect Appliance and Components B. Design and Installation ConsiderationsC. Tools and Supplies Needed 5 Framing and Clearances A. Selecting Appliance LocationB. Constructing the Appliance Chase Heat & Glo • SLR-C• 2292-900Rev. D • 8/12C. Clearances MINIMUM FRAMING DIMENSIONSD. Mantel and Wall Projections 3-1/2IN Figure 5.8 Non-CombustibleZoneHeat & Glo • SLR-C• 2292-900Rev. D • 8/12 6 Termination Locations A. Vent Termination Minimum ClearancesV= VENT TERMINAL X = AIR SUPPLY INLET = AREA WHERE TERMINAL IS NOT PERMITTEDCovered Alcove Applications A. Approved Pipe 7 Vent Information and DiagramsE. Vent Diagrams B. Vent Table KeyTop Vent - Horizontal Termination Venting with 1 elbowINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedVenting with 2 elbows Top Vent - Horizontal TerminationTop Vent - Horizontal Termination Venting with 3 elbows1. Top Vent - Horizontal Termination - continued SLR-CH2 H1 V1 INSTALLED HORIZONTALLYINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedExhaust restrictor Instructions Top Vent - Vertical Termination No ElbowsV1 = 44 ft. Max. 13.4 m PILOT HOLESSLR-C Top Vent - Vertical TerminationVenting with 2 elbows V1 MinimumSLR-C Top Vent - Vertical TerminationVenting with 3 elbows V1 MinimumV3 H2 H1 V1 Venting with 4 elbowsTop Vent - Vertical Termination V1 MINTable Coaxial to Colinear VentingPrior to installing the gas appliance Clearances to Combustibles•Use separate vent system for this appliance TOP VENT•Vent this appliance directly outside B. Wall Penetration Framing 8 Vent Clearances and FramingA. Pipe Clearances to Combustibles •Between ceiling firestopsC. Install the Ceiling Firestop Vaulted Ceiling Installation D. Install Attic Insulation ShieldFlat Ceiling Installation 9 Appliance Preparation A. Top Vent•Sagging or loose insulation B. Securing and Leveling the ApplianceWARNING! Risk of Fire! Prevent contact with •Insulation backing or plastic10 Installing Vent Pipe SLP Pipe A. Assemble Vent SectionsPilot hole B. Assemble Slip SectionsC. Secure The Vent Sections E. Install Decorative Ceiling Components D. Disassemble Vent SectionsCAULK F. Install Metal Roof FlashingG. Assemble and Install Storm Collar Figure H. Install Vertical Termination CapI. Install Decorative Wall Components Figure 10.16 Wall ThimbleK. Install Horizontal Termination Cap Figure 10.17 Venting through the wallB. Gas Pressure 11 Gas InformationA. Fuel Conversion Valve Pressure Taps C. Gas ConnectionD. High Altitude Installations Ensure adequate ventilationC. Optional Accessories Requirements A. Wiring RequirementsB. IntelliFire Ignition System Wiring 12 Electrical InformationD. Electrical Service and Repair E. Junction Box InstallationDrywall gypsum board Plywood 13 FinishingA. Framing and Finishing Instructions NON-COMBUSTIBLEBOARD Figure 13.3 Finishing DetailsFinish and Sealing Joints FIREPLACE OPENING15-7/8IN. TO 16-1/8IN Finishing Around Opening with Gypsum WallboardB. Mantel and Wall Projections 0 - 1 inch thickness-OverlapFit Method C. Facing MaterialNon-CombustibleFinish Materials Non-CombustibleFinish Material 0-4Inches Thick Non-CombustibleFinish Materials0 Inches to 4 Inches Thick Inside Fit Method 3/4 INTable 1. Dimensions of Tonic Decorative Front D. Decorative FrontsTable 1. Dimensions of Tonic Decorative Front Inside and Overlap Fit See Section 13.CC. Clean the Appliance 14 Appliance SetupA. Remove Fixed Glass Assembly D. AccessoriesFigure 14.4. Maintaining Media Tray Air Spaces PILOT SHIELD BURNER TRACKSNO GLASS ROCK MEDIA BETWEEN DASHED LINES H. Air Shutter Setting F. Fixed Glass AssemblyG. Install the Mesh Removing Fixed Glass Assembly15 Troubleshooting A. IntelliFire Ignition SystemIntelliFire Ignition System - continued Location A. Appliance Dimension Diagram16 Reference Materials Inches6-1/2in B. Vent Components DiagramsEffective Height Length 165 mm3-15/16in B. Vent Components Diagrams continued6-11/16in 169 mm7 IN 178 mm B. Vent Components Diagrams continued15-1/2IN 394 mm 12IN 305mmOptional Wire Harness COAXIAL to COLINEAR VENTINGB. Vent Components Diagrams continued DESCRIPTION12-1/2in B. Vent Components Diagrams9 in 2-3/4inSLR-CCOSMO Service PartsC. Service Parts StockedSLR-CCOSMO Service Parts#11 Valve Assembly at Depotat Depot Service PartsSLR-CCOSMO StockedNOTICE D. Contact InformationNOTES