Heat & Glo LifeStyle SLR-C (COSMO) owner manual Pilot Shield Burner Tracks

Page 58
PILOT SHIELD

PILOT SHIELD

BURNER

TRACKS

Figure 14.3. Placing Glass Rock Media on Pilot Shield

WARNING! Risk of Fire! DO NOT place glass rock me- dia directly in front of the pilot assembly or between the burner tracks over the burner ports.

NOTICE: Care should be taken to avoid placing glass rock media between the left, right and back edges of the media tray and the firebox. Blocking this gap may cause an undesirable flame appearance. See Figure 14.4.

NO GLASS ROCK MEDIA BETWEEN DASHED LINES.

Figure 14.4. Maintaining Media Tray Air Spaces.

58

Heat & Glo • SLR-C2292-900 Rev. D • 8/12

Image 58
Contents •What to do if you smell gas NOTICEModel SLR-CCOSMO Owner’s ManualA. Congratulations Homeowner Reference InformationInstaller Guide Table of ContentsSafety Alert Key User Guide = Contains updated information 14 Appliance Setup15 Troubleshooting 13 FinishingWARRANTY COVERAGE B. Limited Lifetime WarrantyLIMITED LIFETIME WARRANTY WARRANTY PERIODWARRANTY EXCLUSIONS B. Limited Lifetime Warranty continuedWARRANTY CONDITIONS This warranty is void ifA. Appliance Certification D. High Altitude Installations1 Listing and Code Approvals B. Tempered Glass SpecificationsInstallation of Carbon Monoxide Detectors B. Your Fireplace A. Gas Fireplace Safety2 Operating Instructions User Guide WARNING! Choking Hazard! Keep glass rock mediaD. Decorative Doors and Fronts E. Fixed Glass AssemblyC. Clear Space G. Before Lighting FireplaceFOR YOUR SAFETY READ BEFORE LIGHTING H. Lighting Instructions IPIFinal inspection by LIGHTING INSTRUCTIONS IPIInitial Break-inProcedure J. Frequently Asked QuestionsI. After Fireplace is Lit •Some people may be sensitive to smoke and odorsGlass Cleaning 3 Maintenance and ServiceA. Maintenance Tasks-Homeowner Remote ControlFirebox B.Maintenance Tasks-QualifiedService TechnicianGasket Seal and Glass Assembly Inspection Control Compartment and Firebox TopInstaller Guide Getting StartedA. Typical Appliance System WALL SWITCHC. Tools and Supplies Needed B. Design and Installation ConsiderationsD. Inspect Appliance and Components 5 Framing and Clearances A. Selecting Appliance LocationB. Constructing the Appliance Chase Heat & Glo • SLR-C• 2292-900Rev. D • 8/12C. Clearances MINIMUM FRAMING DIMENSIONSD. Mantel and Wall Projections Heat & Glo • SLR-C• 2292-900Rev. D • 8/12 Figure 5.8 Non-CombustibleZone3-1/2IN 6 Termination Locations A. Vent Termination Minimum ClearancesCovered Alcove Applications = AREA WHERE TERMINAL IS NOT PERMITTEDV= VENT TERMINAL X = AIR SUPPLY INLET A. Approved Pipe 7 Vent Information and DiagramsE. Vent Diagrams B. Vent Table KeyTop Vent - Horizontal Termination Venting with 1 elbowINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedVenting with 2 elbows Top Vent - Horizontal TerminationTop Vent - Horizontal Termination Venting with 3 elbows1. Top Vent - Horizontal Termination - continued SLR-CH2 H1 V1 INSTALLED HORIZONTALLYINSTALLED HORIZONTALLY 1. Top Vent - Horizontal Termination - continuedExhaust restrictor Instructions Top Vent - Vertical Termination No ElbowsV1 = 44 ft. Max. 13.4 m PILOT HOLESSLR-C Top Vent - Vertical TerminationVenting with 2 elbows V1 MinimumSLR-C Top Vent - Vertical TerminationVenting with 3 elbows V1 MinimumV3 H2 H1 V1 Venting with 4 elbowsTop Vent - Vertical Termination V1 MINTable Coaxial to Colinear VentingPrior to installing the gas appliance Clearances to Combustibles•Vent this appliance directly outside TOP VENT•Use separate vent system for this appliance B. Wall Penetration Framing 8 Vent Clearances and FramingA. Pipe Clearances to Combustibles •Between ceiling firestopsC. Install the Ceiling Firestop Flat Ceiling Installation D. Install Attic Insulation ShieldVaulted Ceiling Installation 9 Appliance Preparation A. Top Vent•Sagging or loose insulation B. Securing and Leveling the ApplianceWARNING! Risk of Fire! Prevent contact with •Insulation backing or plastic10 Installing Vent Pipe SLP Pipe A. Assemble Vent SectionsC. Secure The Vent Sections B. Assemble Slip SectionsPilot hole E. Install Decorative Ceiling Components D. Disassemble Vent SectionsG. Assemble and Install Storm Collar F. Install Metal Roof FlashingCAULK Figure H. Install Vertical Termination CapI. Install Decorative Wall Components Figure 10.16 Wall ThimbleK. Install Horizontal Termination Cap Figure 10.17 Venting through the wallA. Fuel Conversion 11 Gas InformationB. Gas Pressure Valve Pressure Taps C. Gas ConnectionD. High Altitude Installations Ensure adequate ventilationC. Optional Accessories Requirements A. Wiring RequirementsB. IntelliFire Ignition System Wiring 12 Electrical InformationD. Electrical Service and Repair E. Junction Box InstallationA. Framing and Finishing Instructions 13 FinishingDrywall gypsum board Plywood NON-COMBUSTIBLEBOARD Figure 13.3 Finishing DetailsFinish and Sealing Joints FIREPLACE OPENING15-7/8IN. TO 16-1/8IN Finishing Around Opening with Gypsum WallboardB. Mantel and Wall Projections Non-CombustibleFinish Materials C. Facing Material0 - 1 inch thickness-OverlapFit Method Non-CombustibleFinish Material 0-4Inches Thick Non-CombustibleFinish Materials0 Inches to 4 Inches Thick Inside Fit Method 3/4 INTable 1. Dimensions of Tonic Decorative Front D. Decorative FrontsTable 1. Dimensions of Tonic Decorative Front Inside and Overlap Fit See Section 13.CC. Clean the Appliance 14 Appliance SetupA. Remove Fixed Glass Assembly D. AccessoriesNO GLASS ROCK MEDIA BETWEEN DASHED LINES PILOT SHIELD BURNER TRACKSFigure 14.4. Maintaining Media Tray Air Spaces H. Air Shutter Setting F. Fixed Glass AssemblyG. Install the Mesh Removing Fixed Glass Assembly15 Troubleshooting A. IntelliFire Ignition SystemIntelliFire Ignition System - continued Location A. Appliance Dimension Diagram16 Reference Materials Inches6-1/2in B. Vent Components DiagramsEffective Height Length 165 mm3-15/16in B. Vent Components Diagrams continued6-11/16in 169 mm7 IN 178 mm B. Vent Components Diagrams continued15-1/2IN 394 mm 12IN 305mmOptional Wire Harness COAXIAL to COLINEAR VENTINGB. Vent Components Diagrams continued DESCRIPTION12-1/2in B. Vent Components Diagrams9 in 2-3/4inSLR-CCOSMO Service PartsC. Service Parts StockedSLR-CCOSMO Service Parts#11 Valve Assembly at Depotat Depot Service PartsSLR-CCOSMO StockedNOTES D. Contact InformationNOTICE