Heat & Glo LifeStyle SLR-C (COSMO) owner manual Appliance Setup, A. Remove Fixed Glass Assembly

Page 57
14 Appliance Setup

14 Appliance Setup

A. Remove Fixed Glass Assembly

See Section 14.F.

B. Remove the Shipping Materials

Remove shipping materials from inside or underneath the firebox. The standard black rock media and manual bag assembly are also shipped underneath the firebox.

C. Clean the Appliance

Clean/vacuum any sawdust that may have accumulated inside the firebox or underneath in the control cavity.

D. Accessories

Install approved accessories per instructions included with accessories. Install approved accessories per in- structions included with accessories. Contact your dealer for a list of approved accessories.

WARNING! Risk of Fire and Electric Shock! Use ONLY Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty.

E. Glass Rock Media Kit

NOTE: During appliance set up, gas pressure verifica- tion, or troubleshooting, do not operate appliance with glass off for more than 30 seconds to prevent the media tray from warping. Flames may curl back underneath the

media tray with glass removed.

WARNING! Choking Hazard! Keep glass rock media out of reach of children.

CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Cleaning the Glass Rock Media

During shipment of the glass rock media, dust and debris can accumulate in the rock bag. It is recommended that the glass rock media be rinsed thoroughly with water to re- move dust and small glass rock particles. An easy method to clean the glass rock media is to empty the contents of the bag into a bucket and rinse thoroughly with a garden hose. Allow the glass rock media to dry before installing into the fireplace.

Installation

1.Position rock media placement jig over pilot shield to prevent inadvertent glass rock media placement in front of pilot shield.

2.Figure 14.1 shows the outline of the media tray edges and pilot transient ports. DO NOT install glass rock media in the outlined area. This may cause delayed ignition, undesirable burner flame, or lighting issues.

A. Remove Fixed Glass Assembly WARNING

Delayed Ignition Risk

Place glass rock media according to instructions.

Do NOT place glass rock media in area in front of pilot or between burner tracks.

Do NOT place glass rock media in a position that they may fall into area in front of pilot.

Do NOT use any media other than the glass rock media supplied with this fireplace.

Do NOT use more than one 10 lb. bag of glass rock media per fireplace.

Fireplace will not function properly.

Delayed ignition may occur.

ROCK MEDIA

PLACEMENT JIG

NO GLASS ROCK

MEDIA BETWEEN

BURNER TRACKS

( INSIDE DASHED LINE)

Figure 14.1. Rock Media Placement Jig

3.Place an even layer of glass rock media around the base pan as shown in Figure 14.2. Do not place glass rock media between the inside edges of the media tray. Place entire contents of the bag onto the media tray. See Figure 14.2.

4.Remove rock placement jig by removing one screw that attaches jig to pilot shield. See Figure 14.2. Place smaller sized glass rock media on top of the pilot shield. See Figure 14.3. Do not place glass rock media in front of pilot assembly.

NO GLASS ROCK MEDIA

BETWEEN BURNER TRACKS

(INSIDE DASHED LINES)

ROCK MEDIA

PLACEMENT JIG

Figure 14.2. Installing Glass Rock Media

Heat & Glo • SLR-C2292-900 Rev. D • 8/12

57

Image 57
Contents Model SLR-CCOSMO NOTICE•What to do if you smell gas Owner’s ManualHomeowner Reference Information A. CongratulationsSafety Alert Key Table of ContentsInstaller Guide User Guide15 Troubleshooting 14 Appliance Setup = Contains updated information 13 FinishingLIMITED LIFETIME WARRANTY B. Limited Lifetime WarrantyWARRANTY COVERAGE WARRANTY PERIODWARRANTY CONDITIONS B. Limited Lifetime Warranty continuedWARRANTY EXCLUSIONS This warranty is void if1 Listing and Code Approvals D. High Altitude InstallationsA. Appliance Certification B. Tempered Glass SpecificationsInstallation of Carbon Monoxide Detectors 2 Operating Instructions User Guide A. Gas Fireplace SafetyB. Your Fireplace WARNING! Choking Hazard! Keep glass rock mediaC. Clear Space E. Fixed Glass AssemblyD. Decorative Doors and Fronts G. Before Lighting FireplaceFinal inspection by H. Lighting Instructions IPIFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONS IPII. After Fireplace is Lit J. Frequently Asked QuestionsInitial Break-inProcedure •Some people may be sensitive to smoke and odorsA. Maintenance Tasks-Homeowner 3 Maintenance and ServiceGlass Cleaning Remote ControlGasket Seal and Glass Assembly Inspection B.Maintenance Tasks-QualifiedService TechnicianFirebox Control Compartment and Firebox TopA. Typical Appliance System Getting StartedInstaller Guide WALL SWITCHB. Design and Installation Considerations C. Tools and Supplies NeededD. Inspect Appliance and Components A. Selecting Appliance Location 5 Framing and ClearancesHeat & Glo • SLR-C• 2292-900Rev. D • 8/12 B. Constructing the Appliance ChaseMINIMUM FRAMING DIMENSIONS C. ClearancesD. Mantel and Wall Projections Figure 5.8 Non-CombustibleZone Heat & Glo • SLR-C• 2292-900Rev. D • 8/123-1/2IN A. Vent Termination Minimum Clearances 6 Termination Locations= AREA WHERE TERMINAL IS NOT PERMITTED Covered Alcove ApplicationsV= VENT TERMINAL X = AIR SUPPLY INLET E. Vent Diagrams 7 Vent Information and DiagramsA. Approved Pipe B. Vent Table KeyVenting with 1 elbow Top Vent - Horizontal TerminationVenting with 2 elbows 1. Top Vent - Horizontal Termination - continuedINSTALLED HORIZONTALLY Top Vent - Horizontal Termination1. Top Vent - Horizontal Termination - continued Venting with 3 elbowsTop Vent - Horizontal Termination SLR-CINSTALLED HORIZONTALLY INSTALLED HORIZONTALLYH2 H1 V1 1. Top Vent - Horizontal Termination - continuedV1 = 44 ft. Max. 13.4 m Top Vent - Vertical Termination No ElbowsExhaust restrictor Instructions PILOT HOLESVenting with 2 elbows Top Vent - Vertical TerminationSLR-C V1 MinimumVenting with 3 elbows Top Vent - Vertical TerminationSLR-C V1 MinimumTop Vent - Vertical Termination Venting with 4 elbowsV3 H2 H1 V1 V1 MINPrior to installing the gas appliance Coaxial to Colinear VentingTable Clearances to CombustiblesTOP VENT •Vent this appliance directly outside•Use separate vent system for this appliance A. Pipe Clearances to Combustibles 8 Vent Clearances and FramingB. Wall Penetration Framing •Between ceiling firestopsC. Install the Ceiling Firestop D. Install Attic Insulation Shield Flat Ceiling InstallationVaulted Ceiling Installation A. Top Vent 9 Appliance PreparationWARNING! Risk of Fire! Prevent contact with B. Securing and Leveling the Appliance•Sagging or loose insulation •Insulation backing or plasticA. Assemble Vent Sections 10 Installing Vent Pipe SLP PipeB. Assemble Slip Sections C. Secure The Vent SectionsPilot hole D. Disassemble Vent Sections E. Install Decorative Ceiling ComponentsF. Install Metal Roof Flashing G. Assemble and Install Storm CollarCAULK I. Install Decorative Wall Components H. Install Vertical Termination CapFigure Figure 10.16 Wall ThimbleFigure 10.17 Venting through the wall K. Install Horizontal Termination Cap11 Gas Information A. Fuel ConversionB. Gas Pressure D. High Altitude Installations C. Gas ConnectionValve Pressure Taps Ensure adequate ventilationB. IntelliFire Ignition System Wiring A. Wiring RequirementsC. Optional Accessories Requirements 12 Electrical InformationE. Junction Box Installation D. Electrical Service and Repair13 Finishing A. Framing and Finishing InstructionsDrywall gypsum board Plywood Figure 13.3 Finishing Details NON-COMBUSTIBLEBOARD15-7/8IN. TO 16-1/8IN FIREPLACE OPENINGFinish and Sealing Joints Finishing Around Opening with Gypsum WallboardB. Mantel and Wall Projections C. Facing Material Non-CombustibleFinish Materials0 - 1 inch thickness-OverlapFit Method 0 Inches to 4 Inches Thick Inside Fit Method Non-CombustibleFinish MaterialsNon-CombustibleFinish Material 0-4Inches Thick 3/4 INTable 1. Dimensions of Tonic Decorative Front D. Decorative FrontsTable 1. Dimensions of Tonic Decorative Front Inside and Overlap Fit See Section 13.CA. Remove Fixed Glass Assembly 14 Appliance SetupC. Clean the Appliance D. AccessoriesPILOT SHIELD BURNER TRACKS NO GLASS ROCK MEDIA BETWEEN DASHED LINESFigure 14.4. Maintaining Media Tray Air Spaces G. Install the Mesh F. Fixed Glass AssemblyH. Air Shutter Setting Removing Fixed Glass AssemblyA. IntelliFire Ignition System 15 TroubleshootingIntelliFire Ignition System - continued 16 Reference Materials A. Appliance Dimension DiagramLocation InchesEffective Height Length B. Vent Components Diagrams6-1/2in 165 mm6-11/16in B. Vent Components Diagrams continued3-15/16in 169 mm15-1/2IN 394 mm B. Vent Components Diagrams continued7 IN 178 mm 12IN 305mmB. Vent Components Diagrams continued COAXIAL to COLINEAR VENTINGOptional Wire Harness DESCRIPTION9 in B. Vent Components Diagrams12-1/2in 2-3/4inC. Service Parts Service PartsSLR-CCOSMO Stocked#11 Valve Assembly Service PartsSLR-CCOSMO at DepotSLR-CCOSMO Service Partsat Depot StockedD. Contact Information NOTESNOTICE