Heat & Glo LifeStyle 6000GCF-IPILP owner manual Securing and Leveling the Appliance

Page 21

C. Securing and Leveling the Appliance

WARNING

Fire Risk.

Prevent contact with sagging, loose insulation.

Do NOT install against combustible materials

such as exposed insulation, plastic and insulation backer.

The diagram shows how to properly position, level, and secure the appliance (see Figure 7.4). Nailing tabs are pro- vided to secure the appliance to the framing members.

Place the appliance into position.

Level the appliance from side to side and front to back.

Shim the appliance, as necessary. It is acceptable to use wood shims.

Bend out nailing tabs on each side.

Keep nailing tabs flush with the framing.

Secure the appliance to the framing by using nails or screws through the nailing tabs.

NAILING TABS

(BOTH SIDES)

Figure 7.4 Proper Positioning, Leveling and

Securing of Appliance

WARNING

Fire Risk.

• ALWAYS maintain specified

clearances around the appliance.

• Do NOT notch into the framing around the appliance spacers.

Failure to keep insulation, framing or other material away from the appliance may cause fire.

D. Installing the Flue Restrictor

FLUE RESTRICTOR

Figure 7.5

1.Break the Flue Restrictor into two pieces. Do this by bending the part back and forth until it breaks (see Figure 7.6).

BREAK

HERE

Figure 7.6 Flue Restrictor

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. F • 6/08

21

Image 21
Contents Hot glass will cause burns Models 6000GCF-IPI6000GCF-IPILPHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Getting StartedSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseMantel Projections In. MINFt. MAX Termination Locations Vent Termination Minimum ClearancesSee .4 for specific clearances Alcove Applications Vent Table Key Vent Information and DiagramsUse of Elbows Measuring StandardsTop Vent Horizontal Termination One Elbow Vent DiagramsTwo Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows H1 Maximum V1 + Minimum H1+ H2 V1+ V2 Minimum H1+ H2 Maximum Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationNon-Combustible Wall Penetration Installing the Ceiling Firestop Installing Attic ShieldVertical Penetration Framing Temporary Access Panel Appliance PreparationAttaching Sheetrock Ledges Securing and Leveling the Appliance Installing the Flue RestrictorVertical Top Vent Installing the Fiberglass GasketAssembly of Vent Sections Installing Vent PipeAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsDisassembly of Vent Sections Securing the Vent Sections Vertical SectionsHorizontal Sections Installing Heat Shield and Horizontal Termination Cap Installing the Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Roof Pitch Min. Ft Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarFuel Conversions Gas Connection Gas InformationGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Wall Switch Recommendation for WireOptional Accessories Requirements Electrical InformationIntellifire Pilot Ignition IPI Wiring Diagram Wall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingClean the Appliance Appliance SetupAccessories Remove Shipping MaterialsInstall the Refractory Ember PlacementPlacing the Ember Material Log #1 SRV2103-107 Positioning the Logs12 Front View Air Shutter Setting Glass AssemblyScreen Mesh Grilles and TrimBefore Lighting Appliance Operating InstructionsOn position. The ON/OFF switch may Turn off all electric power to the applianceLighting Appliance IPI Ignition Final inspection byFrequently Asked Questions Initial Break-in ProcedureAfter Appliance is Lit Troubleshooting Intellifire Ignition SystemSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksAppliance Dimension Diagram Reference MaterialsLocation Inches Millimeters DVP vent components Vent Components DiagramsWall Shield Firestop Horizontal Termination CapHeat Shield Horizontal Termination Cap KitNot for use on these models Extended Heat ShieldDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Log Set Assembly Part number list on following Service PartsService Parts List StockedAt Depot 6000GCF-IPI IPI Valve AssemblyLimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information