Heat & Glo LifeStyle 6000GCF-IPILP owner manual Symptom Possible Cause Corrective Action

Page 44

Intellifire Ignition System - (continued)

Symptom

Possible Cause

Corrective Action

 

 

 

3. (Continued) Pilot lights

c. Module is not grounded.

Verify that module is securely grounded to metal chassis

but continues to spark,

 

of appliance. Verify that wire harness is firmly connected to

and main burner will not

 

module.

ignite. (If the pilot contin-

 

 

d. Damaged pilot assembly or dirty sensor

Verify that ceramic insulator around the sensor rod is not

ues to spark after the pilot

rod.

cracked, damaged, or loose. Verify connection from sensor

flame has been lit, flame

 

rod to white sensor wire. Clean sensor rod with emery cloth

rectification has not oc-

 

 

to remove any contaminants that may have accumulated

curred.)

 

 

on sensor rod. Verify continuity with a multimeter with

 

 

 

 

ohms set at lowest range.

 

 

 

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF posi-

 

 

tion. Remove ignitor wire “I” from module. Place ON/OFF

 

 

Rocker switch or wall switch in ON position. Hold ground

 

 

wire about 3/16 inch away from “I” terminal on module. If

 

 

there is no spark at “I” terminal module must be replaced.

 

 

If there is a spark at “I” terminal, module is fine. Inspect

 

 

pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

4. Pilot sparks, but Pilot

a. Correct gas supply.

Verify that incoming gas line ball valve is “open”. Verify that

will not light.

 

inlet pressure reading is within acceptable limits, inlet pres-

 

 

sure must not exceed 14 in. W.C.

 

 

 

 

b. Ignitor gap is too large.

Verify that spark gap from ignitor to pilot hood is .17 in. or

 

 

1/8 in.

 

 

 

 

c. Module is not grounded.

Verify module is securely grounded to metal chassis of

 

 

appliance.

 

 

 

 

d. Module voltage output / Valve/Pilot

Verify battery voltage is at least 2.7 volts. Replace batteries

 

solenoid ohms readings.

if voltage is below 2.7.

 

 

 

5. Pilot will not stay lit after

a. Pilot plate out of position.

Ensure pilot plate is in proper position (see Section 7).

carefully following lighting

 

 

instructions.

 

 

 

 

 

44

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. F • 6/08

Image 44
Contents Models 6000GCF-IPI6000GCF-IPILP Hot glass will cause burnsCongratulations Homeowner Reference InformationTable of Contents Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsGetting Started Tools and Supplies NeededFraming and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesFt. MAX Mantel ProjectionsIn. MIN See .4 for specific clearances Termination LocationsVent Termination Minimum Clearances Alcove Applications Vent Information and Diagrams Vent Table KeyUse of Elbows Measuring StandardsVent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Minimum MaximumTop Vent Horizontal Termination Three Elbows H1 Maximum V1 + Minimum Top Vent Vertical Termination Three Elbows H1+ H2 V1+ V2 Minimum H1+ H2 MaximumVent Clearances and Framing Pipe Clearances to CombustiblesNon-Combustible Wall Penetration Wall Penetration FramingCombustible Wall Penetration Vertical Penetration Framing Installing the Ceiling FirestopInstalling Attic Shield Attaching Sheetrock Ledges Temporary Access PanelAppliance Preparation Installing the Flue Restrictor Securing and Leveling the ApplianceInstalling the Fiberglass Gasket Vertical Top VentInstalling Vent Pipe Assembly of Vent SectionsAttaching Vent to the Firebox Assembly Assembling Pipe SectionsAssembling Minimum Installations MI Sections Assembling DVP-12A Slip SectionsHorizontal Sections Disassembly of Vent SectionsSecuring the Vent Sections Vertical Sections Heat Shield Requirements for Horizontal Termination Installing Heat Shield and Horizontal Termination CapInstalling the Horizontal Termination Cap Installing Roof Flashing and Vertical Termination Cap Roof Pitch Min. FtAssembling and Installing Storm Collar 17 Assembling the Storm Collar Around the PipeGas Information Fuel Conversions Gas ConnectionGas Pressures Pressure Natural Gas PropaneHigh Altitude Installations Recommendation for Wire Wall SwitchOptional Accessories Requirements Electrical InformationIntellifire Pilot Ignition IPI Wiring Diagram Junction Box Installation Wall Switch Installation for Fan OptionalFinishing Facing MaterialAppliance Setup Clean the ApplianceAccessories Remove Shipping MaterialsPlacing the Ember Material Install the RefractoryEmber Placement Positioning the Logs Log #1 SRV2103-10712 Front View Glass Assembly Air Shutter SettingScreen Mesh Grilles and TrimOperating Instructions Before Lighting ApplianceTurn off all electric power to the appliance On position. The ON/OFF switch mayLighting Appliance IPI Ignition Final inspection byAfter Appliance is Lit Frequently Asked QuestionsInitial Break-in Procedure Sympton Possible Cause Corrective Action TroubleshootingIntellifire Ignition System Symptom Possible Cause Corrective Action Maintenance Tasks Maintaining and Servicing ApplianceInspect Maintenance Tasks Doors, SurroundsLocation Inches Millimeters Appliance Dimension DiagramReference Materials Vent Components Diagrams DVP vent componentsHorizontal Termination Cap Wall Shield FirestopHeat Shield Horizontal Termination Cap KitExtended Heat Shield Not for use on these modelsDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Service Parts Log Set Assembly Part number list on followingAt Depot Service Parts ListStocked IPI Valve Assembly 6000GCF-IPILimited Lifetime Warranty Limited Lifetime Warranty Heat & GLO GAS Appliance ProductsContact Information Do not Discard this Manual