Heat & Glo LifeStyle 6000GCF-IPILP owner manual Troubleshooting, Intellifire Ignition System

Page 43

14 Troubleshooting

With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service. If you do experience a problem, this troubleshooting guide will assist a qualified service person in the diagnosis of a problem and the corrective action to be taken. This troubleshooting guide can only be used by a qualified service technician.

A. Intellifire Ignition System

Sympton

Possible Cause

Corrective Action

 

 

 

1. The ignitor/module

a. Incorrect wiring.

Verify “S” wire (white) for sensor and “I” wire (orange) for ignitor

makes noise, but no

 

are connected to correct terminals on module and pilot assembly.

spark.

 

Reversed wires at the module may cause system to make sparking

 

 

noise, but spark may not be present at pilot hood.

 

 

 

 

b. Loose connections or electrical

Verify no loose connections or electrical shorts in wiring from mod-

 

shorts in the wiring.

ule to pilot assembly. Rod closest to pilot hood should be ignitor.

 

 

Verify connections underneath pilot assembly are tight; also verify

 

 

connections are not grounding out to metal chassis, pilot burner,

 

 

pilot enclosure, mesh screen if present, or any other metal object.

 

 

 

 

c. Ignitor gap is too large.

Verify gap of igniter to pilot hood. The gap should be approximately

 

 

.17 inch or 1/8 inch.

 

 

 

 

d. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF Rocker switch or wall

 

 

switch in ON position. Hold ground wire about 3/16 inch away from

 

 

“I” terminal on module. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

2. Pilot won’t light,

a. Transformer installed correctly.

Verify that transformer is installed and plugged into module. Check

there is no noise or

 

voltage of transformer under load at spade connection on module

spark.

 

with ON/OFF switch in ON position. Acceptable readings of a good

 

 

transformer are between 3.2 and 2.8 volts AC.

 

 

 

 

b. A shorted or loose connection in wir-

Remove and reinstall the wiring harness that plugs into module.

 

ing configuration or wiring harness.

Verify there is a tight fit. Verify pilot assembly wiring to module.

 

 

Remove and verify continuity of each wire in wiring harness.

 

 

 

 

c. Improper wall switch wiring.

Verify that 110/VAC power is “ON” to junction box.

 

 

 

 

d. Module not grounded.

Verify black ground wire from module wire harness is grounded to

 

 

metal chassis of appliance.

 

 

 

 

e. Faulty module.

Turn ON/OFF rocker switch or wall switch to OFF position. Remove

 

 

ignitor wire “I” from module. Place ON/OFF Rocker switch or wall

 

 

switch in ON position. Hold ground wire about 3/16 inch away from

 

 

“I” terminal on module. If there is no spark at “I” terminal module

 

 

must be replaced. If there is a spark at “I” terminal, module is fine.

 

 

Inspect pilot assembly for shorted sparker wire or cracked insulator

 

 

around electrode.

 

 

 

3. Pilot lights but con-

a. A shorted or loose connection in

Verify all connections to wiring diagram in manual. Verify connec-

tinues to spark, and

sensor rod.

tions underneath pilot assembly are tight. Verify connections are

main burner will not ig-

 

not grounding out to metal chassis, pilot burner, pilot enclosure or

nite. (If the pilot contin-

 

screen if present, or any other metal object.

ues to spark after the

 

 

b. Poor flame rectification or contami-

Verify that flame is engulfing sensor rod. If the pilot assembly does

pilot flame has been lit,

flame rectification has

nated sensor rod.

not have a ground strap, consider installing one to increase flame

 

rectification. Verify correct pilot orifice is installed and inlet gas

not occurred.)

 

 

specifications. Flame carries rectification current, not the gas. If

 

 

 

 

flame lifts from pilot hood, the circuit is broken. A wrong orifice or

 

 

too high an inlet pressure can cause pilot flame to lift. The sensor

 

 

rod may be contaminated. Clean sensor rod with emery cloth.

 

 

 

Heat & Glo • 6000GCF-IPI, 6000GCF-IPILP2110-900 Rev. F • 6/08

43

Image 43
Contents Hot glass will cause burns Models 6000GCF-IPI6000GCF-IPILPHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsTools and Supplies Needed Getting StartedSelecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseIn. MIN Mantel ProjectionsFt. MAX Vent Termination Minimum Clearances Termination LocationsSee .4 for specific clearances Alcove Applications Measuring Standards Vent Information and DiagramsVent Table Key Use of ElbowsMinimum Maximum Vent DiagramsTop Vent Horizontal Termination One Elbow Two ElbowsTop Vent Horizontal Termination Three Elbows H1 Maximum V1 + Minimum H1+ H2 V1+ V2 Minimum H1+ H2 Maximum Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingCombustible Wall Penetration Wall Penetration FramingNon-Combustible Wall Penetration Installing Attic Shield Installing the Ceiling FirestopVertical Penetration Framing Appliance Preparation Temporary Access PanelAttaching Sheetrock Ledges Securing and Leveling the Appliance Installing the Flue RestrictorVertical Top Vent Installing the Fiberglass GasketAssembling Pipe Sections Installing Vent PipeAssembly of Vent Sections Attaching Vent to the Firebox AssemblyAssembling DVP-12A Slip Sections Assembling Minimum Installations MI SectionsSecuring the Vent Sections Vertical Sections Disassembly of Vent SectionsHorizontal Sections Installing the Horizontal Termination Cap Installing Heat Shield and Horizontal Termination CapHeat Shield Requirements for Horizontal Termination Roof Pitch Min. Ft Installing Roof Flashing and Vertical Termination Cap17 Assembling the Storm Collar Around the Pipe Assembling and Installing Storm CollarPressure Natural Gas Propane Gas InformationFuel Conversions Gas Connection Gas PressuresHigh Altitude Installations Electrical Information Recommendation for WireWall Switch Optional Accessories RequirementsIntellifire Pilot Ignition IPI Wiring Diagram Wall Switch Installation for Fan Optional Junction Box InstallationFacing Material FinishingRemove Shipping Materials Appliance SetupClean the Appliance AccessoriesEmber Placement Install the RefractoryPlacing the Ember Material Log #1 SRV2103-107 Positioning the Logs12 Front View Grilles and Trim Glass AssemblyAir Shutter Setting Screen MeshBefore Lighting Appliance Operating InstructionsFinal inspection by Turn off all electric power to the applianceOn position. The ON/OFF switch may Lighting Appliance IPI IgnitionInitial Break-in Procedure Frequently Asked QuestionsAfter Appliance is Lit Intellifire Ignition System TroubleshootingSympton Possible Cause Corrective Action Symptom Possible Cause Corrective Action Maintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramLocation Inches Millimeters DVP vent components Vent Components DiagramsHorizontal Termination Cap Kit Horizontal Termination CapWall Shield Firestop Heat ShieldNot for use on these models Extended Heat ShieldDVP-HRC-SS DVP-HRC-ZC-SS Horizontal Termination CAP Log Set Assembly Part number list on following Service PartsStocked Service Parts ListAt Depot 6000GCF-IPI IPI Valve AssemblyLimited Lifetime Warranty Heat & GLO GAS Appliance Products Limited Lifetime WarrantyDo not Discard this Manual Contact Information