Vermont Casting DVRTSB manual Twist Lock Venting Components

Page 20

DVRTSB Bay Window Fireplace

Twist Lock Venting Components

Starter Kit-Model 7TDVSK-Sidewall/Rearwall Venting Starter Kit-Model 7TDVSKV-Vertical Venting

for 7TDVSKV-A order 1/12 to 6/12 roof pitch for 7TDVSKV-B order 7/12 to 12/12 roof pitch for 7TDSKV-F order flat roof

Starter Kit-Model 7TDVSKS-Snorkel Kit for Below Grade Installation

45˚ Elbow

7TDV45 for Rear Vent to Vertical Vent or Vertical/Horizontal Offsets

90˚ Transition Elbow

7TDVRT90 for Rear Vent to Vertical Vent

90° Elbow

7TDV90 Vertical/Horizontal Offset

Telescopic vent sections

 

 

 

 

7TDVP1218

-12” to 18” adjustible length

 

 

 

 

7TDVP3564

-35” to 64” adjustible length

 

 

 

 

 

 

 

 

 

 

 

 

 

Pipe sections for vertical or horizontal venting

 

 

 

 

Model 7TDVP8”

4 per box

 

 

 

 

Model 7TDVP12”

4 per box

 

 

 

 

Model 7TDVP24”

4 per box

 

 

 

 

 

 

 

 

Model 7TDVP36”

 

 

 

 

 

Model 7TDVP48”

 

Firestop Spacer

Model 7DVFS

Attic Insulation Shield

Model 7DVAIS

Vertical/Horizontal Combination Offset Support

Model 7DVCS

7TBSG 7”T.L. DVRTSB Termination Screen Guard Kit

20

10003848

Image 20
Contents Homeowner’s Installation Operating Manual Table of Contents Installation & Operating Instructions National Fuel Gas Code Ansi Z223.1/NFPADvrtsb Top Vent Fireplace Dimensions Installed as Top VentFraming Dimensions Fireplace Dimensions Installed as Rear Vent Dvrtsb Rear VentLocating Your Fireplace Clearance to CombustiblesMantels HearthGas Line Installation Final FinishingGas Specifications Gas Inlet and Manifold PressuresEB-1 Electrical Box Remote ON/OFF Switch InstallationAlternate Switch Location Optional Top Vent Application Remove flue cover and flue pipeGeneral Venting Information Termination Location Location of Vent TerminationCanadian Installations1 US Installations2 Termination location requirementsGeneral Information for Connecting Vent Pipes Canadian InstallationsUSA Installations Twist Lock PipesHow to Use the Vent Graph Rear Wall Vent InstallationRear Wall Vent Applications Example aVertical Sidewall Applications Zero clearance sleeve is only required for combustible wallsVertical Sidewall Installation Maximum vent run with elbowsAlways install horizontal venting on a level plane Horizontal length requirementBelow Grade Installation Vertical Through-the-Roof ApplicationsVertical Through-The-Roof Installation Enlarged ends of the vent section always face downwardAttic Insulation Shield Upper Floor Twist Lock Venting Components Glass Information Louvre RemovalGlass/Frame Removal Side Glass FrameGlass Cleaning Ceramic Refractory InstallationInstallation of Logs Clean the glass after the first two weeks of operationFlame Characteristics Flame & Temperature Adjustment Lava Rock & Ember MaterialCeramic Ember Rocks Pt. # RN/RP ModelsLighting and Operating Instructions To Turn Off Gas To HeaterTroubleshooting the Gas Control System Honeywell Millivolt Valve Fuel Conversion Instructions SIT top Convertible PilotPSE Pilot SIT 820 Nova Gas Control Valve FigBrass Trim Cleaning the Standing Pilot Control SystemBurner and Burner Compartment Description OFFDvrtsb Dvrtsb Bay Window Fireplace Fan Kits Remote Controls ON/OFF and TemperatureModel Function/s Controlled Wall mounted thermostat controlDvrtsb Bay Window Fireplace Limited Lifetime Warranty Efficiency Ratings