Vermont Casting DVRTSB manual Dvrtsb Bay Window Fireplace

Page 31

 

 

 

DVRTSB Bay Window Fireplace

DVRTSB (continued)

 

 

 

 

 

 

Ref.

Description

DVRTSB

39.

Louvre Assembly, Front Bottom

10003880

40.

Hinge, Lower Louvre Assembly

52356

41.

Window Frame Assembly Side

10003859

42.

Window Frame Assembly Front

10003843

43.

Window Glass (Complete with Gasket), Side (not shown)

10003860

44.

Window Glass (Complete with Gasket), Front (not shown)

55686

45.

Gasket Glass (not shown)

57317

46.

Window Frame Clamp

54174

47.

Refractory Lining (Rear Wall Left)

10003887

48.

Refractory Lining (Rear Wall Right)

10003888

49.

Refractory Lining (Floor Left)

10003890

50.

Refractory Lining (Floor Right)

10003891

51.

Refractory Lining (Floor Front)

10003892

52.

CR Floor Kit w/o Rear

10003889

53.

Air Inlet Cover Plate Assembly (not shown)

10002766

54.

Air Inlet Plate Gasket (not shown)

10002449

55.

Flue Pipe Plate Assembly (not shown)

10002509

56.

Flue Pipe Plate Gasket (not shown)

10002237

57.

Flue Cover Plate (not shown)

10002298

58.

Flue Cover Plate Gasket (not shown)

10002233

59.

Relief Plate (w/Gasket) (not shown)

10002543

60.

Deflector, Cabinet Top Front (not shown)

10002260

61.

Deflector, Cabinet Top Side (not shown)

10003869

62.

Trim Window Top/Bottom

54129-PB

63.

Trim Window Side

10003234

10003848

31

Image 31
Contents Homeowner’s Installation Operating Manual Table of Contents National Fuel Gas Code Ansi Z223.1/NFPA Installation & Operating InstructionsFraming Dimensions Fireplace Dimensions Installed as Top VentDvrtsb Top Vent Dvrtsb Rear Vent Fireplace Dimensions Installed as Rear VentHearth Locating Your FireplaceClearance to Combustibles MantelsGas Inlet and Manifold Pressures Gas Line InstallationFinal Finishing Gas SpecificationsAlternate Switch Location Remote ON/OFF Switch InstallationEB-1 Electrical Box Remove flue cover and flue pipe Optional Top Vent ApplicationLocation of Vent Termination General Venting Information Termination LocationTermination location requirements Canadian Installations1 US Installations2Twist Lock Pipes General Information for Connecting Vent PipesCanadian Installations USA InstallationsExample a How to Use the Vent GraphRear Wall Vent Installation Rear Wall Vent ApplicationsZero clearance sleeve is only required for combustible walls Vertical Sidewall ApplicationsMaximum vent run with elbows Vertical Sidewall InstallationHorizontal length requirement Always install horizontal venting on a level planeVertical Through-the-Roof Applications Below Grade InstallationEnlarged ends of the vent section always face downward Vertical Through-The-Roof InstallationAttic Insulation Shield Upper Floor Twist Lock Venting Components Side Glass Frame Glass InformationLouvre Removal Glass/Frame RemovalClean the glass after the first two weeks of operation Glass CleaningCeramic Refractory Installation Installation of LogsRN/RP Models Flame Characteristics Flame & Temperature AdjustmentLava Rock & Ember Material Ceramic Ember Rocks Pt. #To Turn Off Gas To Heater Lighting and Operating InstructionsTroubleshooting the Gas Control System Honeywell Millivolt Valve SIT 820 Nova Gas Control Valve Fig Fuel Conversion InstructionsSIT top Convertible Pilot PSE PilotBurner and Burner Compartment Cleaning the Standing Pilot Control SystemBrass Trim OFF DescriptionDvrtsb Dvrtsb Bay Window Fireplace Fan Kits Wall mounted thermostat control Remote ControlsON/OFF and Temperature Model Function/s ControlledDvrtsb Bay Window Fireplace Limited Lifetime Warranty Efficiency Ratings