Vermont Casting DVRTSB manual Optional Top Vent Application, Remove flue cover and flue pipe

Page 9

Optional Top Vent Application

This appliance is shipped as a rear vent unit. If the installation layout requires the unit to be a top vent con- figuration the appliance can be converted by following the steps below.

When removing and refitting the plates and adapter be sure the associated gaskets are undamaged and refitted as required.

1.

Remove the 10 screws securing the outer collar

 

adapter to the fireplace body. (Fig. 9)

2.

Set the collar aside, complete with the gasket. Do not

 

damage the gasket as the adapter and gasket must

DVRTSB Bay Window Fireplace

Insulation

Flue

Cover

Flue

Pipe

Remove

Screws (4)

be refitted.

3. Remove all of the insulation material (exposed in

Step 2) from the top of the unit. (Fig. 10) This

Remove Screws (4)

Fig. 10 Remove flue cover and flue pipe.

FP1027

material can be discarded, however if the unit is con- verted back to rear vent for any reason a new piece of insulation material approved by CFM Corporation must be used for this purpose.

4.Remove the four (4) screws securing the flue cover plate to the top of the intake box and remove the cover and gasket. (Fig. 11)

5.Remove four (4) screws securing the flue pipe to back of the intake box and remove pipe and gasket. (Fig. 11)

6.Secure the plate and gasket removed in Step 4 over the flue opening in the back of the intake box. Ensure the gasket is in place and undamaged.

7.Install the flue pipe and gasket removed in Step 5 over the flue opening in the top of the intake box.

8.Refit the outer collar adapter and gasket to the unit with the round collar on the top. Secure the adapter with the 10 screws removed in Step 1.

When converting the appliance to top vent, ensure the insulation material referred to in Step 3 is com- pletely removed.

Rear View

Outer Col- lar Adapter

Flue

Pipe

Remove Screws

(5)

Remove

 

Screws (5)

FP1030

 

Fig. 9 Remove screws from outer collar adapter.

Flue Cover Plate

Flue

Pipe

FP1378

Fig. 11 Remove flue pipe and flue cover plate.

10003848

9

Image 9
Contents Homeowner’s Installation Operating Manual Table of Contents National Fuel Gas Code Ansi Z223.1/NFPA Installation & Operating InstructionsFireplace Dimensions Installed as Top Vent Framing DimensionsDvrtsb Top Vent Dvrtsb Rear Vent Fireplace Dimensions Installed as Rear VentClearance to Combustibles Locating Your FireplaceMantels HearthFinal Finishing Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresRemote ON/OFF Switch Installation Alternate Switch LocationEB-1 Electrical Box Remove flue cover and flue pipe Optional Top Vent ApplicationLocation of Vent Termination General Venting Information Termination LocationTermination location requirements Canadian Installations1 US Installations2Canadian Installations General Information for Connecting Vent PipesUSA Installations Twist Lock PipesRear Wall Vent Installation How to Use the Vent GraphRear Wall Vent Applications Example aZero clearance sleeve is only required for combustible walls Vertical Sidewall ApplicationsMaximum vent run with elbows Vertical Sidewall InstallationHorizontal length requirement Always install horizontal venting on a level planeVertical Through-the-Roof Applications Below Grade InstallationEnlarged ends of the vent section always face downward Vertical Through-The-Roof InstallationAttic Insulation Shield Upper Floor Twist Lock Venting Components Louvre Removal Glass InformationGlass/Frame Removal Side Glass FrameCeramic Refractory Installation Glass CleaningInstallation of Logs Clean the glass after the first two weeks of operationLava Rock & Ember Material Flame Characteristics Flame & Temperature AdjustmentCeramic Ember Rocks Pt. # RN/RP ModelsTo Turn Off Gas To Heater Lighting and Operating InstructionsTroubleshooting the Gas Control System Honeywell Millivolt Valve SIT top Convertible Pilot Fuel Conversion InstructionsPSE Pilot SIT 820 Nova Gas Control Valve FigCleaning the Standing Pilot Control System Burner and Burner CompartmentBrass Trim OFF DescriptionDvrtsb Dvrtsb Bay Window Fireplace Fan Kits ON/OFF and Temperature Remote ControlsModel Function/s Controlled Wall mounted thermostat controlDvrtsb Bay Window Fireplace Limited Lifetime Warranty Efficiency Ratings