Vermont Casting DVRTSB manual Fireplace Dimensions Installed as Rear Vent, Dvrtsb Rear Vent

Page 5

DVRTSB Bay Window Fireplace

 

Fireplace Dimensions (Installed as Rear Vent)

 

 

G

G

 

 

F

F

 

 

E

 

 

 

 

Gas

 

 

 

Line

EB1 Box

 

 

Inlet

 

 

Inlet

 

 

2³⁄"

 

 

4¹⁄"

 

K - Rough Opening Depth

(60mm)

 

(105mm)

 

 

 

M - Rough Opening Width

 

 

 

 

5⁷⁄₁₆"

3⁷⁄"

 

Rough

(138mm)

(99mm)

 

H

J

 

Opening

 

Height

 

 

 

 

 

I

 

L

A

 

 

 

 

 

 

B

 

 

 

 

7/8" Dia.

 

 

 

1¹⁄" Dia.

 

 

C

 

 

 

D

3848

 

 

 

Fig. 3

Fireplace specifications and framing dimensions.

 

 

Ref.

DVRTSB (Rear Vent)

A

35”

(888 mm)

B

34³⁄

(873 mm)

C

32³⁄

(831 mm)

D

34⁷⁄

(885 mm)

E

2¹⁄

(56 mm)

F

2”

(51 mm)

G

17¹⁄

(444 mm)

H

24”

(610 mm)

I

5³⁄

(139 mm)

J

2³⁄

(61 mm)

 

Framing Dimensions

K

 

24” (609 mm) minus one finishing material

 

 

thickness to be even with face of unit

L

 

35¹⁄” (895 mm)

M

 

35” (888 mm) minus twice the finishing material

 

 

thickness to be even with face of unit.

10003848

5

Image 5
Contents Homeowner’s Installation Operating Manual Table of Contents National Fuel Gas Code Ansi Z223.1/NFPA Installation & Operating InstructionsDvrtsb Top Vent Fireplace Dimensions Installed as Top VentFraming Dimensions Dvrtsb Rear Vent Fireplace Dimensions Installed as Rear VentClearance to Combustibles Locating Your FireplaceMantels HearthFinal Finishing Gas Line InstallationGas Specifications Gas Inlet and Manifold PressuresEB-1 Electrical Box Remote ON/OFF Switch InstallationAlternate Switch Location Remove flue cover and flue pipe Optional Top Vent ApplicationLocation of Vent Termination General Venting Information Termination LocationTermination location requirements Canadian Installations1 US Installations2Canadian Installations General Information for Connecting Vent PipesUSA Installations Twist Lock PipesRear Wall Vent Installation How to Use the Vent GraphRear Wall Vent Applications Example aZero clearance sleeve is only required for combustible walls Vertical Sidewall ApplicationsMaximum vent run with elbows Vertical Sidewall InstallationHorizontal length requirement Always install horizontal venting on a level planeVertical Through-the-Roof Applications Below Grade InstallationEnlarged ends of the vent section always face downward Vertical Through-The-Roof InstallationAttic Insulation Shield Upper Floor Twist Lock Venting Components Louvre Removal Glass InformationGlass/Frame Removal Side Glass FrameCeramic Refractory Installation Glass CleaningInstallation of Logs Clean the glass after the first two weeks of operationLava Rock & Ember Material Flame Characteristics Flame & Temperature AdjustmentCeramic Ember Rocks Pt. # RN/RP ModelsTo Turn Off Gas To Heater Lighting and Operating InstructionsTroubleshooting the Gas Control System Honeywell Millivolt Valve SIT top Convertible Pilot Fuel Conversion InstructionsPSE Pilot SIT 820 Nova Gas Control Valve FigBrass Trim Cleaning the Standing Pilot Control SystemBurner and Burner Compartment OFF DescriptionDvrtsb Dvrtsb Bay Window Fireplace Fan Kits ON/OFF and Temperature Remote ControlsModel Function/s Controlled Wall mounted thermostat controlDvrtsb Bay Window Fireplace Limited Lifetime Warranty Efficiency Ratings