Fuel Conversion Instructions
The conversion of this appliance from one gas to another must be carried out by a qualified service technician.
1. | Disconnect power to unit and shut off the gas supply. |
2. | Remove the glass (Refer to “Glass Removal” Sec- |
DVRTSB Bay Window Fireplace
b. Unscrew the exposed conversion screw.
c. Insert the new color coded conversion screw. Do not
d. Refit the regulator cap.
e. Mount conversion label supplied with conversion screw to valve in a visible position.
| tion.) |
3. | Carefully remove the logs & lava rock material. |
4. | Remove the screws that are holding the burner |
| housing in place. |
5. | Remove the burner housing. On this model you may |
| need to loosen the pilot bracket retaining screw/nut |
| and tilt pilot and bracket assembly to gain sufficient |
| clearance to remove the burner housing. |
6. | Remove front and rear orifice and replace with ori- |
| fice supplied in the conversion kit. |
7. | SIT top Convertible Pilot |
| Gently lift off pilot hood from the pilot. (Do not |
| remove the spring clip holding the hood in place). |
| Using a size 5/32” Allen key unscrew the exposed |
| orifice. Insert the new orifice supplied in the kit, do |
| not over tighten the orifice. Replace the pilot hood |
| ensuring the index tab aligns with the notch on the |
A
B
C
| OFF |
| P |
| I |
O | TOL |
FC107
E
| OFF | |
| P | |
|
| I |
O | TO | L |
F
D
FC108
hood. |
PSE Pilot |
Using a suitable wrench on hexagonal body unscrew |
the pilot hood assembly from the pilot, do not twist |
the hood itself. Remove the orifice and replace it |
with the new orifice supplied in the kit. Refit the pilot |
hood assembly. Do not |
The hood must return to its original alignment. Take |
care not to damage the thermocouple, thermopile or |
igniter. |
8. SIT 820 NOVA Gas Control Valve (Fig. 11) |
a) Using a Torx T20 or slotted screwdriver, remove |
and save three pressure regulator mounting screws |
(A), pressure regulator tower (B) and diaphram (C). |
b) Ensure the rubber gasket (D) is properly posi- |
tioned and install the new HI/LO pressure regulator |
to valve using the new screws (E) supplied with the |
kit. Tighten screws securely. (Reference torque - 25 |
in.LB) |
c) Install the enclosed identification label (F) to the |
valve body where it can be easily seen. |
Honeywell Gas Control Valve (Fig. 12)
The Honeywell valve fitted to this unit is suitable for use with LP or Natural Gas. It is converted to re- quired gas application by the installation of a color coded “conversion screw”.
a. Using a suitable small
Fig. 45 NOVA SIT820 gas valve.
9. Reassemble |
|
| |
fireplace in | Regulator Cap | Conversion | |
the reverse | |||
| |||
| Screw | ||
order, except |
| ||
|
| ||
for front |
| L | |
glass. Leave | I | ||
HO |
| ||
|
| ||
this off until |
| Pressure | |
| Regulator | ||
after unit |
| Housing | |
has been |
|
| |
checked for |
|
| |
leaks and |
|
| |
the gas sup- |
|
| |
ply has been |
|
| |
bled. |
|
| |
10. After bleed- |
| HV102 | |
ing gas line | Fig. 46 Honeywell gas valve. | ||
and check- |
|
|
ing for leaks with a soap solution, replace the front glass. Fire up the unit, check for flame impingment on logs, adjusting them if necessary. Check manifold and supply pressures. Make sure screws are tight- ened after checking pressure.
The procedure for converting from one gas to another is the same regardless of the initial gas used. The only variation is in the orifice sizes and component part numbers. Your authorized service provider will en- sure correct parts are used.
10003848 | 27 |