GENERAL MAINTENANCE
Spider/Insect screens
Your VieluxeTM Gas Barbecue, as well as any outdoor gas appliance, is a target for spiders and other insects. They can nest in the venturi section Venturi(1) of the burner tubes. This blocks the normal gas flow, and can cause the gas to flow back out of the air shutter. Figure 5. This could result in a fire in and around the air shutters, under the control panel, causing serious damage to your barbecue.
(1)
The burner tube air shutter is fitted with a stainless steel screen(1) to prevent spiders and other insects access to the burner tubes through the air shutter openings.
We recommend that you inspect the Spider/Insect screens at least once a year. Also inspect and clean the Spider/Insect screens if any of the following symptoms should ever occur.
1.The smell of gas in conjunction with the burner flames appearing yellow and lazy.
2.Barbecue does not reach temperature.
3.Barbecue heats unevenly.
4.One or more of the burners do not ignite.
DANGER
Failure to correct these symptoms may result in a fire which can cause serious bodily injury or death and cause damage to property.
Inspection and cleaning of the
Spider/Insect screens
To inspect the spider/insect screens, remove the control panel. If there is dust or dirt on the screens, remove the burners for cleaning the screens. Refer to Maintenance, Replacing Main Burners. Brush the spider/inspect screens, lightly, with a soft bristle brush (i.e. an old toothbrush).
Caution: Do not clean the spider/insect screens with hard or sharp tools. Do not dislodge the spider/insect screens or enlarge the screen openings.
Lightly tap the burner to get debris and dirt out of the burner tube. Once the spider/insect screens and burners are clean replace the burners.
If the spider/insect screen becomes damaged or cannot be cleaned, call Customer Service toll free at 1 (866) VIELUXE.