Regency L676S-NG1 Vent Restrictor Position, Vent Restrictor Plate Latch, No adjustment required

Page 15

INSTALLATION

VENT RESTRICTOR POSITION

Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation.

The Vent Restrictor plate is located on the inside top of the firebox.

Vent Restrictor Plate

Latch

2- ½”

b. Swing the door out from the top and release

Vent Restrictor Set 1

the hinge on the left side of the door and

 

lift out.

Factory Set Vent Restrictor Set

 

(no adjustment required)

INSTALLATION

To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions;

1) Remove the faceplate.

2)Remove the glass door.

2”

Vent Restrictor Set 2

a.Release the 2 door latches on the left and right side at the top of the firebox.

Latch Location

HingeDoor

3) Remove the screws that hold the vent

1- 1/4

restrictor plate in place.

 

 

4)Adjust the vent restrictor plate to the required vent restrictor position as per the diagrams shown.

Vent Restrictor Set 3

5)Once the vent restrictor plate is in the required position, secure with screws.

Screws for plugging the holes.

(all holes must be plugged with a screw).

Screw holes for fixing the restrictor plate.

Regency® L676S Direct Vent Gas Fireplace

15

Image 15
Contents L676 Sunrise Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Factory Equipped For Altitude 0-4500ft -1372m Safety LabelCopy of Safety Decal Serial No. / No de serieFor the State of Massachusetts only RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeat Release KIT Finished FloorClearances Mantel LEG Clearances Mantel ClearancesFraming Installed. See Diagram 3 for detailsFraming Important Header must be metal stud. All other framing mayFinishing Non-combustibleMaterial + 3/4 + 3/8Unit Assembly Prior to Installation Finishing TemplateVenting Introduction Latch Location HingeDoor No adjustment requiredVent Restrictor Position Vent Restrictor Plate LatchExterior Vent Termination Requirements Minimum Clearance RequirementsCanada1 Horizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor On SetVertical Vent Restrictor On Set Option + V1 H + H1 Option + H1+ H1 V + V1 With these options, max. total OptionAllowable Vertical Terminations Unit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Unit InstallationHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingOptional Aeration AdjustmentWiring Diagram Minimum Air Shutter OpeningLP Conversion Kit Contains Qty Description Conversion KIT #526-969 from NG to LPLeaks Slots on fl oor of fi rebox base Panel InstallationStainless Steel Panels Black Enamel Panels Firebox baseHoles on bottom Panel Left panelUse this hole on panel clip Spread the supplied Glass Crystals or optional Ceramic Spa Location of mounting brackets Faceplate & Door Frame InstallationAdjustment for fi nishing materials Level adjustmentOperating Instructions Lighting Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Copy of Lighting Plate InstructionsMaintenance DC Spark Box Location DC Spark BOX Battery ReplacementDC Spark BOX Replacement DC Spark Box WiresValve Tray Replacement Door Hinge with door removedSlots for back panel Valve Tray Out Disconnect 2 wiresDC Spark Box Electrode Wire Location of Screws Disconnect 2 generator wiresMain Assembly Parts ListHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information