Regency L676S-NG1 installation manual Conversion KIT #526-969 from NG to LP

Page 30

INSTALLATION

CONVERSION KIT #526-969 FROM NG TO LP

THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!

INSTALLATION

LP Conversion Kit Contains:

Qty.

Part #

Description

1

910-101

Orifice SIT Pilot LP #35

1

910-037

LP Pilot Orifice

1

908-528

Red Propane Label

1

904-345

Orifice #53

1

904-529

Allen Key 5/32

1

918-590

LP Conversion Decal

1

918-764

Instruction Sheet

1906-182 4 x 6 Ziplock Case.

1)Remove the faceplate (see page 35).

2)Remove the glass door.

a. Release the 2 door latches on the left and right side at the top of the firebox.

Latch Location

Latch

b. Swing the door out from the top and release the hinge on the left side of the door and lift out off hinge.

Hinge with door removed.

c.Place the door on a soft surface to prevent scratching.

3)Lift off the Pilot Shield Cover Plate to expose 2 bolts.

Pilot Shield Cover Plate

Bolts

4)Remove the 2 bolts to release the burner.

6)Remove the burner orifice with a 1/2" wrench. Use another wrench to hold onto the elbow behind the orifice. Replace the NG burner orifice with LP orifice #53.

Burner Orifi ce

7)Remove the NG pilot orifice with the 5/32 Allen Key and replace with LP pilot orifice.

8)Reinstall the pilot cap.

Pilot Cap

5) Carefully lift out burner.

Door

30

Regency® L676S Direct Vent Gas Fireplace

Image 30
Contents L676 Sunrise Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Serial No. / No de serie Safety LabelCopy of Safety Decal Factory Equipped For Altitude 0-4500ft -1372mRequirements For the State of Massachusetts onlyUnit Dimensions Installation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsFinished Floor Manufactured Mobile Home Additional RequirementsHeat Release KIT Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesImportant Header must be metal stud. All other framing may Installed. See Diagram 3 for detailsFraming FramingFinishing Non-combustibleMaterial + 3/8 + 3/4Unit Assembly Prior to Installation Finishing TemplateVenting Introduction Vent Restrictor Plate Latch No adjustment requiredVent Restrictor Position Latch Location HingeDoorExterior Vent Termination Requirements Minimum Clearance RequirementsCanada1 Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor On SetVertical Vent Restrictor On Set Option + H1 Option + V1 H + H1Option + H1 V + V1 With these options, max. totalAllowable Vertical Terminations Unit Installation with Horizontal Termination Diagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Astrocap XLGAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationMinimum Air Shutter Opening Aeration AdjustmentWiring Diagram OptionalConversion KIT #526-969 from NG to LP LP Conversion Kit Contains Qty DescriptionLeaks Firebox base Panel InstallationStainless Steel Panels Black Enamel Panels Slots on fl oor of fi rebox baseHoles on bottom Panel Left panelUse this hole on panel clip Spread the supplied Glass Crystals or optional Ceramic Spa Level adjustment Faceplate & Door Frame InstallationAdjustment for fi nishing materials Location of mounting bracketsOperating Instructions Copy of Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Lighting InstructionsMaintenance DC Spark Box Wires DC Spark BOX Battery ReplacementDC Spark BOX Replacement DC Spark Box LocationValve Tray Replacement Door Hinge with door removedSlots for back panel Location of Screws Disconnect 2 generator wires Disconnect 2 wiresDC Spark Box Electrode Wire Valve Tray OutParts List Main AssemblyHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information