Regency L676S-NG1 Manufactured Mobile Home Additional Requirements, Heat Release KIT

Page 8

INSTALLATION

INSTALLATION

9)Test Gas Pressure (Refer to "Gas Pipe Pres- sure Testing" section).

10)Install standard and optional features. Refer to the following sections:

a)Inside Panels

b)Glass Crystals or Ceramic Stones

c)Remote Control - refer to "Matching Remote Handset & Control Box ID Code" section.

d)Outer Faceplate

11)Final check.

Before leaving this unit with the customer, the installer must ensure that the appliance is firing correctly and operation fully explained to customer.

This includes:

1)Clocking the appliance to ensure the correct firing rate (rate noted on label 29,000 (NG) Btu/h, 26,000 (LP) Btu/h) after burning appliance for 15 minutes.

2)If required, adjusting the primary air to ensure that the flame does not carbon. First allow the unit to burn for 15-20 min. to stabilize.

CAUTION: Any alteration to the product that causes sooting or carboning that results in damage is not the responsibility of the manufacturer.

MANUFACTURED

MOBILE HOME

ADDITIONAL

REQUIREMENTS

3)The L676S Direct Vent Gas Fireplace can be installed in a recessed position or framed out into the room as in A, B, C and D. See Diagram 1.

A) Flat on Wall

B)Flat on Wall Corner

C)Recessed into

Wall/Alcove

D) Corner

Diagram 1

4)This appliance is Listed for bedroom installations using the standard Remote (millivolt thermostat system). Some areas may have further requirements, check local codes before installation.

5)The L676S Direct Vent Gas Fireplace is approved for alcove installations, see "Clearances" section for details.

6)We recommend that you plan your installation on paper using exact measurements for clearances and floor protection before actually installing this appliance. Have an authorized inspector, dealer, or installer review your plans before installation.

Note: For vent terminations refer to "Exterior Vent Termination Locations" section.

HEAT RELEASE KIT

The Heat Release Kit expels warm air from the fireplace to the outside of the building, allowing the fireplace to be operated with less heat entering the room. The kit may be used on either the left or right side.

See Heat Release installation manual for complete details and clearances from side only.

FINISHED FLOOR

The maximum height that combustible floor can be brought above the base of the unit is 0".

Note: If finished floor is any higher than the base of the unit, the facepate will not fit into place.

1)Ensure that structural members are not cut or weakened during installation.

2)Ensure proper grounding using the #8 ground lug provided. See "Wiring Diagram" section.

LOCATING YOUR

GAS FIREPLACE

1)When selecting a location for your fireplace, ensure that the clearances are met.

2)The appliance must be installed on a flat, solid, continuous surface (e.g. wood, metal, concrete).This may be the floor, or raised up on a platform to enhance its visual impact. The appliance must be installed on a metal or wood panel extending the full width and depth of the appliance.

HEATWAVE

DUCT KIT

The HeatWave Air Duct Kit increases the effectiveness of your fireplace by dispersing warm air from the fireplace to remote locations in the same room or other rooms in your home.

Up to two kits may be installed on the fireplace. Please Note: Only 1 HeatWave kit may be operated at one time.

See HeatWave installation manual for complete details and clearances from side only.

The HeatWave Duct Kit has different clearance and framing requirements, check the HeatWave manual for details.

8

Regency® L676S Direct Vent Gas Fireplace

Image 8
Contents L676 Sunrise Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalSerial No. / No de serie Factory Equipped For Altitude 0-4500ft -1372mRequirements For the State of Massachusetts onlyUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Heat Release KITFinished Floor Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesInstalled. See Diagram 3 for details FramingImportant Header must be metal stud. All other framing may FramingMaterial FinishingNon-combustible + 3/8 + 3/4Venting Introduction Unit Assembly Prior to InstallationFinishing Template No adjustment required Vent Restrictor PositionVent Restrictor Plate Latch Latch Location HingeDoorCanada1 Exterior Vent Termination RequirementsMinimum Clearance Requirements Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart Installation Vertical Vent Restrictor On Set Allowable Horizontal TerminationsVent Restrictor On Set Option + H1 Option + V1 H + H1Option + H1 V + V1 With these options, max. totalAllowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLPilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationAeration Adjustment Wiring DiagramMinimum Air Shutter Opening OptionalConversion KIT #526-969 from NG to LP LP Conversion Kit Contains Qty DescriptionLeaks Panel Installation Stainless Steel Panels Black Enamel PanelsFirebox base Slots on fl oor of fi rebox baseUse this hole on panel clip Holes on bottom PanelLeft panel Spread the supplied Glass Crystals or optional Ceramic Spa Faceplate & Door Frame Installation Adjustment for fi nishing materialsLevel adjustment Location of mounting bracketsOperating Instructions For Your Safety Read Before Lighting Normal Operating Sounds GAS AppliancesCopy of Lighting Plate Instructions Lighting InstructionsMaintenance DC Spark BOX Battery Replacement DC Spark BOX ReplacementDC Spark Box Wires DC Spark Box LocationSlots for back panel Valve Tray ReplacementDoor Hinge with door removed Disconnect 2 wires DC Spark Box Electrode WireLocation of Screws Disconnect 2 generator wires Valve Tray OutParts List Main AssemblyHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information