Regency L676S-NG1 installation manual + 3/8, + 3/4

Page 13

INSTALLATION

To accommodate various thicknesses of facing material - the faceplate is adjustable to a maximum of 1-1/4" and a minimum of 1/2" .

See chart below and page 35 for detailed instructions.

Finished Facing Thickness

Faceplate Adjustment

 

 

1/2"

Factory Setting

 

 

 

1/2" - 7/8" (or less)

Adjusted to

+ 3/8"

 

 

 

7/8" - 1-1/4" (or less)

Adjusted to

+ 3/4"

 

 

 

Diagram 5

INSTALLATION

Regency® L676S Direct Vent Gas Fireplace

13

Image 13
Contents L676 Sunrise Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Copy of Safety Decal Safety LabelSerial No. / No de serie Factory Equipped For Altitude 0-4500ft -1372mFor the State of Massachusetts only RequirementsUnit Dimensions General Safety Information InstallationInstallation Checklist Important Message Save These InstructionsHeat Release KIT Manufactured Mobile Home Additional RequirementsFinished Floor Locating Your GAS FireplaceClearances Mantel LEG Clearances Mantel ClearancesFraming Installed. See Diagram 3 for detailsImportant Header must be metal stud. All other framing may FramingNon-combustible FinishingMaterial + 3/4 + 3/8Finishing Template Unit Assembly Prior to InstallationVenting Introduction Vent Restrictor Position No adjustment requiredVent Restrictor Plate Latch Latch Location HingeDoorMinimum Clearance Requirements Exterior Vent Termination RequirementsCanada1 Horizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Vent Restrictor On Set Allowable Horizontal TerminationsVertical Vent Restrictor On Set Option + V1 H + H1 Option + H1+ H1 V + V1 With these options, max. total OptionAllowable Vertical Terminations Unit Installation with Horizontal Termination This allows for small adjustments Unit Installation With Vertical TerminationDiagram Minimum VentAstrocap XL Unit InstallationGAS Line Installation Pilot AdjustmentGAS Pipe Pressure Testing High ElevationWiring Diagram Aeration AdjustmentMinimum Air Shutter Opening OptionalLP Conversion Kit Contains Qty Description Conversion KIT #526-969 from NG to LPLeaks Stainless Steel Panels Black Enamel Panels Panel InstallationFirebox base Slots on fl oor of fi rebox baseLeft panel Holes on bottom PanelUse this hole on panel clip Spread the supplied Glass Crystals or optional Ceramic Spa Adjustment for fi nishing materials Faceplate & Door Frame InstallationLevel adjustment Location of mounting bracketsOperating Instructions Normal Operating Sounds GAS Appliances For Your Safety Read Before LightingCopy of Lighting Plate Instructions Lighting InstructionsMaintenance DC Spark BOX Replacement DC Spark BOX Battery ReplacementDC Spark Box Wires DC Spark Box LocationDoor Hinge with door removed Valve Tray ReplacementSlots for back panel DC Spark Box Electrode Wire Disconnect 2 wiresLocation of Screws Disconnect 2 generator wires Valve Tray OutMain Assembly Parts ListHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information