You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The L676S has been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch. The model L676S has been approved by Warnock Hersey for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow. Please take a moment now to acquaint yourself with these instructions and the many features of your Regency® Fireplace.

MANUFACTURED MOBILE HOME REQUIREMENTS

INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE

This Regency® product has been tested and listed by Warnock Hersey as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88a-2007 / CSA 2.33a-2007 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91.

This DirectVent System Appliance must be installed in accordance with the manufacturer's installation instructions and the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard of Fire Safety Criteria for Manufactured Home Installations, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240-MH Mobile Home Standard in Canada.

This appliance installation must comply with the manufacturer's installation instructions and local codes, if any. In the absence of local codes follow the current National Fuel Gas Code, ANSI Z223.1 and the current National Electrical Code ANSI/NFPA 70 in the U.S.A., and the current CAN/CGA B149 Gas Installation Code and the current Canadian Electrical Code CSA C22.1 in Canada.

This appliance comes equipped with a dedicated #8 Ground Lug for attachment of the ground wire to the steel chassis as applicable to local codes.

The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1.

This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.A only) or mobile home, where not prohibited by local codes.

This appliance can only be used with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used. (Kit# 526-969)

Ensure that structural members are not cut or weakened during installation.

2

Regency® L676S Direct Vent Gas Fireplace

Image 2
Contents L676 Sunrise Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Serial No. / No de serie Safety LabelCopy of Safety Decal Factory Equipped For Altitude 0-4500ft -1372mRequirements For the State of Massachusetts onlyUnit Dimensions Installation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsFinished Floor Manufactured Mobile Home Additional RequirementsHeat Release KIT Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesImportant Header must be metal stud. All other framing may Installed. See Diagram 3 for detailsFraming FramingMaterial FinishingNon-combustible + 3/8 + 3/4Venting Introduction Unit Assembly Prior to InstallationFinishing Template Vent Restrictor Plate Latch No adjustment requiredVent Restrictor Position Latch Location HingeDoorCanada1 Exterior Vent Termination RequirementsMinimum Clearance Requirements Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart Installation Vertical Vent Restrictor On Set Allowable Horizontal TerminationsVent Restrictor On Set Option + H1 Option + V1 H + H1Option + H1 V + V1 With these options, max. totalAllowable Vertical Terminations Unit Installation with Horizontal Termination Diagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Astrocap XLGAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationMinimum Air Shutter Opening Aeration AdjustmentWiring Diagram OptionalConversion KIT #526-969 from NG to LP LP Conversion Kit Contains Qty DescriptionLeaks Firebox base Panel InstallationStainless Steel Panels Black Enamel Panels Slots on fl oor of fi rebox baseUse this hole on panel clip Holes on bottom PanelLeft panel Spread the supplied Glass Crystals or optional Ceramic Spa Level adjustment Faceplate & Door Frame InstallationAdjustment for fi nishing materials Location of mounting bracketsOperating Instructions Copy of Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Lighting InstructionsMaintenance DC Spark Box Wires DC Spark BOX Battery ReplacementDC Spark BOX Replacement DC Spark Box LocationSlots for back panel Valve Tray ReplacementDoor Hinge with door removed Location of Screws Disconnect 2 generator wires Disconnect 2 wiresDC Spark Box Electrode Wire Valve Tray OutParts List Main AssemblyHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information