UNIT ASSEMBLY

PRIOR TO

INSTALLATION

The Top Facing Support, the Side Nailing Strips and the 2 Top Standoffs must be correctly positioned and attached to the top before unit is slipped into position.

SIDE NAILING STRIPS

The side nailing strips come attached to the unit. There are 2 plates on each side, one on the top and bottom that can be folded out as required.

The Finishing Template uses two magnets to attach itself to the flange on the left or right side of the unit (see diagram below). Install the facing material up to the outside edge (when facing the unit) of the finishing template. This template may be discarded after the facing material has been installed.

TOP STANDOFF ASSEMBLY

The top standoffs are shipped in a flat position and must be folded into shape and attached.

1)Remove the standoffs from the fireplace

top.

2) Take each standoff and bend into the correct shape. Bend up at the bend lines until the screw holes in the standoff and the pre- punched screw holes on the fireplace top line up.

3) Attach the standoff securely to the top with 2 screws per standoff (on opposite corners).

Side Nailing Strips shown folded out.

Finishing

Template

Left Side Flange

FINISHING TEMPLATE

In order to maintain a clean face; the L676S allows for a 1/8” in overlap of finishing material, such as rock or tile, on both the left and right hand sides of the unit (top and bottom sides do not allow for an overlap), this overlap must not be exceeded or the glass door will no longer open properly.

Non-combustible wall board is installed up to the flanges on all sides of the unit. When installing any additional facing material use the Finishing Template (included with the unit) to ensure that the finishing material does not exceed the allowable overlap.

VENTING

INTRODUCTION

The L676S uses the "balanced flue" technology Co Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney.

Note: These flue pipes must not be connected to any other appliance.

The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas burning appliance. Each direct vent gas appliance must use it's own separate vent system. Common vent systems are prohibited.

14

Regency® L676S Direct Vent Gas Fireplace

Image 14
Contents L676 Sunrise Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Serial No. / No de serie Safety LabelCopy of Safety Decal Factory Equipped For Altitude 0-4500ft -1372mRequirements For the State of Massachusetts onlyUnit Dimensions Installation Checklist InstallationGeneral Safety Information Important Message Save These InstructionsFinished Floor Manufactured Mobile Home Additional RequirementsHeat Release KIT Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesImportant Header must be metal stud. All other framing may Installed. See Diagram 3 for detailsFraming FramingMaterial FinishingNon-combustible + 3/8 + 3/4Venting Introduction Unit Assembly Prior to InstallationFinishing Template Vent Restrictor Plate Latch No adjustment requiredVent Restrictor Position Latch Location HingeDoorCanada1 Exterior Vent Termination RequirementsMinimum Clearance Requirements Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart Installation Vertical Vent Restrictor On Set Allowable Horizontal TerminationsVent Restrictor On Set Option + H1 Option + V1 H + H1Option + H1 V + V1 With these options, max. totalAllowable Vertical Terminations Unit Installation with Horizontal Termination Diagram Unit Installation With Vertical TerminationThis allows for small adjustments Minimum VentUnit Installation Astrocap XLGAS Pipe Pressure Testing Pilot AdjustmentGAS Line Installation High ElevationMinimum Air Shutter Opening Aeration AdjustmentWiring Diagram OptionalConversion KIT #526-969 from NG to LP LP Conversion Kit Contains Qty DescriptionLeaks Firebox base Panel InstallationStainless Steel Panels Black Enamel Panels Slots on fl oor of fi rebox baseUse this hole on panel clip Holes on bottom PanelLeft panel Spread the supplied Glass Crystals or optional Ceramic Spa Level adjustment Faceplate & Door Frame InstallationAdjustment for fi nishing materials Location of mounting bracketsOperating Instructions Copy of Lighting Plate Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Lighting InstructionsMaintenance DC Spark Box Wires DC Spark BOX Battery ReplacementDC Spark BOX Replacement DC Spark Box LocationSlots for back panel Valve Tray ReplacementDoor Hinge with door removed Location of Screws Disconnect 2 generator wires Disconnect 2 wiresDC Spark Box Electrode Wire Valve Tray OutParts List Main AssemblyHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information