Regency L676S-NG1 installation manual Leaks

Page 31

INSTALLATION

8)Turn control knob to the “OFF” position.

9)Remove the black protection cap by hand from the high-low knob (Fig.1).

Fig.1

10)Insert a 5/32” or 4mm Allen wrench into the hexagonal key-way of the screw (Fig. 2), rotate it counter-clockwise until it is free and extract it.

13)Using the Allen wrench as shown in Fig.4, rotate the screw clockwise until snug, do not overtighten.

Fig.4

WARNING!

Do not overtighten the screw. Recommended to grip

the wrench by the short side.

14)Verify that if the conversion is from NG to LPG, the screw must be re-assembled with the red o-ring visible (Fig. 5).

16)Install the enclosed identification label to the valve body where it can be easily seen.

17)Attach the LP conversion decal near or on top of the serial no. decal.

18)Replace yellow "Natural Gas" label with red "Propane" label.

19)Adjust the burner aeration setting to the LP setting (5/16") and

re-install the burner tube.

20)Re-install the burner.

21)Re-install the Pilot Shield cover plate.

22)Re-install the glass door.

23)Re-install the faceplate

24)Continue with completing unit installation.

NOTE: Once the unit has been installed;

a) Turn on the gas supply and check for gas

leaks.

b) Check the inlet and outlet pressures.

INSTALLATION

Red o-ring visible

LPG Configuration

c) Check operation of flame control using

the remote control.

d) Check for proper flame appearance.

Fig.2

11)Check that the screw is clean and if necessary remove dirt.

12)Flip the screw (Fig. 3).

Fig.3

Fig.5

15)Re-assemble the black protection cap (Fig. 6).

Fig.6

WARNING!

Also check that the pilot and

main burner injectors

are appropriate for the gas type.

Installer Notice:

These instructions must be left with the appliance.

Regency® L676S Direct Vent Gas Fireplace

31

Image 31
Contents L676 Sunrise Gas Fireplace Information for MOBILE/MANUFACTURED Homes After First Sale Manufactured Mobile Home RequirementsTable of Contents Factory Equipped For Altitude 0-4500ft -1372m Safety LabelCopy of Safety Decal Serial No. / No de serieFor the State of Massachusetts only RequirementsUnit Dimensions Important Message Save These Instructions InstallationGeneral Safety Information Installation ChecklistLocating Your GAS Fireplace Manufactured Mobile Home Additional RequirementsHeat Release KIT Finished FloorClearances Mantel LEG Clearances Mantel ClearancesFraming Installed. See Diagram 3 for detailsFraming Important Header must be metal stud. All other framing mayNon-combustible FinishingMaterial + 3/4 + 3/8Finishing Template Unit Assembly Prior to InstallationVenting Introduction Latch Location HingeDoor No adjustment requiredVent Restrictor Position Vent Restrictor Plate LatchMinimum Clearance Requirements Exterior Vent Termination RequirementsCanada1 Horizontal Termination Flex Venting ArrangementsBasic Horizontal & Vertical Terminations Rigid Pipe Venting Systems8 Rigid Pipe Cross Reference Chart Installation Vent Restrictor On Set Allowable Horizontal TerminationsVertical Vent Restrictor On Set Option + V1 H + H1 Option + H1+ H1 V + V1 With these options, max. total OptionAllowable Vertical Terminations Unit Installation with Horizontal Termination Minimum Vent Unit Installation With Vertical TerminationThis allows for small adjustments DiagramAstrocap XL Unit InstallationHigh Elevation Pilot AdjustmentGAS Line Installation GAS Pipe Pressure TestingOptional Aeration AdjustmentWiring Diagram Minimum Air Shutter OpeningLP Conversion Kit Contains Qty Description Conversion KIT #526-969 from NG to LPLeaks Slots on fl oor of fi rebox base Panel InstallationStainless Steel Panels Black Enamel Panels Firebox baseLeft panel Holes on bottom PanelUse this hole on panel clip Spread the supplied Glass Crystals or optional Ceramic Spa Location of mounting brackets Faceplate & Door Frame InstallationAdjustment for fi nishing materials Level adjustmentOperating Instructions Lighting Instructions For Your Safety Read Before LightingNormal Operating Sounds GAS Appliances Copy of Lighting Plate InstructionsMaintenance DC Spark Box Location DC Spark BOX Battery ReplacementDC Spark BOX Replacement DC Spark Box WiresDoor Hinge with door removed Valve Tray ReplacementSlots for back panel Valve Tray Out Disconnect 2 wiresDC Spark Box Electrode Wire Location of Screws Disconnect 2 generator wiresMain Assembly Parts ListHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Conditions WarrantyInstaller Please complete the following information