Regency L676S-NG1 installation manual Safety Label, Copy of Safety Decal, Serial No. / No de serie

Page 4

INSTALLATION

SAFETY LABEL

This is a copy of the label that accompanies

each L676S-NG1 and L676S-LP1 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review.

NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.

COPY OF SAFETY DECAL

For the State of Massachusetts, installation and repair must be done by a plumber or gasfitter licensed in the Commonwealth of Massachusetts.

For the State of Massachusetts, flexible connectors shall not exceed 36 inches in length.

For the State of Massachusetts, the appli-

ances individual manual shut-off must be a t-handle type valve.

The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm with battery back up in the same room where the gas appliance is installed.

342

DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTE`

342

Serial No. / No de serie

Listed: VENTED GAS FIREPLACE HEATER

Tested to: ANSI Z21.88a-2007/ CSA 2.33a-2007,

CAN/CGA-2.17-M91

Certified for / Certifiée pour: CANADA AND U.S.A.

WN # 16074

 

NATURAL GAS FIREPLACE: MODEL L676S-NG1

L676SNG1- Model/Modele:

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

5“

WC

(1.25 kpa)

 

 

Low Setting Man. Pressure

1.6"

WC

(0.39 kpa)

 

Max. Manifold Pressure

3.5"

WC

(0.87 kpa)

 

Orifice Size

#37

DMS

 

 

Minimum Input

19,500

Btu/h

(5.71 kW)

 

Maximum Input

29,000

Btu/h

(8.49 kW)

 

PROPANE GAS FIREPLACE: MODEL L676S-LP1

L676SLP1- Model/Modele:

Factory Equipped For Altitude 0-4500ft. (0-1372m)

Min. Supply Pressure

12"

WC

(2.98 kpa)

 

 

Low Setting Man. Pressure

6.4"

WC

(1.59 kpa)

 

Max. Manifold Pressure

10"

WC

(2.49 kpa)

 

Orifice Size

#53

DMS

 

 

Minimum Input

21,000

Btu/h

(6.15 kW)

 

Maximum Input

26,000

Btu/h

(7.61 kW)

VENTED GAS FIREPLACE HEATER

This appliance must be installed in accordance with the manufacturer’s installation instructions and with local codes, if any; if none, follow the current ANSI Z223.1 in the USA or the current CAN 1-B149 in Canada.

This vented gas fireplace heater is not for use with air filters.

For Manufactured Home Installation: This Direct Vent System Appliance must be installed in accordance with the manufacturer's installation instructions and Manufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, and Communities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard in Canada.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used (Kit #526-969).

Certified for use with Heat Wave (Kit #946-556).

For use with glass doors certified with the appliance only.

Electrical Supply: 6.0 VDC

NOT FOR USE WITH SOLID FUEL

Minimum Clearances to Combustibles from Fireplace Opening

Side Walls

*A

14-3/4" (375mm)

 

 

Ceiling

B

52"

(813mm)

 

B

D

F

Min. Mantel Height

C

16-1/2" (419mm)

 

 

 

Max. Mantel Depth

**D

13”

(330mm)

 

A

Alcove Width

E

84"

(2134mm)

 

C

 

Alcove Depth

F

36"

(914mm)

 

 

Finished Floor

G

3”

(76mm)

G

 

 

 

 

 

 

E

Refer to Manual for complete Clearance Details

*Alcove side wall must have a min. of 14-3/4” (375mm) clearance on one side.

**Mantel depth taken at 26-1/2” (673mm) from front facing.

FPI Fireplace Products International Ltd., Delta BC, CANADA

 

MADE IN CANADA / FABRIQUE AU CANADA

918-760

4

Regency® L676S Direct Vent Gas Fireplace

Image 4
Contents L676 Sunrise Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalSerial No. / No de serie Factory Equipped For Altitude 0-4500ft -1372mRequirements For the State of Massachusetts onlyUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Heat Release KITFinished Floor Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesInstalled. See Diagram 3 for details FramingImportant Header must be metal stud. All other framing may FramingNon-combustible FinishingMaterial + 3/8 + 3/4Finishing Template Unit Assembly Prior to InstallationVenting Introduction No adjustment required Vent Restrictor PositionVent Restrictor Plate Latch Latch Location HingeDoorMinimum Clearance Requirements Exterior Vent Termination RequirementsCanada1 Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart Installation Vent Restrictor On Set Allowable Horizontal TerminationsVertical Vent Restrictor On Set Option + H1 Option + V1 H + H1Option + H1 V + V1 With these options, max. totalAllowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLPilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationAeration Adjustment Wiring DiagramMinimum Air Shutter Opening OptionalConversion KIT #526-969 from NG to LP LP Conversion Kit Contains Qty DescriptionLeaks Panel Installation Stainless Steel Panels Black Enamel PanelsFirebox base Slots on fl oor of fi rebox baseLeft panel Holes on bottom PanelUse this hole on panel clip Spread the supplied Glass Crystals or optional Ceramic Spa Faceplate & Door Frame Installation Adjustment for fi nishing materialsLevel adjustment Location of mounting bracketsOperating Instructions For Your Safety Read Before Lighting Normal Operating Sounds GAS AppliancesCopy of Lighting Plate Instructions Lighting InstructionsMaintenance DC Spark BOX Battery Replacement DC Spark BOX ReplacementDC Spark Box Wires DC Spark Box LocationDoor Hinge with door removed Valve Tray ReplacementSlots for back panel Disconnect 2 wires DC Spark Box Electrode WireLocation of Screws Disconnect 2 generator wires Valve Tray OutParts List Main AssemblyHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information