Regency L676S-NG1 installation manual Operating Instructions

Page 36

OPERATING INSTRUCTIONS

OPERATION

OPERATING

INSTRUCTIONS

1)Read and understand these instructions before operating this appliance.

2)Check to see that all wiring is correct and enclosed to prevent possible shock.

3)Check to ensure there are no gas leaks.

4)Make sure the glass in the door frame is properly positioned. Never operate the appliance with the glass removed.

5)Verify that the venting and cap are unobstructed.

6)The unit should never be turned off, and on again without a minimum of a 60 second wait.

MATCHING REMOTE

CONTROL & RECEIVER

CODE

(OPTIONAL)

The Remote Control Handset has a set of unique ID codes that is pre-programmed into its memory. This set of ID codes helps to differentiate one Remote Control Handset from another so that only the control box with a matching ID code will respond to the appropriate Remote Control Handset.

To ensure the remote control is matched to the receiver correctly, please follow the steps below:

LIGHTING

PROCEDURE

IMPORTANT

To ignite or reignite the pilot, you must first remove the glass door.

NOTE: The Gas ON/OFF knob cannot be turned from "ON", "PILOT" or "OFF" unless it is partially depressed.

1)Ensure the 3-way switch on the wall mounted receiver is in the "OFF" position.

2)Turn the gas control knob so the indicator points to the "OFF" position and wait 5 min- utes for any gas in the combustion chamber to escape.

3)Turn the gas control knob counterclockwise so the indicator points to the "PILOT" position. Depress the gas control knob fully. Depress the igniter button until the pilot lights. After approximately one minute, release the gas control knob.The pilot flame should continue to burn.

Only when the pilot holds, without pressure being applied to the gas control knob, re-install the glass door to the unit. The unit must not be operated without the glass door in place.

If the pilot does not remain lit, repeat opera- tion allowing a longer period before releasing gas control knob.

4)When the pilot stays lit, turn the gas control knob to the "ON" position.

5)Use the wall switch or optional remote control to turn the unit ON.

NOTE: When using the optional remote control refer to the remote manual.

FIRST FIRE

The FIRST FIRE in your heater is part of the paint curing process. To ensure the paint is properly cured, it is recommended you burn your fireplace for at least four (4) hours the first time.

When first operated, the unit will release an odour caused by the curing of the paint and the burning off of any oils remaining from manufac- turing. Smoke detectors in the house may go off at this time. Open a few windows to ventilate the room for a couple of hours. The glass may require cleaning.

NOTE: When the glass is cold and the appliance is lit, it may cause condensation and fog the glass. This condensation is normal and will disappear in a few minutes as the glass heats up.

DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS STILL HOT!

DO NOT BURN THE UNIT WITHOUT THE GLASS DOOR IN PLACE.

During the first few fires, a white film may develop on the glass front as part of the curing process. The glass should be cleaned after the unit has cooled down or the film will bake on and become very difficult to remove. Use a non-abrasive cleaner and DO NOT ATTEMPT TO CLEAN THE GLASS WHILE IT IS HOT.

1)Install 4 "AA" batteries into the receiver.

2)Turn the 3-way switch on the receiver to the "Remote" position.

3)Using a small pointy object (ie. the end of a paper clip) press the button marked "PRG" on the receiver.The receiver will beep 3 times to indicate that it is ready to synchronize with the remote control.

4)Install 3 "AAA' batteries into the remote con- trol and push the "ON" button. The receiver will beep 4 times to indicate the remote control's command has been accepted and sets to the particular code of that remote control.

SHUTDOWN

PROCEDURE

1)Turn the 3-way switch on the wall mounted receiver to the "OFF" position.

2)Press "OFF" on the remote control.

3)Turn the gas control knob to the "OFF" posi- tion to turn off the pilot.

36

Regency® L676S Direct Vent Gas Fireplace

Image 36
Contents L676 Sunrise Gas Fireplace Manufactured Mobile Home Requirements Information for MOBILE/MANUFACTURED Homes After First SaleTable of Contents Safety Label Copy of Safety DecalSerial No. / No de serie Factory Equipped For Altitude 0-4500ft -1372mRequirements For the State of Massachusetts onlyUnit Dimensions Installation General Safety InformationInstallation Checklist Important Message Save These InstructionsManufactured Mobile Home Additional Requirements Heat Release KITFinished Floor Locating Your GAS FireplaceClearances Mantel Clearances Mantel LEG ClearancesInstalled. See Diagram 3 for details FramingImportant Header must be metal stud. All other framing may FramingFinishing Non-combustibleMaterial + 3/8 + 3/4Unit Assembly Prior to Installation Finishing TemplateVenting Introduction No adjustment required Vent Restrictor PositionVent Restrictor Plate Latch Latch Location HingeDoorExterior Vent Termination Requirements Minimum Clearance RequirementsCanada1 Venting Arrangements Horizontal Termination FlexRigid Pipe Venting Systems Basic Horizontal & Vertical Terminations8 Rigid Pipe Cross Reference Chart Installation Allowable Horizontal Terminations Vent Restrictor On SetVertical Vent Restrictor On Set Option + H1 Option + V1 H + H1Option + H1 V + V1 With these options, max. totalAllowable Vertical Terminations Unit Installation with Horizontal Termination Unit Installation With Vertical Termination This allows for small adjustmentsDiagram Minimum VentUnit Installation Astrocap XLPilot Adjustment GAS Line InstallationGAS Pipe Pressure Testing High ElevationAeration Adjustment Wiring DiagramMinimum Air Shutter Opening OptionalConversion KIT #526-969 from NG to LP LP Conversion Kit Contains Qty DescriptionLeaks Panel Installation Stainless Steel Panels Black Enamel PanelsFirebox base Slots on fl oor of fi rebox baseHoles on bottom Panel Left panelUse this hole on panel clip Spread the supplied Glass Crystals or optional Ceramic Spa Faceplate & Door Frame Installation Adjustment for fi nishing materialsLevel adjustment Location of mounting bracketsOperating Instructions For Your Safety Read Before Lighting Normal Operating Sounds GAS AppliancesCopy of Lighting Plate Instructions Lighting InstructionsMaintenance DC Spark BOX Battery Replacement DC Spark BOX ReplacementDC Spark Box Wires DC Spark Box LocationValve Tray Replacement Door Hinge with door removedSlots for back panel Disconnect 2 wires DC Spark Box Electrode WireLocation of Screws Disconnect 2 generator wires Valve Tray OutParts List Main AssemblyHeat Wave Kit Release Kit Burner Assembly Regency L676S Direct Vent Gas Fireplace Regency L676S Direct Vent Gas Fireplace Warranty ConditionsInstaller Please complete the following information